Ei Electronics Ei166 - Manuals
Ei Electronics Ei166 – Manual in PDF format online.
Manuals:
Manual Ei Electronics Ei166
Summary
brown: liveblue: neutral The wire which is coloured blue must be connected to the terminal/wire which is marked with the letter N or colouredblack. The wire which is coloured brown must be connected to the terminal/wire which is marked with the letter L or coloured red. The apparatus is not to be ea...
2. Testing your System After Installation 1. Turn on the AC mains power to the smoke alarm circuit. Check the continuous green light is visible on the smoke alarmcover. The red light on the unit will flash every 40 seconds. 2. Plug in the control panel mains adaptor (or turn on the AC mains if it is...
5. Product Guarantee Ei Electronics guarantees this system for 5 years from the date of purchase against any defects that are due to faulty materi-als or workmanship. This guarantee only applies to normal condi-tions of use and service, and does not include damage resultingfrom accident, neglect, mi...