Page 2 - Special symbols
614-40095-00 2 Special symbols The following are examples of symbols used on the UPS or accessories to alert you to important information: DANGER: Dangerous voltage levels are present within the UPS. The UPS has its own internal power source (the battery). Consequently, the power outlets may be ener...
Page 3 - Table of Contents
614-40095-00 3 Table of Contents 1 Introduction ................................................................................................................... 5 1.1 Environmental protection ............................................................................................................
Page 5 - Introduction; Environmental protection; Substances
614-40095-00 5 •• • 1 Introduction Thank you for selecting an Eaton 5PX product to protect your electrical equipment. The Eaton 5PX range has been designed with the utmost care. We recommend that you take the time to read this advanced user guide to take full advantage of the many features of your U...
Page 6 - End of life; Battery
614-40095-00 6 Materials Abbreviations Number in the symbols Polyethylene terephthalate PET 01 High-density polyethylene HDPE 02 Polyvinyl chloride PVC 03 Low-density polyethylene LDPE 04 Polypropylene PP 05 Polystyrene PS 06 Follow all local regulations for the disposal of packing materials. End of...
Page 7 - Presentation; Standard installation
614-40095-00 7 2 Presentation 2.1 Standard installation Tower installation Rack installation Weights and dimensions Description (UPS) Weights (lb / kg) Dimentions (inch / mm) D x W x H 5PX1000RTG25PX1000RTNG2 44.5 / 20.2 17.6x17.2x3.4 / 448x438x85.5 5PX1500RTG25PX1500RTNG2 50.7 / 23.0 17.6x17.2x3.4 ...
Page 9 - Optional accessories; Installation; Inspecting the equipment
614-40095-00 9 1.2. 2.3 Optional accessories Part number Description 5PXEBM48RTG25PXEBM72RTG25PXEBM72RT3UAG2 Extended Battery Module Network-M2 Eaton Gigabit Network Card (SNMP v1/v3 and IP v4/v6 // Ethernet 10/100/1000BaseT) INDGW-M2 Eaton Industrial Gateway Card (Modbus TCP / RTU) Relay-MS Eaton R...
Page 10 - Package content
614-40095-00 10 Package content Verify that the following additional items are included with the UPS: ① UPS ⑬ Connection cable to AC power source ⑮ RS232 communication cable ⑯ USB communication cable ⑰ Safety instructions ⑱ Quick start ⑳ Rack kit for 19-inch 4-post enclosures ㉑ Two supports for...
Page 11 - Recommended positions; Installation in tower position
614-40095-00 11 3.2 Recommended positions Installation in tower position If you ordered other UPS accessories, refer to specific user manuals to check the tower installation with the UPS. To install the UPS: Place the UPS on a flat, stable surface in its final location. Always keep 6" or 150 mm ...
Page 12 - Installation in rack position
614-40095-00 12 Installation in rack position Follow steps 1 to 4 for module mounting on the rails. The rails and necessary hardware are supplied by Eaton.
Page 13 - Connecting the internal battery
614-40095-00 13 1. 2.3. 3.3 Connecting the internal battery A small amount of arcing may occur when connecting the internal batteries. This is normal and will not harm personnel. Connect the cables quickly and firmly. Remove the front panel by pressing on both sides of the panel.Connect the two batt...
Page 16 - HotSwap MBP module operation
614-40095-00 16 1. Connect the input socket (48) on the HotSwap MBP module to the AC power source. 2. Connect the UPS input power cord (13) to the receptacle "UPS Input" (47) of the HotSwap MBP module. 3. Connect the "UPS Output" cable (46) of the HotSwap MBP module to the outlet ...
Page 17 - Interfaces and communication; Led indicator
614-40095-00 17 4 Interfaces and communication 4.1 Control panel The screen provides useful information about the UPS itself, load status, events, measurements and settings. The LED bar ⑨ has been implemented to provide a quick visual reference of UPS status "at-a-glance". ① Power ON indicat...
Page 19 - Display functions; Menu map for display functions
614-40095-00 19 4.3 Display functions Press the Enter ( ⮠ ) button to activate the menu options. Use the two middle buttons ( ⯅ and ⯆ ) to scroll through the menu structure. Press the Enter ( ⮠ ) button to select an option. Press the ( ESC ) button to cancel or return to the previous menu. Me...
Page 24 - Communication ports
614-40095-00 24 Submenu Available settings Default settings [DB9-7]: [On bat] [Low bat] [Bat fault] [UPS OK] [Load protected] [Load powered] [General alarm] [OVL pre-alarm] [DB9-8]: [On bat] [Low bat] [Bat fault] [UPS OK] [Load protected] [Load powered] [General alarm] [OVL pre-alarm] Remote command...
Page 25 - Connection of RS232/USB communication port; Characteristics of the contact RS232 communication port
614-40095-00 25 1. 2. ••• Connection of RS232/USB communication port Connect the RS232 (15) or USB (16) communication cable to the serial or USB port on the computer equipment.Connect the other end of the communication cable (15) or (16) to the USB (5) or RS232 (6) communication port on the UPS. Th...
Page 26 - Installation of the communication cards; UPS remote control functions; Connectivity cards
614-40095-00 26 1.2.3. • • • • Installation of the communication cards It is not necessary to shutdown the UPS before installing a communication card. Remove the slot cover (9) secured by screws.Insert the communication card in the slot. Secure the card cover with the two screws to connect the comm ...
Page 27 - Programmable signal inputs
614-40095-00 27 • • ••• Programmable signal inputs The 5PX incorporates several programmable signal inputs: one Remote Power Off (RPO) input terminal, one Remote On/ Off (ROO) input terminal, one RS-232 input (pin-4). Signal inputs can be configured (see Settings > Comm settings > Signal Input...
Page 28 - Programmable signal outputs
614-40095-00 28 • 1.2.3. 4.5.6. On/Off control via button has priority over the remote control. The ROO function is only active after the first use of the "Remote OFF" function. ROO Comments Connector type Terminal, 14 AWG Maximum wires Terminal rating 60 V DC/30 V AC 20 mA max Remote contr...
Page 29 - Eaton Intelligent Power Software suite; Operation; Battery charge
614-40095-00 29 Signal Default assignment Description OVL pre-alarm - Overload pre-alarm Bat disconn - Battery is disconnected (1) Relay output: 4.7 Eaton Intelligent Power Software suite Eaton Intelligent Power Software suite is available from eaton.com/downloads . Eaton Software suite provides up-...
Page 30 - Starting the UPS on battery; Normal mode
614-40095-00 30 1. 2. •• AC-power disturbance If AC power is disturbed or fails, the UPS continues to operate on battery power. In normal mode, the audio alarm beeps every ten seconds, then every three seconds when the end of battery backup time is near. If the power outage lasts longer than the bat...
Page 31 - End of battery backup time; Return of AC input power; Retrieving the event log; Retrieving the fault log; UPS maintenance; Storing the equipment
614-40095-00 31 ••• 1.2. 1.2. End of battery backup time LCD displays "End of backup time".All the LEDs go OFF.The audible alarm stops. 5.5 Return of AC input power Following an outage, the UPS restarts automatically when AC input power returns (unless the restart function has been disabled)...
Page 32 - When to replace batteries; Replacing batteries
614-40095-00 32 • • a. b. c. d. • ••• • • • 6.3 When to replace batteries Eaton UPS batteries have an expected life span of 3-5 years. After 4 years of operation, the UPS will provide a battery replacement notification reminding you that your batteries are nearing the end of their useful life. You s...
Page 34 - Replacing the UPS equipped with a HotSwap MBP; Recycling the used equipment; Troubleshooting
614-40095-00 34 1. 2. 1. 2. 3. Warning: take care not to reverse the polarity + (red) and - (black) when connecting the batteries as this will destroy the device. 6.5 Replacing the UPS equipped with a HotSwap MBP The HotSwap MBP module makes it possible to service or even replace the UPS without aff...
Page 35 - Typical alarms and faults
614-40095-00 35 •• • 1.2.3. Events are silent status information that are recorded into the Event log. Example = "AC freq in range".Alarms are recorded into the Event log and displayed on the LCD status screen with the logo blinking. Some alarms may be announced by a beep every 3 seconds. Ex...
Page 37 - Silencing the alarm; Specification and technical characteristics
614-40095-00 37 •••••• Conditions Possible cause Action The Remote Power Off (RPO) switch is active or the RPO connector is missing. If the UPS Status menu displays the "Remote Power Off" notice, deactivate the RPO input. 7.2 Silencing the alarm Press the ESC (Escape) button on the front pan...
Page 38 - Extended Battery Module model list
614-40095-00 38 8.1 UPS model list Description Catalog Number Power rating Configuration Eaton 5PX 1000 RT2U G2Eaton 5PX 1000 RT2U Netpack G2 5PX1000RTG25PX1000RTNG2 1000W/1000VA Rack / Tower Eaton 5PX 1500 RT2U G2Eaton 5PX 1500 RT2U Netpack G2 5PX1500RTG25PX1500RTNG2 1440W/1440VA Rack / Tower Eaton...
Page 40 - Electrical output; Electrical output connection
614-40095-00 40 8.5 Electrical output All models Normal mode Battery mode Voltage regulation Boost : Vin*1.15 Buck : Vin*0.87 (-10% ,6%) Efficiency >96% 1000-2200 > 82%3000 > 85% Frequency regulation +/-0.1 Hz Nominal output 100/110/120/125V Frequency Follows input frequency 50/60Hz Output ...
Page 41 - Environmental and safety
614-40095-00 41 Catalog Number Output conection 5PX3000RT3UNG2 8.7 Battery Internal batteries Internal batteries EBM Specifications 1000VA: 48Vdc - 4 x 12V, 7Ah1500VA: 48Vdc - 4 x 12V, 9Ah2000VA: 72Vdc - 6 x 12V, 7Ah3000VA: 72Vdc - 6 x 12V, 9Ah 5PXEBM48RTG2: 48Vdc - 2 x 4 x 12V, 9Ah5PXEBM72RTG2: 72V...
Page 42 - Glossary
614-40095-00 42 Storage temperature -15 to 50°C (5 to 122 °F) Relative humidity 20 to 90 % (without condensation) Operating altitude Up to 3,000 meters (9,843 ft) above sea level, no derating for 40°c (104°F) room temperature Transit altitude Up to 10,000 meters (32,808 ft) above sea level Audible n...