Page 2 - CONTENTS
2 CONTENTS 1 PLEASE READ IMMEDIATELY 3 1.1 Important Information 1.2 Legal Provisions and Directives 1.3 Energy-Efficient Use of the Heat Pump 2 PURPOSE OF THE HEATPUMP 4 2.1 Application 2.2 Principle of Operation 3 BASELINE UNIT 4 4 ACCESSORIES 5 4.1 Brine Manifold 4.2 Brine Pressostat 5 TRANSPORT ...
Page 3 - READ IMMEDIATELY; Important Information; PLEASE READ IMMEDIATELY; Legal Provisions and Directives
3 READ IMMEDIATELY 1.1 Important Information The heat pump is not secured to the wooden pallet. The heat pump must not be tilted more than max. 45° (in either direction). Do not lift unit by the holes in the panel assemblies! In the case of large-capacity heating c i r c u i t s , t h e i n s t a l ...
Page 4 - Principle of Operation; BASELINE UNIT
4 3 2 PURPOSE OF HEAT PUMPBASELINE UNIT PURPOSE OF THE HEATPUMP 2.1 Application The brine-to-water heat pump is designed for use in existing or newly built heating systems. Brine is used as the heat carrier in the heat source system. Ground coils, ground collectors or similar systems can be used as ...
Page 5 - ACCESSORIES; TRANSPORT
5 5 4 ACCESSORIES 4.1 Brine Manifold The brine manifold ties the individual collector loops of the heat source system into a single main line which is connected to the heat pump. Integrated ball valves allow individual brine circuits to be shut off for venting purposes. ACCESSORIES TRANSPORT TRANSPO...
Page 6 - MOUNTING; INSTALLATION; General Information
6 MOUNTING 7.1 General The following connections need to be established on the heat pump: - supply/return flow of the brine system - supply/return flow of the space heating and water heating system - common return of space heating and water heating system - return, overflow valve - connection for ad...
Page 7 - Connection on Heat Source Side
7 CAUTION! MOUNTING pump installations where a power failure cannot readily be detected (e.g. holiday houses), the heating circuit must contain a suitable antifreeze product. The integrated expansion vessel has a capacity of 24 litres.This capacity is appropriate for buildings with a heated living s...
Page 8 - COMMISSIONING; Preparatory Steps; Cleaning of Heating Side
8 9 COMMISSIONINGCARE/CLEANING COMMISSIONING 8.1 General To e n s u r e p r o p e r c o m m i s s i o n i n g i t s h o u l d b e carried out by an after-sales service authorised by t h e m a n u f a c t u r e r. O n l y t h e n c a n a n e x t e n d e d warranty period of 3 years in total be grante...
Page 9 - Cleaning of Heat Source Side; DECOMMISSIONING; Shutdown in Summer; MALFUNCTIONS/TROUBLESHOOTING
9 10 CAUTION! 11 According to current knowledge, we recommendcleaning with a 5% phosphoric acid solution or, inthe case that cleaning needs to be performed morefrequently, with a 5% formic acid solution. In either case, the cleaning fluid should be at roomt e m p e r a t u r e . I t i s r e c o m m ...
Page 10 - EQUIPMENT DATA; APPENDIX
10 APPENDIX 12 12.1 DIMENSIONED DRAW-I N G 11 12.2 EQUIPMENT DATA 12 12.3 SCHEMATICS 12.3.1 Characteristics .. 7KS 13 12.3.2 Characteristics .. 9KS 14 12.3.3 Characteristics .. 11KS 15 12.3.4 Characteristics .. 14KS 16 12.4 WIRING DIAGRAMS 12.4.1 Control .. 7KS to .. 14KS 17 12.4.2 Load .. 7KS to .....
Page 11 - Dimensioned Drawing
11 APPENDIX: 12.1 DIMENSIONED DRAWING Dimensioned Drawing 12. 1 Maßbilder 12. 1 Maßbilder 12. 1 Maßbilder 12. 1 Maßbilder 12. 1 Maßbilder Heating circuit pressure gauge Brine circuit pressure gauge Heat source Heat pump inlet 1 1/4" external thread Heat source Heat pump outlet 1 1/4" externa...
Page 12 - Equipment Data
12 APPENDIX: 12.2 EQUIPMENT DATA Equipment Data EQUIPMENT DATA for Brine-to-Water Heat Pumps for Heating 1 TYPE AND COMMERCIAL DESCRIPTION ..7KS ..9KS ..11KS ..14KS 2 MODEL 2.1 Type compact compact compact compact 2.2 Enclosure type acc. to EN 60 529 IP 20 IP 20 IP 20 IP 20 2.3 Installation site ind...
Page 21 - Hydraulic Block Diagram
21 Hydraulic Block Diagram APPENDIX: 12.5 HYDRAULIC BLOCK DIAGRAM Check valve Shut-of f valve Overflow valve Safety assembly Circulating pump Expansion vessel Thermostat/manual valve Shut-of f valve with check valve Heat consumer T emperature sensor Flexible connecting hose Back-up heater Primary ci...
Page 22 - APPENDIX: 12.6 EC DECLARATION OF CONFORMITY; EC Declaration of Conformity; Declaration of Conformity
22 APPENDIX: 12.6 EC DECLARATION OF CONFORMITY EC Declaration of Conformity Declaration of Conformity The undersigned Glen Dimplex Deutschland GmbHDivision DimplexAm Goldenen Feld 18D-95326 Kulmbach hereby confirm that the design and construction of the product(s) listed below, in the version(s) pla...