Page 3 - WARNING; If wiring unit to operate with; (see Section C for factory setting wiring)
LISTINGS AND CODE APPROVALS The BF series fireplaces have been tested in accordance with the UL 2021 and CSA C22.2 No. 46 standards for fixed and location-dedicated electric room heaters. MODEL SPECIFICATIONS Model Number Description Voltage Volts Rated Power Watts Remote Control Wall Thermostat Ref...
Page 4 - SECTION A: FRAMING; Dimensions; use two conductor, non-metallic sheath cable with ground wire (3; RECOMMENDED WIRE AND FUSING REQUIREMENTS; Rough-in corner framing; Firebox dimensions
WARNING Ensure method of installation does NOT obscure the air intake slots on bottom front of unit in any manner. (see diagram in Section A) SECTION A: FRAMING Dimensions This fireplace is a zero clearance design. No combustibles can be placed on the top surface of the fireplace. Combustibles may b...
Page 5 - FIGURE 1; FIGURE 3
VOLTAGE SELECTOR SWITCH LOCATION IMPORTANT: Ensure that the incoming power supply voltage matches the setting of the voltage selector switch. NOTE: The voltage selector switch is located inside the exhaust panel on the top right hand corner. CAUTION: When changing the voltage selector switch from 24...
Page 6 - FACTORY SETTING WIRING; The unit is factory configured for 208/240 volt operation; 40 VOLT INSTALLATION; FIREPLA; POWER
SECTION C: FACTORY SETTING WIRING (WITHOUT MAIN POWER WALL SWITCH) IMPORTANT: The unit is factory configured for 208/240 volt operation NOTE: Use 3 conductor wire with ground (4 wires total) from the power supply (breaker panel) to the junction box on the unit. NOTE: All wiring must be completed pri...
Page 7 - 20 VOLT INSTALLATION; that all connections are tight.
SECTION C: FACTORY SETTING WIRING (WITHOUT MAIN POWER WALL SWITCH) IMPORTANT: The unit is factory configured for 208/240 volt operation NOTE: Use 2 conductor wire with ground (3 wires total) from the power supply (breaker panel) to the junction box on the unit. NOTE: All wiring must be completed pri...
Page 8 - 20 VOLT INSTALLATION (NO HEAT INSTALLATION)
SECTION C: FACTORY SETTING WIRING (WITHOUT MAIN POWER WALL SWITCH) (NO HEAT INSTALLATION) IMPORTANT: The unit is factory configured for 208/240 volt operation NOTE: Use 2 conductor wire with ground (3 wires total) from the power supply (breaker panel) to the junction box on the unit. NOTE: All wirin...
Page 9 - should not; 40 VOLT INSTALLATIONS
SECTION D: MAIN POWER WALL SWITCH WIRING OPTIONS MAIN POWER WALL SWITCH WIRING FOR 240 VOLT NOTE: This option should not be used with the remote control kit. NOTE: Before installing the unit you must have the following wires installed: 1. A 3 conductor wire with ground (4 wires total) from the power...
Page 10 - WALL
240 VOLT MAIN WALL SWITCH WIRING DIAGRAM 8 FIREPLA C E JU NCTI O N B O X 240 V POWER SUPPLY (BREAKER PANEL) WHITE - N RED – L2 BLACK – L1 WHITE – N BLACK – L1 GROUND - G WALL SWITCH RED – L2 GROUND - G
Page 11 - MAIN POWER WALL SWITCH WIRING; 20 VOLT INSTALLATIONS
MAIN POWER WALL SWITCH WIRING FOR 120 VOLT NOTE: This option should not be used with the remote control kit. NOTE: Before installing the unit have the following wires installed: 1. A 2 conductor wire with ground (3 wires total) from the power supply panel to the main switch wall box. 2. A 2 conducto...
Page 15 - Before installing the unit complete the following:
SECTION E: HEATER WALL SWITCH AND WALL THERMOSTAT WIRING OPTIONS HEATER WALL SWITCH WIRING FOR 120/240 VOLT NOTE: Before installing the unit complete the following: 1. Install main power connection with appropriate voltage as per Section C or Section D. 2. Install a 2 conductor wire with ground (3 w...
Page 16 - FIREPLACE JUNCTI
HEATER WALL SWITCH WIRING DIAGRAM FOR 120/240 VOLT (SEE SECTION C OR SECTION D FOR MAIN POWER CONNECTION) 14 FIREPLACE JUNCTI O N BOX RED – 2 WALL SWITCH RED – 1 GROUND - G
Page 17 - WALL MOUNTED THERMOSTAT WIRING
WALL MOUNTED THERMOSTAT WIRING FOR 120/240 VOLT NOTE: Before installing the unit complete the following: 1. Install main power connection with appropriate voltage as per Section C or Section D. 2. Install a 2 conductor wire with ground (3 wires total) from the thermostat wall box to the junction box...
Page 19 - FLAME OVERRIDE SWITCH WIRING; NOT AVAILABLE WITH NO HEAT INSTALLATION
FLAME OVERRIDE SWITCH WIRING FOR 120/240 VOLT NOT AVAILABLE WITH NO HEAT INSTALLATION NOTE: The fireplace can be wired to have a wall switch operate the heater independent of the flame . NOTE: Before installing the unit complete the following: 1. Install main power connection with appropriate voltag...
Page 23 - WIRING SCHEMATIC