Page 2 - Install Guide; M i c r o M o d u l e s u s e d w i t h t h e M I L - 4 7 1 1 H :; For instructions on configuring the micro modules, see the; D e s c r i p t i o n o f H a r d w a r e; MICROHUB
Install Guide Model: MIL-4711H 2 M i c r o M o d u l e s u s e d w i t h t h e M I L - 4 7 1 1 H : • MIL-4310M • MIL-4320M • MIL-4330M • MIL-4340M • MIL-4350M • MIL-4360M • MIL-4370M For instructions on configuring the micro modules, see the MIL-4300M Series Micro Module Installation Guide .. D e s ...
Page 3 - D e s c r i p t i o n o f t h e L E D s; link; The SYS and COL LEDs blink when the unit is operational.; D e s c r i p t i o n o f D i p S w i t c h e s
Install Guide Model: MIL-4711H 3 Figure 3.MIL-4711 (Rear View w/ the MIL-4310 Module) D e s c r i p t i o n o f t h e L E D s On the front panel of the MIL-4711H, there is one LED above each of the eight, 10BASE-T ports. If the port is in use, the LED will change to one of three colors to indicate t...
Page 4 - T h e D B - 9 S e r i a l P o r t; Figure 4.RS-232C Serial Port Pin Assignments; I n s t a l l a t i o n P r o c e d u r e; Follow these steps to connect the MIL-4711H to your network:; The voltage in use is visible.; The factory setting is 120VAC.; the network. Refer to the
Install Guide Model: MIL-4711H 4 T h e D B - 9 S e r i a l P o r t Figure 4.RS-232C Serial Port Pin Assignments Note: N/C=No Connect I n s t a l l a t i o n P r o c e d u r e Follow these steps to connect the MIL-4711H to your network: 1. Remove the MIL-4700H, power adapter, and cord from its shippi...
Page 5 - A s s i g n i n g a n I P A d d r e s s; alpha
Install Guide Model: MIL-4711H 5 A s s i g n i n g a n I P A d d r e s s Every device on a TCP/IP network is identified by two addresses: • The address is a 6-byte address assigned to the 4711H by the manufacturer. • The IP address is a 4-byte address assigned by the system admin. Set this. The MIL-...
Page 6 - Warning: Entering monitor will lock out
Install Guide Model: MIL-4711H 6 7. If prompted with a message like Warning: Entering monitor will lock out other Ethernet access and force reset , type [Y] to get the command prompt. 8. Type [N] to enter the network protocols menu. 9. Type [T] to enter the TCP/IP menu. 10. Change the settings for t...
Page 7 - S e t t i n g t h e I P A d d r e s s w i t h B O O T P; To s e t t h e I P A d d r e s s w i t h B O O T P o n a H P / U X s y s t e m :
Install Guide Model: MIL-4711H 7 6. Verify that the RARP daemon is running: ps-ax | grep RARP (for BSD UNIX) or ps-ef | grep RARP (for System V UNIX) Otherwise, start the RARP daemon by typing: /usr/etc/rarpd-a or /etc/rarpd-a If successful, the SYS LED flashes five times per second until the 4711H ...
Page 8 - Use the following menu sequence in sam:; Ethernet; and then click on; Apply
Install Guide Model: MIL-4711H 8 2. Use a text editor to open the /etc/hosts file and add the following line: 192.185.2.3 alpha 3. Use the following menu sequence in sam: Networking--> Communications--> Device Connectivity-->Boot Protocol--> Actions--> Add 4. In response to the progra...
Page 9 - L e g a l; R e g u l a t o r y A p p r o v a l s; C a n a d i a n E M I N o t i c e; Address: 1299 Orleans Drive; Five-Year Limited Warranty
Doc. Number: 75425 Rev. A L e g a l R e g u l a t o r y A p p r o v a l s • FCC Class A • UL 1950 • CSA 22 No. 950 • EN60950 • CE – EN55022 Class B– EN50082-1 C a n a d i a n E M I N o t i c e This Class A digital apparatus meets all the requirements of the Canadian Interference-Causing Equipment Re...