Page 2 - TABLE OF CONTENTS
2 ENG MGP-102D-3A SAFETY GUIDELINES .......................... Cover Page WARRANTY STATEMENT .................................. 3 WARNING CHART ............................................. 4-6 GLOSSARY ........................................................ 7 DUTY CYCLE ............................
Page 3 - LIMITED WARRANTY; ONE YEAR FROM DATE OF PURCHASE
3 ENG MGP-102D-3A LIMITED WARRANTY ❏ Retain original cash register sales receipt as proof of purchase for warranty work. ❏ Use reasonable care in the operation and maintenance of the product as described in the Owners Manual(s). ❏ Deliver or ship the product to the nearest DeVilbiss Air Power Manu...
Page 4 - RISK OF BURSTING; RISK OF EXPLOSION OR FIRE; HAZARD; IMPORTANT SAFETY INSTRUCTIONS
4 ENG MGP-102D-3A RISK OF BURSTING IT IS NORMAL FOR ELECTRICAL CONTACTS WITHIN THEMOTOR AND PRESSURE SWITCH TO SPARK. IF ELECTRICAL SPARKS FROM COMPRESSOR COME INTOCONTACT WITH FLAMMABLE VAPORS, THEY MAY IGNITE,CAUSING FIRE OR EXPLOSION. RESTRICTING ANY OF THE COMPRESSOR VENTILATIONOPENINGS WILL C...
Page 5 - RISK FROM FLYING OBJECTS; RISK TO BREATHING; RISK OF ELECTRICAL SHOCK
5 ENG MGP-102D-3A WHAT CAN HAPPEN HOW TO PREVENT IT RISK FROM FLYING OBJECTS THE COMPRESSED AIR STREAM CAN CAUSE SOFT TISSUEDAMAGE TO EXPOSED SKIN AND CAN PROPEL DIRT, CHIPS,LOOSE PARTICLES AND SMALL OBJECTS AT HIGH SPEED,RESULTING IN PROPERTY DAMAGE OR PERSONAL INJURY. ALWAYS WEAR ANSI Z87.1 APPR...
Page 6 - RISK FROM MOVING PARTS
6 ENG MGP-102D-3A MOVING PARTS SUCH AS THE PULLEY, FLYWHEEL AND BELTCAN CAUSE SERIOUS INJURY IF THEY COME INTO CONTACTWITH YOU OR YOUR CLOTHING. ATTEMPTING TO OPERATE COMPRESSOR WITH DAMAGEDOR MISSING PARTS OR ATTEMPTING TO REPAIR COM-PRESSOR WITH PROTECTIVE SHROUDS REMOVED CANEXPOSE YOU TO MOVING...
Page 7 - GLOSSARY; DESCRIPTION OF OPERATION
7 ENG MGP-102D-3A SCFM or CFM: Standard Cubic Feet per Minute; a unit of measurement of air delivery. PSIG or PSI: Pounds per square inch gauge. All DeVilbiss Air Power manufactured air compressors should be operated on not more than a 50% duty cycle. This means an air compressor that pumps more t...
Page 8 - Air Hose; Location of the Air Compressor; GROUNDING INSTRUCTIONS; INSTALLATION AND BREAK-IN PROCEDURES
8 ENG MGP-102D-3A Air Hose The air hose attached to your comporessor has an integral pressure adjusting valve at the working end of the hose. Should service or replacement be required, make sure that the pressure adjusting valve is present in the air hose line. It is normal for the adjustable pres...
Page 9 - OPERATING PROCEDURES; STORAGE
9 ENG MGP-102D-3A Compressed air from the outfit may contain water condensation. Do not spray unfiltered air at an item that could be damaged by moisture. Some air operated tools or devices may require filtered air. Read the instructions for the air tool or device. 1. Before plugging in the air co...
Page 10 - DESCRIPTION
10 ENG MGP-102D-3A PARTS LIST PARTS ABAILABLE FOR THIS UNIT DESCRIPTION PART NUMBER Safety Valve ............................................ TIA-4150Drain Valve .............................................. SS-2707Pressure Valve Assembly ........................ CAC-4324Outlet Tube ................
Page 11 - TROUBLESHOOTING GUIDE
11 ENG MGP-102D-3A High discharge pressure. Cannot be adjusted lower. Adjustable pressure valve not func- tioning. Air Leaks Hose fitting loose. Prolonged excessive use of air. Decrease the amount of air usage. Your compres- sor is not large enough for the air requirement. Tighten fitting. Compres...
Page 12 - wish to purchase; WARRANTY
12 ENG MGP-102D-3A OWNERS MANUAL FOR PERMANENTLY LUBRICATED AIR COMPRESSOR MODEL NO. 102D-3 (For Home Use Only) DeVilbiss Company Air Power • 213 Industrial Dr. • Jackson, TN 38301-9615 Call our Toll Free Number 1-800-888-2468, Ext 2, then 1, to obtain thelocation of the nearest Authorized Service...