Page 2 - TECHNICAL SPECIFICATIONS; PARAMETER
TECHNICAL SPECIFICATIONS (T A =25°C, airflow rate=300 LFM, V in =48Vdc, nominal Vout unless otherwise noted.) PARAMETER NOTES and CONDITIONS H48SV05020 (Standard) Min. Typ. Max. Units ABSOLUTE MAXIMUM RATINGS Input Voltage Continuous 80 Vdc Transient (100ms) 100ms 100 Vdc Operating Case Temperature ...
Page 3 - ELECTRICAL CHARACTERISTICS CURVES; Figure
ELECTRICAL CHARACTERISTICS CURVES 60 65 70 75 80 85 90 95 2.5 5 7.5 10 12.5 15 17.5 20 OUTPUT CURRENT(A) EFFICIENCY (%) 36Vin 48Vin 75Vin 0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0 9.0 10.0 11.0 12.0 13.0 14.0 2.5 5 7.5 10 12.5 15 17.5 20 OUTPUT CURRENT(A) P O WE R D IS S IP A T ION (W) 36Vin 48Vin 75Vin F...
Page 4 - For Negative Remote On/Off Logic
ELECTRICAL CHARACTERISTICS CURVES For Negative Remote On/Off Logic Figure 4: Turn-on transient at full rated load current (resistive load) (2 ms/div).Vin=48V. Top Trace: Vout; 2V/div; Bottom Trace: ON/OFF input: 5V/div Figure 5: Turn-on transient at zero load current (2 ms/div). Vin=48V. Top Trace: ...
Page 5 - battery impedance. Measure current as shown above.
ELECTRICAL CHARACTERISTICS CURVES Figure 8: Output voltage response to step-change in load current (50%-75%-50% of Imax; dI/dt = 0.1A/µs).Vin=48V. Load cap: 10µF, tantalum capacitor and 1µF ceramic capacitor. Top trace: Vout (100mV/div), Bottom trace: Iout (5A/div). Scope measurement should be made ...
Page 6 - Input Terminal Ripple Current, ic, at full rated output
ELECTRICAL CHARACTERISTICS CURVES Figure 11 : Input Terminal Ripple Current, ic, at full rated output current and nominal input voltage with 12 µ H source impedance and 33 µ F electrolytic capacitor (200 mA/div). Figure 12 : Input reflected ripple current, is, through a 12 µ H source inductor at nom...
Page 7 - Position the load between 51 mm and
ELECTRICAL CHARACTERISTICS CURVES 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 0 5 10 15 20 25 30 LOAD CURRENT (A) OUT P UT VOL T AGE (V) Vi n=48V Figure 14: Output voltage ripple at nominal input voltage (Vin=48V) and rated load current (Io=20A) (20 mV/div). Load capacitance: 1µF ceramic capacit...
Page 8 - THERMAL CURVES: NO HEATSINK
THERMAL CURVES: NO HEATSINK Figure 16: Case temperature measurement location. Pin locations are for reference only. Figure 17: Output current vs. ambient temperature and air velocity (V in <60V) Figure 18: Output current vs. ambient temperature and air velocity (V in =75V) Figure 19: Power dissip...
Page 9 - Soldering and Cleaning Considerations; DESIGN CONSIDERATIONS; Input Source Impedance
9 The input source must be insulated from the ac mains by reinforced or double insulation. The input terminals of the module are not operator accessible. If the metal baseplate is grounded , one Vi pin and one Vo pin shall also be grounded. A SELV reliability test is conducted on the system where th...
Page 10 - FEATURES DESCRIPTIONS; Over-Voltage Protection; Vout
FEATURES DESCRIPTIONS Over-Current Protection The modules include an internal output over-current protection circuit, which will endure current limiting for an unlimited duration during output overload. If the output current exceeds the OCP set point, the modules will automatically shut down (hiccup...
Page 12 - THERMAL CONSIDERATIONS; Thermal Testing Setup; Figure 24: Wind Tunnel Test Setup; Thermal Derating
THERMAL CONSIDERATIONS Thermal management is an important part of the system design. To ensure proper, reliable operation, sufficient cooling of the power module is needed over the entire temperature range of the module. Convection cooling is usually the dominant mode of heat transfer. Hence, the ch...
Page 13 - All pins are copper with Tin plating.
MECHANICAL DRAWING Pin No. Name Function 1 2 3 4 5 6 7 8 9 -Vin Case ON/OFF +Vin +Vout +SENSE TRIM -SENSE -Vout Negative input voltage Case Ground Remote ON/OFF Positive input voltage Positive output voltage Positive remote sense Output voltage trim Negative remote sense Negative output voltage Pin ...
Page 14 - PART NUMBERING SYSTEM; N R; MODEL LIST; MODEL NAME; CONTACT
PART NUMBERING SYSTEM H 48 S V 050 20 N R F A Form Factor Input Voltage Number of Outputs Product Series Output Voltage Output Current ON/OFF Logic Pin Length Option Code H - Half Brick 48V S- Single V- Value line 050- 5V 20- 20A N- Negative P- Positive R- 0.170” N- 0.145” K- 0.110” F- RoHS 6/6 (Lea...