Page 2 - TECHNICAL SPECIFICATIONS; PARAMETER
DS_S48SE05003_12292006 2 TECHNICAL SPECIFICATIONS T A = 25°C, airflow rate = 300 LFM, V in = 48 Vdc, nominal Vout unless otherwise noted. PARAMETER NOTES and CONDITIONS S48SE05003 (Standard) Min. Typ. Max. Units ABSOLUTE MAXIMUM RATINGS Input Voltage Continuous 80 Vdc Transient(100ms) 100ms 100 Vdc ...
Page 3 - ELECTRICAL CHARACTERISTICS CURVES
DS_S48SE05003_12292006 3 ELECTRICAL CHARACTERISTICS CURVES Figure 1: Efficiency vs. load current for minimum, nominal, and maximum input voltage at 25°C. Figure 2: Power dissipation vs. load current for minimum, nominal, and maximum input voltage at 25°C. Figure 3: Typical full load input characteri...
Page 4 - ) of 12 μH. Capacitor Cs offset possible
DS_S48SE05003_12292006 4 ELECTRICAL CHARACTERISTICS CURVES (CON.) Figure 7: (For positive remote on/off logic)Turn-on transient at zero load current (5 ms/div). Vin=48V. Top Trace: Vout, 2V/div; Bottom Trace: ON/OFF input, 2V/div. Figure 8: Output voltage response to step-change in load current (75%...
Page 5 - Figure 11: Input Terminal Ripple Current, i; Strip
DS_S48SE05003_12292006 5 ELECTRICAL CHARACTERISTICS CURVES Figure 11: Input Terminal Ripple Current, i c , at full rated output current and nominal input voltage with 12µH source impedance and 33µF electrolytic capacitor (200mA/div, 1us/div) Figure 12: Input reflected ripple current, i s , through a...
Page 6 - DESIGN CONSIDERATIONS; Input Source Impedance
DS_S48SE05003_12292006 6 DESIGN CONSIDERATIONS Input Source Impedance The impedance of the input source connecting to the DC/DC power modules will interact with the modules and affect the stability. A low ac-impedance input source is recommended. If the source inductance is more than a few µ H, we a...
Page 7 - Trim
DS_S48SE05003_12292006 7 FEATURES DESCRIPTIONS Over-Current Protection The modules include an internal output over-current protection circuit, which will endure current limiting for an unlimited duration during output overload. If the output current exceeds the OCP set point, the modules will automa...
Page 8 - ohm
DS_S48SE05003_12292006 8 R Load FEATURES DESCRIPTIONS (CON.) Output Voltage Adjustment To increase or decrease the output voltage set point, the modules may be connected with an external resistor between the TRIM pin and either the Vo(+) or Vo(-). The TRIM pin should be left open if this feature is ...
Page 9 - Thermal Derating; THERMAL CONSIDERATIONS; Thermal Testing Setup; Figure 19: Wind tunnel test setup
DS_S48SE05003_12292006 9 Thermal Derating Heat can be removed by increasing airflow over the module. To enhance system reliability, the power module should always be operated below the maximum operating temperature. If the temperature exceeds the maximum module temperature, reliability of the unit m...
Page 10 - PICK AND PLACE LOCATION SURFACE-MOUNT TAPE & REEL
DS_S48SE05003_12292006 10 PICK AND PLACE LOCATION SURFACE-MOUNT TAPE & REEL RECOMMENDED PAD LAYOUT (SMD)
Page 11 - Temp
DS_S48SE05003_12292006 11 LEADED (Sn/Pb) PROCESS RECOMMEND TEMP. PROFILE Time ( sec. ) Pre-heat temp. 140~180 ° C 60~120 sec. Peak temp. 210~230 ° C 5sec. Ramp-up temp. 0.5~3.0 ° C /sec. T emperatur e ( ° C ) 50 100 150 200 250 300 60 0 120 180 240 2nd Ramp-up temp. 1.0~3.0 ° C /sec. Over 200 ° C 40...
Page 12 - MECHANICAL DRAWING; Through-hole module; Name
DS_S48SE05003_12292006 12 MECHANICAL DRAWING Surface-mount module Through-hole module Pin No. Name Function 1 2 3 4 5 6 +Vin -Vin ON/OFF (Optional) -Vout TRIM (Optional) +Vout Positive input voltage Negative input voltage Remote ON/OFF (Optional) Negative output voltage Output voltage trim (Optional...
Page 13 - PART NUMBERING SYSTEM; MODEL LIST; MODEL NAME; CONTACT
DS_S48SE05003_12292006 13 PART NUMBERING SYSTEM S 48 S E 050 03 N R F A Product Type Input Voltage Number of Outputs Product Series Output Voltage Output Current ON/OFF Logic Pin Length/Type Option Code S - Small Power 48V- 36V~75V S - Single 1x1, 5A 050 – 5.0V 03 - 3A N - NegativeP - Positive E - N...