Page 2 - Powerful Solutions for Digital Plants; Scope
Powerful Solutions for Digital Plants MYNAH Technologies 504 Trade Center Blvd. Chesterfield, MO 63005 Telephone 636 681-1555 Fax 636 681-1660 www.mynah.com 1 1 INTRODUCTION 1.1 Scope This document is the User Manual for the Allen Bradley serial communication driver firmware for the Emerson DeltaV C...
Page 3 - Document; System
Powerful Solutions for Digital Plants MYNAH Technologies 504 Trade Center Blvd. Chesterfield, MO 63005 Telephone 636 681-1555 Fax 636 681-1660 www.mynah.com 2 1.2 Document Format This document is organized as follows: 1.3 System Specifications The following table lists the minimum hardware requireme...
Page 4 - Related
Powerful Solutions for Digital Plants MYNAH Technologies 504 Trade Center Blvd. Chesterfield, MO 63005 Telephone 636 681-1555 Fax 636 681-1660 www.mynah.com 3 1.4 Related Documents The following documents were referenced either directly or indirectly in the development of this document: n 96KH06.D01...
Page 5 - THEORY OF OPERATION
Powerful Solutions for Digital Plants MYNAH Technologies 504 Trade Center Blvd. Chesterfield, MO 63005 Telephone 636 681-1555 Fax 636 681-1660 www.mynah.com 4 2 THEORY OF OPERATION As part of the serial interface port license, a standard Modbus protocol is installed on the DeltaV PSIC prior to custo...
Page 7 - Downloading the firmware
Powerful Solutions for Digital Plants MYNAH Technologies 504 Trade Center Blvd. Chesterfield, MO 63005 Telephone 636 681-1555 Fax 636 681-1660 www.mynah.com 6 3 Downloading the firmware To begin installation of the Allen-Bradley driver, create a folder on the hard drive. The preferred location for t...
Page 8 - CONFIGURATION INFORMATION; Channel Attributes Block
Powerful Solutions for Digital Plants MYNAH Technologies 504 Trade Center Blvd. Chesterfield, MO 63005 Telephone 636 681-1555 Fax 636 681-1660 www.mynah.com 7 4 CONFIGURATION INFORMATION This section describes the steps necessary to configure the DeltaV PSIC and the Allen- Bradley PLC such that comm...
Page 9 - Attribute Defined
Powerful Solutions for Digital Plants MYNAH Technologies 504 Trade Center Blvd. Chesterfield, MO 63005 Telephone 636 681-1555 Fax 636 681-1660 www.mynah.com 8 Attribute Defined Values DeviceDataType 0 = Basic Protected 1 = Basic Protected Bit 2 = Basic Unprotected 3 = Basic Unprotected Bit 4 = PLC-5...
Page 15 - Dataset Configuration Display
Powerful Solutions for Digital Plants MYNAH Technologies 504 Trade Center Blvd. Chesterfield, MO 63005 Telephone 636 681-1555 Fax 636 681-1660 www.mynah.com 14 4.3 Dataset Configuration Display The following DeltaV screens are displayed during a typical PSIC configuration utilizing the above paramet...
Page 18 - Serial Port Configuration for DeltaV PSIC
Powerful Solutions for Digital Plants MYNAH Technologies 504 Trade Center Blvd. Chesterfield, MO 63005 Telephone 636 681-1555 Fax 636 681-1660 www.mynah.com 17 4.4 Serial Port Configuration for DeltaV PSIC In order for proper communication between the Programmable Serial Interface Card and the Allen...
Page 19 - Operational; Scope; Configuration
Powerful Solutions for Digital Plants MYNAH Technologies 504 Trade Center Blvd. Chesterfield, MO 63005 Telephone 636 681-1555 Fax 636 681-1660 www.mynah.com 18 · Stop Bits 1 or 2 5 Operational Check 5.1 Scope The following sections provide some assistance to ensure the interface is working properly....
Page 20 - Diagnostics
Powerful Solutions for Digital Plants MYNAH Technologies 504 Trade Center Blvd. Chesterfield, MO 63005 Telephone 636 681-1555 Fax 636 681-1660 www.mynah.com 19 · To assign a Dataset and a register in the Dataset to an I/O module, follow these steps: 1. Double click the IO_IN/IO_OUT parameter for the...
Page 21 - DeltaV – PLC/SLC Electrical Interface; Terminal Number Signal Description
Powerful Solutions for Digital Plants MYNAH Technologies 504 Trade Center Blvd. Chesterfield, MO 63005 Telephone 636 681-1555 Fax 636 681-1660 www.mynah.com 20 6 DeltaV – PLC/SLC Electrical Interface The electrical interface between DeltaV and the PLC-3, PLC-5 and SLC 5/XX conforms to the RS-232 pro...
Page 22 - RS-422/485 Pin Assignments for DeltaV PSIC
Powerful Solutions for Digital Plants MYNAH Technologies 504 Trade Center Blvd. Chesterfield, MO 63005 Telephone 636 681-1555 Fax 636 681-1660 www.mynah.com 21 6.2 RS-422/485 Pin Assignments for DeltaV PSIC Terminal Number Signal Description 1 Port 1 - Isolated Ground (GND) 2 Port 1 Half Duplex Data...
Page 23 - Wiring Connections for RS-232 Communications; Shield
Powerful Solutions for Digital Plants MYNAH Technologies 504 Trade Center Blvd. Chesterfield, MO 63005 Telephone 636 681-1555 Fax 636 681-1660 www.mynah.com 22 6.3 Wiring Connections for RS-232 Communications The figure below shows the connections between the 1785-KE module RS-232 port and the seria...