Page 2 - Absolute Maximum Ratings; Recommended Operating Conditions; Electrical Characteristics; Transmitter; Receiver
DELTA ELECTRONICS, INC. 2 Nov., 2006 Rev. 0C www.deltaww.com Absolute Maximum Ratings Parameter Symbol Min. Typ. Max. Unit Note Storage Temperature Ts -40 85 ºC Supply Voltage V CC 0 5 V Recommended Operating Conditions Parameter Symbol Min. Typ. Max. Unit Note Case Operating Temperature T C -5 +70 ...
Page 3 - Optical Characteristics; Parameter Symbol; Mask of the eye diagram for the optical transmit signal
DELTA ELECTRONICS, INC. 3 Nov., 2006 Rev. 0C www.deltaww.com Optical Characteristics (V CC =3.135V to 3.465V, Data Rate=155Mb/sec, PRBS=2 23 -1 NRZ, 9/125 μ m SMF) Parameter Symbol Min. Typ. Max. Unit Note Transmitter Output Optical Power (Avg.) P O -15 -8 dBm Optical Extinction Ratio E.R. 10 dB Cen...
Page 6 - Recommend Circuit Schematic; SerDes IC; * Depands on SerDes IC used
DELTA ELECTRONICS, INC. 6 Nov., 2006 Rev. 0C www.deltaww.com Recommend Circuit Schematic Laser Diode Photo Diode 1uH 1uH 0.1uF 10uF 0.1uF 0.01uF 0.01uF 0.01uF 0.01uF 0.1uF 10uF RES1 RES1 100 Ohms* RES1 RES1 RES1 10k Ohms 100 Ohms VCC Protocol Vcc SerDes IC Protocol IC PLD / PAL Mod_def 2 Mod_def 1 M...
Page 7 - Package Outline Drawing for Metal Housing with Bail de-latch
DELTA ELECTRONICS, INC. 7 Nov., 2006 Rev. 0C www.deltaww.com Package Outline Drawing for Metal Housing with Bail de-latch
Page 8 - SFP timing parameters for SFP management
DELTA ELECTRONICS, INC. 8 Nov., 2006 Rev. 0C www.deltaww.com SFP timing parameters for SFP management Parameter Symbol Min. Max. Unit Unit Conditions TX_DISABLE Assert time t_off 10 μ sec Time from rising edge of TX_DISABLE to when the optical output falls below 10% of nominal TX_DISABLE Negate time...
Page 9 - SFP timing parameters:; Successful recovery from transient safety fault condition
DELTA ELECTRONICS, INC. 9 Nov., 2006 Rev. 0C www.deltaww.com SFP timing parameters: Power on initialization of SFP transceiver, TX_DISABLE negated Power on initialization of SFP, TX_DISABLE asserted Initialization during hot plugging of SFP TRANSCEIVER. Example of initialization during hot plugging,...
Page 11 - Regulatory Compliance
DELTA ELECTRONICS, INC. 11 Nov., 2006 Rev. 0C www.deltaww.com Regulatory Compliance Feature Reference Performance Electromagnetic Interference (EMI) FCC Class B EN 55022 Class B (CISPR 22A) Radio Frequency Electromagnetic Field EN 61000-4-3 IEC 1000-4-3 Electrostatic Discharge to the Duplex LC Recep...
Page 12 - Ordering information for SFP modules; Blank; Related Products
DELTA ELECTRONICS, INC. 12 Nov., 2006 Rev. 0C www.deltaww.com Ordering information for SFP modules LCP-155B4JSRX 1 X 1 : Temperature Blank : -5 to +70 degree C H : -10 to +85 degree C T : -40 to +85 degree C Related Products z LCP-1250xxxx: 1.25Gb/s, Multimode and single mode transceiver from 500m t...