Page 3 - TABLE OF CONTENTS
• Split Sky Air • Outdoor Units 1 • Outdoor Units • R410A • RZQ-B TABLE OF CONTENTS RZQ-B 1 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 2 Specifications . . . . . . . . . . . . . . . . . . . . ...
Page 4 - Features
• Outdoor Units • R410A • RZQ-B • Split Sky Air • Outdoor Units 2 2 1 O u t d o o S p l i t R Z Q - B R 4 1 0 a 1 Features • Outdoor units for pair application • The Sky Air Inverter is developed for use in shops, restaurants and small offices. This innovative Daikin unit provides a more comfortable...
Page 5 - Specifications; -1 TECHNICAL SPECIFICATIONS
2 2 • Split Sky Air • Outdoor Units 3 • Outdoor Units • R410A • RZQ-B 2 Specifications 2-1 TECHNICAL SPECIFICATIONS RZQ71B8V3B RZQ100B8V3B RZQ100B7W1B RZQ125B8V3B Casing Colour Daikin white Material Painted galvanized steel plate Dimensions Packing Height mm 900 1475 1475 1475 Width mm 980 980 980 9...
Page 8 - -2 ELECTRICAL SPECIFICATIONS
• Outdoor Units • R410A • RZQ-B • Split Sky Air • Outdoor Units 6 2 2 Safety Devices High pressure switch High pressure switch Fan motor thermal protector Fan motor driver overload protector - Inverter overload protector - Overcurrent relay Fuse PC board fuse Standard Accessories Item Tie-wraps Inst...
Page 9 - Electrical data; SYMBOLS
2 3 • Split Sky Air • Outdoor Units 7 • Outdoor Units • R410A • RZQ-B 3 Electrical data 3D048637A RZQ71-125B7 Unit combination Power supply Comp. OFM IFM Indoor unit Outdoor unit Hz-volts Voltage range MCA TOCA MFA MSC RLA kW FLA kW FLA SYMBOLS MCA : Min. Circuit Amps (A) TOCA : Total Over Current A...
Page 12 - Options; Name of option
• Outdoor Units • R410A • RZQ-B • Split Sky Air • Outdoor Units 10 2 4 4 Options RZQ71 ∼ 140B7V3B Name of option Kit name RZQ71B7V3B RZQ100B8V3B RZQ125B8V3B RZQ100B7W1B RZQ125B7W1B RZQ140B7W1B Central drain plug KKPJ5F180 Refrigerant branch piping Twin KHRQ22M20TA7 Triple - KHRQ127H7 Double twin - -...
Page 13 - Capacity tables; Combination table; NOTES; NOTES
2 5 • Split Sky Air • Outdoor Units 11 • Outdoor Units • R410A • RZQ-B 5 Capacity tables 5 - 1 Combination table Possible indoor combination Simultaneous operation Outdoor models Twin Triple Double twin RZQ71B8V3B 35-35 (KHRQ22M20TA7) RZQ100B8V3BRZQ100B7W1B 50-50 (KHRQ22M20TA7) 35-35-35 (KHRQ127H7) ...
Page 14 - Cooling capacity tables; Cooling
• Outdoor Units • R410A • RZQ-B • Split Sky Air • Outdoor Units 12 2 5 5 Capacity tables 5 - 2 Cooling capacity tables RZQ71B8V3B Cooling Cooling capacity 230V [50Hz] Indoor Outdoor temp. (°CDB) EWB EDB 25 30 35 40 (°C) (°C) TC (kW) SHC (kW) CPI (-) TC (kW) SHC (kW) CPI (-) TC (kW) SHC (kW) CPI (-) ...
Page 21 - Model; Model
2 5 • Split Sky Air • Outdoor Units 19 • Outdoor Units • R410A • RZQ-B 5 Capacity tables 5 - 2 Cooling capacity tables RZQ250B7W1B (Pair / Twin / Double twin) Cooling Cooling capacity 400 V [50Hz] Indoor Outdoor temperature (°CDB) 25 30 35 40 °CWB TC (kW) SHC (kW) CPI (-) TC (kW) SHC (kW) CPI (-) TC...
Page 22 - Heating capacity tables; Heating
• Outdoor Units • R410A • RZQ-B • Split Sky Air • Outdoor Units 20 2 5 5 Capacity tables 5 - 3 Heating capacity tables RZQ71B8V3B (Pair + Twin) Heating Heating capacity 230V [50Hz] Indoor Outdoor temp. (°CWB) EDB − 15 − 10 − 5 0 6 10 (°C) TC (kW) CPI (-) TC (kW) CPI (-) TC (kW) CPI (-) TC (kW) CPI (...
Page 30 - Dimensional drawing & centre of gravity; Dimensional drawing
• Outdoor Units • R410A • RZQ-B • Split Sky Air • Outdoor Units 28 2 6 6 Dimensional drawing & centre of gravity 6 - 1 Dimensional drawing 3TW25144-1A unit (mm) 1 Gas pipe connection J 15.9 flare 2 Liquid pipe connection - J 9.5 flare 3 Service port (in the unit) 4 Grounding terminal M5 (in swit...
Page 32 - Dimensional drawings and accessories
• Outdoor Units • R410A • RZQ-B • Split Sky Air • Outdoor Units 30 2 6 6 Dimensional drawing & centre of gravity 6 - 2 Dimensional drawings and accessories 3D041017C RZQ200-250B7
Page 33 - Centre of gravity
2 6 • Split Sky Air • Outdoor Units 31 • Outdoor Units • R410A • RZQ-B 6 Dimensional drawing & centre of gravity 6 - 3 Centre of gravity 4TW26569-1 RZQ200-250B7 Center of foundation bolt hole(oblong hole) Center of foundation bolthole (oblong hole) Center of foundation bolt hole Center of founda...
Page 34 - Piping diagram
• Outdoor Units • R410A • RZQ-B • Split Sky Air • Outdoor Units 32 2 7 7 Piping diagram 3TW26735-1 RZQ71B (Pair) Indoor unit Field piping J 15.9 C1220T-0 Field piping J 9.5 C1220T-0 Low pressure sensor Heat exchanger Filter Stop valve (with service port 5/16’ flare) Filter Electronic expansion valve...
Page 39 - Wiring diagram
2 8 • Split Sky Air • Outdoor Units 37 • Outdoor Units • R410A • RZQ-B 8 Wiring diagram 2TW26736-1A RZQ71B8V3B A1P Printed circuit board A2P Printed circuit board (INV) BS1 Push button switch (forced defrost / pump down) C1-C2-C3 Capacitor DS1 Dip switch F1U Fuse (T6, 3A/250V) HAP (A1P) Light emitti...
Page 41 - Sound data; Sound pressure spectrum
2 9 • Split Sky Air • Outdoor Units 39 • Outdoor Units • R410A • RZQ-B 9 Sound data 9 - 1 Sound pressure spectrum 3TW26737-1 Sound pressure level [dB(A)] Octave band center frequency (Hz) RZQ71B8V3B - Cooling NOTES 1 Data is valid at free field condition 2 Data is valid at nominal conditions. 3 dB(A...
Page 44 - Sound power spectrum
• Outdoor Units • R410A • RZQ-B • Split Sky Air • Outdoor Units 42 2 9 9 Sound data 9 - 2 Sound power spectrum 3TW26737-3 Sound pressure level [dB(A)] Octave band center frequency (Hz) RZQ71B7V3B - Cooling NOTES 1 Data is valid at free field condition 2 Data is valid at nominal conditions. 3 dB(A) =...
Page 46 - Installation; 0 - 1 Refnet pipe systems
• Outdoor Units • R410A • RZQ-B • Split Sky Air • Outdoor Units 44 2 10 10 Installation 10 - 1 Refnet pipe systems Liquid side junction Discharge gas side junction Suction gas side junction Liquid side header Discharge gas side header Liquid side junction Closed pipes Reducers- Expanders 1TW25799-1E
Page 47 - lateral connection per row; A. Non stacked installation; Obstacles exist in front of the air inlet; B. Stacked installation
2 10 • Split Sky Air • Outdoor Units 45 • Outdoor Units • R410A • RZQ-B 10 Installation 10 - 2 Service space 3TW26739-4 Do not stack more than one unit.About 100mm is required as the dimension for laying the upper outdoor unit’s drain pipe.Get the portion A sealed so that air from the outlet does no...
Page 48 - Operation range; Model name
• Outdoor Units • R410A • RZQ-B • Split Sky Air • Outdoor Units 46 2 11 11 Operation range 3TW26733-1 RZQ71-100-125-140B Outdoor temp. (°CDB) Operation range Allowable range of operation (pull-down) Indoor temp. (°CWB) Cooling Heating Indoor temp. (°CDB) Outdoor temp. (°CWB) Operation range Allowabl...