Page 2 - Photocatalytic Air Purifier L-Series; Photocatalytic Air Purifier
SiBE811120 Photocatalytic Air Purifier L-Series 1 Photocatalytic Air Purifier L-Series MC70L 3VM 1. Precautions for Use.................................................................................2 1.1 Required Conditions .............................................................................
Page 3 - Precautions for Use; Required Conditions; Power Supply; This product is for home use. Never use for other purposes.
Precautions for Use SiBE811120 2 Photocatalytic Air Purifier L-Series 1. Precautions for Use 1.1 Required Conditions Power Supply 1 φ , 220 - 240 V, 50 Hz 1 φ , 220 - 230 V, 60 Hz Precautions z This product is for home use. Never use for other purposes. z This product is for indoor use only. Do not ...
Page 4 - Functions
SiBE811120 Functions Photocatalytic Air Purifier L-Series 3 2. Functions Category Functions M C 70L P V M B P asic Function Odor sensor { Dust sensor { 3-directional suction { Health & Comfort Flash streamer discharge { Number of streamer needle 6 Pre-filter { Electrostatic filter { Pleated filt...
Page 5 - Specifications
Specifications SiBE811120 4 Photocatalytic Air Purifier L-Series 3. Specifications 3.1 Specifications 50 Hz, 220 - 230 - 240 V / 60 Hz, 220 - 230 V Note: ★ 1. The colors are shown as below. ★ 2. Operating sound levels are the average of values measured at 1 m away from the front, left, right and top...
Page 6 - Dimensions; VM
SiBE811120 Specifications Photocatalytic Air Purifier L-Series 5 3.2 Dimensions MC70L P VM 11 8 90 52 576 395 230 4 11 4 Manufacturer's Label Plug type : C-TypeType of Cordage : H05VVH2-FCross Sectional Area : 0.75mm 2 No. of conductors : 2Length outside machine : 2000 ± 50 • Required installation s...
Page 7 - Wiring Diagram
Specifications SiBE811120 6 Photocatalytic Air Purifier L-Series 3.3 Wiring Diagram MC70L P VM A3P H7P H9P H3P H4P H6P H5P H8P H2P H11P H10P BS2 BS1 H17P H16P H21P H13P H19P H15P H14P H12P H18P H26P H25P H10 14 1 1 6 1 4 3 1 A4P S128 S1 S129 S35 6 1 Z2C CN1 6 14 N=3 A2P A1P GRN POWER SUPPLY WHT WHT ...
Page 8 - Packaging Drawing; Arrow view A
SiBE811120 Specifications Photocatalytic Air Purifier L-Series 7 3.4 Packaging Drawing MC70L P VM Pleated filter Main unit Product cover A Arrow view A Power code Wireless remote controller C: 2P286955 Accessory kit
Page 9 - Operation Manual; Recovery; Deodorising and decomposing odour in the air; • The decomposition cycle that maintains deodorising capability.; Adsorption; Features; About air purifying; • The purifying capacity improves as the airflow rate increases.
Operation Manual SiBE811120 8 Photocatalytic Air Purifier L-Series 4. Operation Manual 4.1 Features 1 Recovery Decomposition The odour adsorption capability is recovered. The streamer discharge decomposes odour. Replacement of the deodorising catalyst is unnecessary. The repeating of this cycle main...
Page 10 - What is the “Streamer” function?
SiBE811120 Operation Manual Photocatalytic Air Purifier L-Series 9 2 What is the “Streamer” function? This function uses a “streamer discharge”, a type of plasma discharge, to generate high-speed electrons with strong oxidation power inside the air purifier, reducing or removing odour swiftly. (The ...
Page 11 - Safety Precautions; WARNING; WARNING; Power supply
Operation Manual SiBE811120 10 Photocatalytic Air Purifier L-Series 4.2 Safety Precautions 3 Safety Precautions Before use, read these Safety Precautions to ensure proper handling of equipment. The precautions used in this manual are classified into the following two types. Both contain important sa...
Page 12 - Main unit; CAUTION
SiBE811120 Operation Manual Photocatalytic Air Purifier L-Series 11 4 WARNING Main unit CAUTION Power supply cord and plug Main unit • Do not use combustible substances, i.e., hair spray, insecticides, etc., near the unit.Do not wipe the unit with benzene or thinner. These substances may lead to cra...
Page 13 - Precautions during use
Operation Manual SiBE811120 12 Photocatalytic Air Purifier L-Series 5 Safety Precautions CAUTION Main unit Other This product does not remove the harmful substances (carbon monoxide, etc.) in cigarette smoke. Streamer discharge and electric dust collection • Odour may escape from the air outlet due ...
Page 14 - Name and Operation of Each Part; Front
SiBE811120 Operation Manual Photocatalytic Air Purifier L-Series 13 4.3 Name and Operation of Each Part 6 X X X X X X X X X X X Name and Operation of Each Part Front Rear Unit display Air inlet for air quality sensor (dust sensor) Receiver Air inlet for odour sensor Front panel Air inlet Air outlet ...
Page 15 - Remote controller
Operation Manual SiBE811120 14 Photocatalytic Air Purifier L-Series 7 X X X X Name and Operation of Each Part Remote controller Page 13, 14. Unit display Child proof lock lamp (orange) Auto fan lamp (yellow) Child proof lock button It prevents small children from mishandling the unit. ON / OFF butto...
Page 16 - change button
SiBE811120 Operation Manual Photocatalytic Air Purifier L-Series 15 8 X X X X Operation lamp Filter reset button Page 14. OFF TIMER lamp (yellow) Page 21. Filter lamp (orange) UNIT lamp (orange) Page 21. Page 19, 20. Odour sensor lamp Lights up Odour Strong Green Green Green • Turbo lamp (orange)• A...
Page 17 - Preparation before Operation; Accessories check; Remove the front panel.
Operation Manual SiBE811120 16 Photocatalytic Air Purifier L-Series 4.4 Preparation before Operation 9 AB C D Preparation before Operation Accessories check Confirm all the accessories are included. A: Pleated filter…1 sheet < For initial installation > Inside cushion B: Operation manual…1 boo...
Page 18 - Attach the front panel.
SiBE811120 Operation Manual Photocatalytic Air Purifier L-Series 17 10 4 Attach the pleated filter. Make sure to set the prefilter (green) and the pleated filter (front: white, rear: blue) in place. If you operate the unit without them, the unit may be damaged. 1) Fit the holes (5 each on the right ...
Page 19 - Installation of the unit; Installed on a table or the floor; Do not use the unit in the following places.
Operation Manual SiBE811120 18 Photocatalytic Air Purifier L-Series 11 Preparation before Operation Installation of the unit Installed on a table or the floor 100cm from ceiling 50cm from wall Airflow 50cm from wall 10cm from wall Hints for smart installation • To remove house dust, it is effective ...
Page 20 - Preparation of remote controller; A battery is already set in the remote controller.; Battery replacement; How to use
SiBE811120 Operation Manual Photocatalytic Air Purifier L-Series 19 12 Preparation of remote controller A battery is already set in the remote controller. • The remote controller can be used only after pulling out the clear sheet. Clear sheet Battery replacement 1 234 Move the tab of the cover on th...
Page 21 - How to Operate; To start the operation; To operate the unit according to the cleanness level of the air; To clean the air in the room quickly; To set the timer
Operation Manual SiBE811120 20 Photocatalytic Air Purifier L-Series 4.5 How to Operate 13 How to Operate • Operation starts and the airflow rate lamp lights up. • When you press next time, operation starts with the same settings as the previous operation. • You can release the childproof lock by pre...
Page 23 - Quick Reference Table of Maintenance
Operation Manual SiBE811120 22 Photocatalytic Air Purifier L-Series 4.6 Quick Reference Table of Maintenance 15 Quick Reference Table of Maintenance WARNING 1 Front panel 2 Prefilter 3 4 Wipe Vacuum cleaner Rinse with water Soak, drain and dry Wipe Soak, drain and dry Wipe Care and Cleaning Page 19,...
Page 25 - Removing and Attaching Each Part; Remove
Operation Manual SiBE811120 24 Photocatalytic Air Purifier L-Series 4.7 Removing and Attaching Each Part 17 1 Push Clip 2 Note 3 Handles UNIT1 1)Pull 2)Up 4 Handles 1)Pull 2)Up 1 Handles 1) 2 Handles UNIT1 1) 3 Other tabs (3 locations) UNIT1 4 Removing and Attaching Each Part Remove the front panel....
Page 26 - Removing and attaching the opposing pole plates; Remove the front panel and UNIT1.; Attach UNIT1 and the front panel.; Attach the opposing pole plates.; Attach
SiBE811120 Operation Manual Photocatalytic Air Purifier L-Series 25 18 UNIT1 Opposing pole plates Ionised wire 1 2 Ionised wire Knob Knob(white) 1 Knob(white) 2 Be careful not to cut the internal ionised wires. Opposing pole plates Removing and attaching the opposing pole plates CAUTION Wear rubber ...
Page 27 - Cleaning of UNIT1 and UNIT2
Operation Manual SiBE811120 26 Photocatalytic Air Purifier L-Series 4.8 Cleaning of UNIT1 and UNIT2 UNIT1 (Plasma ioniser) UNIT2 (Streamer unit) 19 Cleaning of UNIT1 and UNIT2 Soak, drain and dry Wipe X Page 17. Procedure UNIT1 Remove the parts. X Page 17, 18. X Page 18. Wipe Rub Rinse in running wa...
Page 29 - Replacement of the Pleated Filter; Disposal requirements
Operation Manual SiBE811120 28 Photocatalytic Air Purifier L-Series 4.9 Replacement of the Pleated Filter 21 X Page 17. X Page 17. Replacement of the Pleated Filter Replace Pleated filter Front panel UNIT1 Deodorising catalyst unit 1 Remove the front panel and UNIT1. 3 Attach UNIT1 and the front pan...
Page 30 - Sensitivity Setting of the Air Quality Sensor (Dust Sensor); The sensitivity of the air quality sensor can be changed.; With pressed, point the remote controller at the unit and
SiBE811120 Operation Manual Photocatalytic Air Purifier L-Series 29 4.10 Sensitivity Setting of the Air Quality Sensor (Dust Sensor) ON / OFF / Mode change button Airflow rate lamp 22 The sensitivity of the air quality sensor can be changed. Press on the unit for 10 seconds. 1 2 Change the sensitivi...
Page 31 - Childproof Lock Function: Special Mode; Outline; Special mode
Childproof Lock Function: Special Mode SiBE811120 30 Photocatalytic Air Purifier L-Series 5. Childproof Lock Function: Special Mode Outline In normal mode, once you disconnect the power plug, the childproof lock function is cancelled.The special mode enables the childproof lock function to resume ev...
Page 32 - Optional Accessories
SiBE811120 Optional Accessories Photocatalytic Air Purifier L-Series 31 6. Optional Accessories 6.1 Pleated Filter (Titanium Apatite Photocatalytic Filter) - KAC017A4E Notes: 1. Replacement guideline: Every 2 years (for about 10 years in total) 2. Appearance color: White (front), blue (back) 11 14 6...
Page 33 - Troubleshooting; Frequently Asked Question; Frequently Asked Questions; Before consulting your dealer, check the following points.; Answer; “If these lamps light or blink”; The air quality sensor lamp; Answer
Troubleshooting SiBE811120 32 Photocatalytic Air Purifier L-Series 7. Troubleshooting 7.1 Frequently Asked Question Frequently Asked Questions Before consulting your dealer, check the following points. Question : Can the deodorising catalyst unit be washed with water? Does the unit need to be replac...
Page 34 - Check before Requesting Servicing; The unit does not operate.; or is something obstructing the airflow?
SiBE811120 Troubleshooting Photocatalytic Air Purifier L-Series 33 7.2 Check before Requesting Servicing Troubleshooting Before consulting your dealer or asking for repairs, check the following points. If the problems still can not be solved, consult your dealer. The unit does not operate even if th...
Page 35 - The unit does not blow air.
Troubleshooting SiBE811120 34 Photocatalytic Air Purifier L-Series Troubleshooting Before consulting your dealer or asking for repairs, check the following points. If the problems still can not be solved, consult your dealer. A crackling or buzzing sound is heard during operation. A fizzing sound is...
Page 36 - Diagnosis; Caution
SiBE811120 Troubleshooting Photocatalytic Air Purifier L-Series 35 7.3 Diagnosis Be sure to turn off the power switch before connecting or disconnecting connectors, or parts may be damaged. Caution Problem Supposed Causes Diagnosis The air purifier does not operate or none of the indication lamps li...
Page 37 - Wiring Check after Replacing PCBs; Check the following points after replacing the PCBs.; Wiring check mode using the remote controller; If there is any wrong connection, correct it.
Wiring Check after Replacing PCBs SiBE811120 36 Photocatalytic Air Purifier L-Series 8. Wiring Check after Replacing PCBs Check the following points after replacing the PCBs. Wiring check mode using the remote controller (1) Insert the power plug.(2) Press the [OFF TIMER] button within 2 seconds. ...
Page 38 - Removal Procedure; Removal of Front Panel / Filters; Step
SiBE811120 Removal Procedure Photocatalytic Air Purifier L-Series 37 9. Removal Procedure 9.1 Removal of Front Panel / Filters Procedure Warning Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work. Step Procedure Points 1. Appearance 2. Remove the fr...
Page 40 - Remove the plasma
SiBE811120 Removal Procedure Photocatalytic Air Purifier L-Series 39 3. Remove the pre-filter. When reassembling, fit the pre-filter as the “FRONT” mark comes front. 1 Pull the recessed part of the pre-filter upper section and unfasten the right and left hooks (4 in total). 2 Remove the pre-filter...
Page 44 - Remove the deodorizing
SiBE811120 Removal Procedure Photocatalytic Air Purifier L-Series 43 6. Remove the deodorizing catalytic filter. 1 Unfasten the 4 hooks of the deodorizing catalyst unit. 2 Raise the deodorizing catalytic filter from the base and remove it. When reassembling, fit the lower hooks first, and then ben...
Page 46 - Removal of Streamer Unit
SiBE811120 Removal Procedure Photocatalytic Air Purifier L-Series 45 9.2 Removal of Streamer Unit Procedure Warning Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work. Step Procedure Points 1 Pull out the streamer unit. Caution Do not disassemble th...
Page 47 - Removal of Ionized Wire
Removal Procedure SiBE811120 46 Photocatalytic Air Purifier L-Series 9.3 Removal of Ionized Wire Procedure Warning Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work. Step Procedure Points 1 Unfasten the 2 hooks and lift the opposing pole plate to d...
Page 48 - Removal of Control / Display PCB
SiBE811120 Removal Procedure Photocatalytic Air Purifier L-Series 47 9.4 Removal of Control / Display PCB Procedure Warning Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work. Step Procedure Points 1 Remove the 3 screws of the display cover ASSY. 2 ...
Page 49 - Unfasten the 4 hooks.
Removal Procedure SiBE811120 48 Photocatalytic Air Purifier L-Series 4 Unfasten the 4 hooks. 5 Disconnect the connector for the dust sensor [S1] and remove the control / display PCB. 6 The figure shows the control / display PCB. [S1]: dust sensor[S128]: power supply PCB[SW1]: main switch[SW2]: filte...
Page 50 - Removal of Fan Motor; Preparation; Untie the power cord.
SiBE811120 Removal Procedure Photocatalytic Air Purifier L-Series 49 9.5 Removal of Fan Motor Procedure Warning Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work. Step Procedure Points 1. Remove the back cover. Preparation 1 Remove the 2 screws fro...
Page 52 - mark on the fan with
SiBE811120 Removal Procedure Photocatalytic Air Purifier L-Series 51 2 The figure shows the wiring of the wire harness. 3 Disconnect the connector for the fan motor [S2]. 4 Unscrew the nut and pull out the fan. When reassembling, align the mark on the fan with the D cut on the motor shaft. Nut s...
Page 54 - Removal of Power Supply PCB / High Voltage PCB
SiBE811120 Removal Procedure Photocatalytic Air Purifier L-Series 53 9.6 Removal of Power Supply PCB / High Voltage PCB Procedure Warning Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work. Step Procedure Points 1 Disconnect the connector for the po...
Page 55 - voltage PCB
Removal Procedure SiBE811120 54 Photocatalytic Air Purifier L-Series 4 Disconnect the 2 GND connectors (green). 5 Remove the 2 screws. 6 Lift up the upper part of the power supply PCB and unfasten the hook. Then remove the power supply PCB. [S2]: fan motor[S8]: power supply[S11]: joint connector for...
Page 56 - White : streamer unit
SiBE811120 Removal Procedure Photocatalytic Air Purifier L-Series 55 7 Remove the screw. 8 Unfasten the hook and remove the high voltage PCB. 9 Disconnect the 2 connectors.Red : plasma ionizer White : streamer unit Step Procedure Points (R12380) (R12381) Hook Red White Hook (R14731) Press the hook.
Page 57 - Removal of Power Cord
Removal Procedure SiBE811120 56 Photocatalytic Air Purifier L-Series 9.7 Removal of Power Cord Procedure Warning Be sure to wait for 10 minutes or more after turning off all power supplies before disassembling work. Step Procedure Points 1 Remove the 2 screws from the front side. 2 Pull the base ASS...
Page 59 - Warning
Head Office:Umeda Center Bldg., 2-4-12, Nakazaki-Nishi,Kita-ku, Osaka, 530-8323 Japan Tokyo Office:JR Shinagawa East Bldg., 2-18-1, Konan,Minato-ku, Tokyo, 108-0075 Japan http://www.daikin.com/global_ac/ All rights reserved c Warning Daikin products are manufactured for export to numerous countries ...