Page 3 - re; technical data
ZEAS refrigeration condensing units ÈEEDEN09-7415ËÍ Daikin Europe N.V. is approved by LRQA for its QualityManagement System in accordance with the ISO9001standard. ISO9001 pertains to quality assurance regardingdesign, development, manufacturing as well as to servicesrelated to the product. Daikin u...
Page 5 - ZEAS refrigeration condensing units; I Outdoor units
• Outdoor units • ZEAS refrigeration condensing units 1 • ZEAS refrigeration condensing units • Table of Contents ZEAS refrigeration condensing units I Outdoor units 1 LRMEQ-AY1 ....................................... 3 2 LRLEQ-AY1 ..................................... 31 3 1 2
Page 7 - TABLE OF CONTENTS
• Refrigeration • ZEAS refrigeration condensing units 3 • ZEAS refrigeration condensing units • Outdoor units • LRMEQ-AY1 TABLE OF CONTENTS LRMEQ-AY1 1 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 2 Specification...
Page 8 - Features
• ZEAS refrigeration condensing units • Outdoor units • LRMEQ-AY1 • Refrigeration • ZEAS refrigeration condensing units 4 1 Features 1 1 ZE AS r ef ri g Re fr ig er at io LR ME Q- AY 1 Ou td oo r un i • Medium temperature applications: 12.2~37.0 kW • DC inverter controlled scroll compressors open th...
Page 9 - Specifications; -1 Electrical Specifications
• Refrigeration • ZEAS refrigeration condensing units 5 • ZEAS refrigeration condensing units • Outdoor units • LRMEQ-AY1 2 Specifications 1 2 2-1 Electrical Specifications LRMEQ5AY1 LRMEQ6AY1 LRMEQ8AY1 LRMEQ10AY1 LRMEQ12AY1 LRMEQ15AY1 LRMEQ20AY1 Power supply Phase 3 Frequency Hz 50 Voltage V 380-41...
Page 10 - -3 Electrical Specifications
• ZEAS refrigeration condensing units • Outdoor units • LRMEQ-AY1 • Refrigeration • ZEAS refrigeration condensing units 6 2 Specifications 1 2 2-3 Electrical Specifications LRMEQ5AY1 LRMEQ6AY1 LRMEQ8AY1 LRMEQ10AY1 LRMEQ12AY1 LRMEQ15AY1 LRMEQ20AY1 Current - 50Hz Maximum starting current (MSC) - - 74 ...
Page 11 - Nomenclature; Outdoor unit
• Refrigeration • ZEAS refrigeration condensing units 7 • ZEAS refrigeration condensing units • Outdoor units • LRMEQ-AY1 3 Nomenclature 1 3 Nomenclature Outdoor unit LR M E Q 5 A Y1 Power supply symbol Y1: 3 φ 380-415V, 50Hz Indicates major design category Capacity indication 5: 5HP Refrigerant Q: ...
Page 12 - Electrical data
• ZEAS refrigeration condensing units • Outdoor units • LRMEQ-AY1 • Refrigeration • ZEAS refrigeration condensing units 8 4 Electrical data 1 4 3D064891 NO TES RLA is based on the following conditions, Outdoor temperature, 32°C DB Suction SH, 10°C Saturated temperature equivalent to suction pressure...
Page 13 - Options
• Refrigeration • ZEAS refrigeration condensing units 9 • ZEAS refrigeration condensing units • Outdoor units • LRMEQ-AY1 5 Options 1 5 LRMEQ5,6,8,10,12,15,20AY1(E)LRLEQ5,6,8,10,12,15,20AY1(E) 3D065082 NOTE Ƈ : Order products 1. Series Condensing unit for refrigeration system Model Option name LRLEQ...
Page 14 - Capacity tables; - 1 Cooling capacity tables
• ZEAS refrigeration condensing units • Outdoor units • LRMEQ-AY1 • Refrigeration • ZEAS refrigeration condensing units 10 6 Capacity tables 6 - 1 Cooling capacity tables 1 6 LRMEQ5-6AY1 3D065031 NOTES is specifi ed point. The condition of characteristics of the table: 10°C (suction SH)Consider decre...
Page 16 - Dimensional drawing & centre of gravity; - 1 Dimensional drawing
• ZEAS refrigeration condensing units • Outdoor units • LRMEQ-AY1 • Refrigeration • ZEAS refrigeration condensing units 12 7 Dimensional drawing & centre of gravity 7 - 1 Dimensional drawing 1 7 3D064898 N° Parts Name Remarks 1 Liquid pipe connection port ø9,5 2 Gas pipe connection port ø19.1 3 ...
Page 20 - - 2 Centre of gravity
• ZEAS refrigeration condensing units • Outdoor units • LRMEQ-AY1 • Refrigeration • ZEAS refrigeration condensing units 16 7 Dimensional drawing & centre of gravity 7 - 2 Centre of gravity 1 7 LRMEQ5,6AY1(E)LRLEQ5,6AY1(E) 4D065026 Center of foundationbolt hole Center of foundation bolt hole Cent...
Page 22 - Piping diagram
• ZEAS refrigeration condensing units • Outdoor units • LRMEQ-AY1 • Refrigeration • ZEAS refrigeration condensing units 18 8 Piping diagram 1 8 LRLEQ5A, 6AY1(E)LRMEQ5A, 6AY1(E) FILTER CHECK VALVE DOUBLE PIPE HEAT EXCHANGER SERVICE PORT CHECK VALVE ELECTRONIC EXPANSION VALVE SIGHT GLASS ELECTRONIC EX...
Page 25 - Wiring diagram
• Refrigeration • ZEAS refrigeration condensing units 21 • ZEAS refrigeration condensing units • Outdoor units • LRMEQ-AY1 9 Wiring diagram 9 - 1 Wiring diagram 1 9 LRLEQ5AY1(E), LRLEQ6AY1(E) LRMEQ5AY1(E), LRMEQ6AY1(E) 3D059917-1C NOTES 1 This wiring diagram is applied only to the outdoor unit. 2 At...
Page 28 - - 2 External connection diagram
• ZEAS refrigeration condensing units • Outdoor units • LRMEQ-AY1 • Refrigeration • ZEAS refrigeration condensing units 24 9 Wiring diagram 9 - 2 External connection diagram 1 9 LRMEQ5,6,8,10,12,15,20AY1(E)LRLEQ5, 6, 8, 10, 12, 15, 20AY1(E) 3D065037 NOTES All wiring, components and materials to be p...
Page 29 - Sound data; 0 - 1 Sound pressure spectrum
• Refrigeration • ZEAS refrigeration condensing units 25 • ZEAS refrigeration condensing units • Outdoor units • LRMEQ-AY1 10 Sound data 10 - 1 Sound pressure spectrum 1 10 LRMEQ5AY1(E)LRLEQ5AY1 (E) 4D065019 NOTES 1 Over All (dB): (B,G,N is already rectifi ed) 2 Operating conditions: Power source: Y1...
Page 31 - Installation; 1 - 1 Installation method
• Refrigeration • ZEAS refrigeration condensing units 27 • ZEAS refrigeration condensing units • Outdoor units • LRMEQ-AY1 11 Installation 11 - 1 Installation method 1 11 LRMEQ5,6,8,10,12,15,20AY1(E)LRLEQ5,6,8,10,12,15,20AY1(E) 3D065029 NOTES Heights of walls in case of Patterns 1 and 2. Front: 1500...
Page 32 - 1 - 2 Fixation and foundation of units
• ZEAS refrigeration condensing units • Outdoor units • LRMEQ-AY1 • Refrigeration • ZEAS refrigeration condensing units 28 11 Installation 11 - 2 Fixation and foundation of units 1 11 LRMEQ5,6,8,10,12,15,20AY1(E)LRLEQ5,6,8,10,12,15,20AY1(E) 3D065348 NOTES The proportions of cement: sand: gravel for ...
Page 33 - Operation range
• Refrigeration • ZEAS refrigeration condensing units 29 • ZEAS refrigeration condensing units • Outdoor units • LRMEQ-AY1 12 Operation range 1 12 LRMEQ5,6,8,10,12,15,20AY1 4D064918 NOTES See operation limits and performance characteristics.When the outside temp. is low, it lowers more than set temp...