• I ndoor U nits • 4-WAY BLOW CEI LIN G SU SPEND ED CASSET TE • F XUQ-M AV1 1 1 • VR V Sy st ems • Indoor Unit s 1 1 Specifications I n d o o r U n i t V R V S y s t e m s F X U Q - M A V 1 4 - W a y B l o w 1 -1 TE CHNICAL SP ECI FICATIONS FXUQ 71MAV1 F XUQ100 MA V1 F XU Q125 MAV1 P ower input (Nom...
Page 4 - Safety device settings
• I ndoor U nits • 4-WAY BLOW CEI LIN G SU SPEND ED CASSET TE • F XUQ-M AV1 1 2 • VR V Sy st ems • Indoor Unit s 3 2 Safety device settings 4D013856E FXUQ71MA FXUQ100MA FXUQ125MA FAN MOTOR THERMAL PROTECTOR ° C OFF: 130 ± 5
Page 5 - Options
3 1 3 • VRV Sys tem s • I ndoor U nits 4 • Indoor Unit s • 4-W AY BLOW C EILI NG SUSPEN DED C ASSETT E • FXU Q-MAV1 3 Options 3D045452A FXUQ71MA FXUQ100MA FXUQ125MA SEALING MEMBER OF AIR DISCHARGE OUTLET KDBHJ49F80 KDBHJ49F140 DECORATION PANEL FOR AIR DISCHARGE KDBTJ49F80 KDBTJ49F140 VERTICAL FLAP K...
Page 6 - Control systems; Individual control systems
• I ndoor U nits • 4-WAY BLOW CEI LIN G SU SPEND ED CASSET TE • F XUQ-M AV1 1 4 • VR V Sy st ems • Indoor Unit s 5 4 Control systems Individual control systems Centralised control systems Others 3D045452A NOTES 1 ! Installation box for adapter PCB (KRP1B97) is necessary. FXUQ71MA FXUQ100MA FXUQ125MA...
Page 7 - Capacity tables; Cooling capacity tables
3 1 5 • VRV Sys tem s • I ndoor U nits 6 • Indoor Unit s • 4-W AY BLOW C EILI NG SUSPEN DED C ASSETT E • FXU Q-MAV1 5 Capacity tables 5 - 1 Cooling capacity tables FXUQ-MA ED39335P11 TC: Total capacity;kW – SHC: Sensible capacity;kW Unit size Nominal capacity Outdoor air temp. Indoor air temperature...
Page 8 - Heating capacity tables
• I ndoor U nits • 4-WAY BLOW CEI LIN G SU SPEND ED CASSET TE • F XUQ-M AV1 1 5 • VR V Sy st ems • Indoor Unit s 7 5 Capacity tables 5 - 2 Heating capacity tables FXUQ-MA ED39335P12 Unit Size Nominal capacity Outdoor air temperature Indoor air temperature ° CDB 16.0 18.0 20.0 21.0 22.0 24.0 ° CDB ° ...
Page 9 - Dimensional drawing & centre of gravity; Dimensional drawing
3 1 6 • VRV Sys tem s • I ndoor U nits 8 • Indoor Unit s • 4-W AY BLOW C EILI NG SUSPEN DED C ASSETT E • FXU Q-MAV1 6 Dimensional drawing & centre of gravity 6 - 1 Dimensional drawing FXUQ71MA 3D013860D 790 Suspension position Drain connection location for upper piping Brand name plate (Note 2) ...
Page 10 - Piping diagram
• I ndoor U nits • 4-WAY BLOW CEI LIN G SU SPEND ED CASSET TE • F XUQ-M AV1 1 7 • VR V Sy st ems • Indoor Unit s 9 7 Piping diagram FXUQ-MA 4D037995F Piping connection diameters Models A B FXUQ70,100,125MA ø9.5 ø15.9 Indoor heat exchanger Indoor unit Field piping ø A C1220T -0 Field piping ø B C1220...
Page 11 - Wiring diagram
3 1 8 • VRV Sys tem s • I ndoor U nits 10 • Indoor Unit s • 4-W AY BLOW C EILI NG SUSPEN DED C ASSETT E • FXU Q-MAV1 8 Wiring diagram 8 - 1 Wiring diagram FXUQ-MA 3D044973A Note 1BEV unit Power Supply 50~ 220-240V Indoor unit (Note 3) Receiver/display unit Wired remote control Control box Note 5 NOT...
Page 12 - Sound data; Sound pressure spectrum
• I ndoor U nits • 4-WAY BLOW CEI LIN G SU SPEND ED CASSET TE • F XUQ-M AV1 1 9 • VR V Sy st ems • Indoor Unit s 11 9 Sound data 9 - 1 Sound pressure spectrum NOTES 1 Over all (dB): 2 Power level (dB): 3 Measuring place: Anechoic chamber 4 Operating conditons:• Power source: 230V 50Hz • Cooling: Ret...
Page 13 - Air flow pattern
3 1 10 • VRV Sys tem s • I ndoor U nits 12 • Indoor Unit s • 4-W AY BLOW C EILI NG SUSPEN DED C ASSETT E • FXU Q-MAV1 10 Air flow pattern FXUQ71MA Cooling - air velocity distribution 4-way discharge, air flow direction: horizontal Cooling - air temperature distribution 4-way discharge, air flow dire...
Page 17 - TABLE OF CONTENTS; Spec ifi cati ons; Technical Speci fi cations; Di mens io nal d rawi ng & cen tre of gravi ty; Pipi ng di agram
• VRV Sys tem s • I ndoor U nits 1 • Indoor Unit s • 4-W AY BLOW C EILI NG SUSPEN DED C ASSETT E • BEVQ-MAVE TABLE OF CONTENTS BEVQ-MAVE 1 Spec ifi cati ons . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Technical Speci fi cations . . ...
Page 20 - Centre of gravi ty
• I ndoor U nits • 4-WAY BLOW CEI LIN G SU SPEND ED CASSET TE • BEVQ-M AVE 1 2 • VR V Sy st ems • Indoor Unit s 3 2 Dimensional drawing & centre of gravity 2 - 2 Centre of gravi ty BEVQ-MA 3D030851D
Page 22 - Wir ing diagram
• I ndoor U nits • 4-WAY BLOW CEI LIN G SU SPEND ED CASSET TE • BEVQ-M AVE 1 4 • VR V Sy st ems • Indoor Unit s 5 4 Wir ing diagram 4 - 1 Wiring diagram BEVQ-MA 3D044901B Control box To outdoor unit Note 4To interface adaptor for sky air series of indoor unit. To indoor unit Power Supply 50~ 220-240...