Page 3 - TABLE OF CONTENTS; Nominal capacity, capacity steps and nominal input; Technical specifications
TABLE OF CONTENTS FHYP-B 1 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 2 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....
Page 4 - Features
1 Features + Leaves maximum floor and wall space for furniture, decoration and fittings + Very compact casing (only 960 mm width) + Extremely quiet in operation both indoors and outdoors + Automatic air flow director ensures uniform air flow and temperature distribution + Air flow distribution for c...
Page 5 - Specifications; NOMINAL CAPACITY and NOMINAL INPUT
2 Specifications NOMINAL CAPACITY and NOMINAL INPUT For indoor units only: INDOOR UNITS FHYP35BV1 FHYP45BV1 FHYP60BV1 NOMINAL INPUT Cooling kW - - 0.115 Heating kW - - - For combination indoor + outdoor units (air cooled): INDOOR UNITS FHYP35BV1 FHYP45BV1 FHYP60BV1 OUTDOOR UNITS - - - CAPACITY (3) C...
Page 7 - TECHNICAL SPECIFICATIONS
TECHNICAL SPECIFICATIONS For indoor units only: INDOOR UNITS FHYP35BV1 FHYP45BV1 FHYP60BV1 DIMENSIONS Unit H mm 195 W mm 960 1,160 D mm 680 WEIGHT Unit kg 23 24 26 COLOUR Decoration panel White SOUND LEVEL Sound pressure (cooling/heating) (1) high dB(A) 37/37 38/38 low dB(A) 32/32 33/33 Sound power ...
Page 9 - ELECTRICAL SPECIFICATIONS; NOTES
ELECTRICAL SPECIFICATIONS For indoor units only: FHYP35BV1 FHYP45BV1 FHYP60BV1 CURRENT Nominal running current cooling/heating A See chapters RP-L7/B7, RYP-L7/B7, RYEP-L7, RZP-D Maximum running current cooling/heating A See chapters RP-L7/B7, RYP-L7/B7, RYEP-L7, RZP-D For combination indoor units + ...
Page 11 - Dimensional drawings
3 Dimensional drawings FHYP35 ∼ 45BV1 View from the front 780 From the floor side 2500 or more (Required space) Note: 1. Location of unit’s name plate: bottom of fan housing inside the suction grille. 2. In case of using infrared remote control, this position will be a signal receiver. Refer to the ...
Page 13 - Piping diagrams
4 Piping diagrams O Check valve L Flare connection M Screw connection N Flange connection Z Pinched pipe P Spinned pipe Indoor heat exchanger Field piping 4D024085A FHYP35 ∼ 125B Field piping Refrigerant pipe connection port diameters Model A B FHYP35-45BV1 6.4 12.7 FHYP60-71BV1 9.5 15.9 FHYP100-125...
Page 14 - Wiring diagrams
5 Wiring diagrams 3D027503-1 FHYP35 ∼ 125BV1 1-RED, 2-WHITE, 3-BLACK 33A Limit switch (swing flap) A1P Printed circuit board C1R Capacitor (M1F) HAP Light emitting diode (service monitor green) HBP Light emitting diode (service monitor green) M1A Motor (swing flap) M1F Motor (indoor fan) Q1F Thermo ...
Page 15 - Sound level; Sound level data; Sound pressure spectrum; Cooling only
6 Sound level 6-1 Sound level data Model Sound pressure level Sound power level (H) (cooling/heating) 230V Measuring location 50Hz H (cooling/heating) L (cooling/heating) FHYP35B 37/37 32/32 53/53 FHYP45B 38/38 33/33 54/54 FHYP60B 38/38 33/33 54/54 FHYP71B 39/39 35/35 55/55 FHYP100B 42/42 37/37 58/5...
Page 16 - Heat pump
FHYP71BV1 FHYP125BV1 Octave band center frequency (Hz) Octave band center frequency (Hz) Octave band sound pressure level Octave band sound pressure level Heat pump Octave band sound pressure level FHYP100BV1 Octave band center frequency (Hz) 4D028355 4D028283 4D028284 approximate threshold hearing ...
Page 17 - Air flow patterns
7 Air flow patterns FHYP35-45BV1 Cooling - air velocity distribution Air flow direction: horizontal FHYP35-45BV1 Cooling - air temperature distribution Air flow direction: horizontal 4D028550 • Ceiling Suspended Unit • R-407C • FHYP35-125BV1 1 7 15 • Split - Sky Air • Indoor Units
Page 25 - Accessories; Standard accessories; Optional accessories
8 Accessories 8-1 Standard accessories Name j 1 Drain hose j 2 Clamp j 3 Washer for hanging bracket j 4 Clamp j 5 Washer fixing plate Quantity 1 pc. 1 pc. 8 pcs. 6 pcs. 1 pc. Shape Name Insulation for fitting Sealing pad (Other) + Installation manual + Operation manual Quantity 1 of each 1 pc. Shape...
Page 26 - Specifications EKRORO
Specifications EKRORO Wire specifications Connector (White) White connect to indoor PCB (X40A) connect to on/off switch AWG24 0.22mm 2 White * Input ’ON’ = closed contact. Forced off On/off operation Input ’on’ stops operation + disables control Input off → on: starts operation, remote control is st...
Page 27 - Control systems; Wired remote control
9 Control systems 9-1 Wired remote control 6.5 x 9 (Round end slit) Cover open Cover closed 5 x 7 (Round end slit) Hole J 5 5 x 10 (Round end slit) 3TW23651-2 BRC1D517 • Ceiling Suspended Unit • R-407C • FHYP35-125BV1 1 9 9-1 25 • Split - Sky Air • Indoor Units
Page 28 - Safety device settings; Installation
10 Safety device settings Model Safety devices 35 50 60 71 100 125 FHYP-BV1 Fuse − − − − − − Fan motor thermal fuse (°C) − − − − − − Fan motor thermal protector (°C) OFF: 130±5 ON: 83±20 OFF: 130±5 ON: 83±20 OFF: 130±5 ON: 83±20 OFF: 130±5 ON: 83±20 OFF: 130±5 ON: 83±20 OFF: 130±5 ON: 83±20 3D006611...