Page 2 - TA B L E O F C O N T E N T S; Hydronic systems
1 TA B L E O F C O N T E N T S Split, Multi Split & Sky Air R-410A 1. 4MK58,75,90AZVMB / 3MX52AZVMB / 4MX68,80AZVMB Multi, inverter controlled unit 2. RX50,60,71AZVMB Pair, inverter controlled unit 3. Indoor unitsFTK25,35,50,60AZVMB / FTX25,35,50,60,71AZVMB Wall mounted, inverter controlled unit...
Page 3 - Inverter Multi Systems on R-410A
2 1 Inverter Multi Systems on R-410A BACKGROUND In 2002 Daikin will supplement the existing R-22 range of Multi inverter systems with new HFC R-410A Multi inverter systems featuring high COP values (up to 3.5 in cooling and 4.1 in heating!) andnew user friendly functions.A variety of different indoo...
Page 7 - DAY
6 • c. Night quiet mode (only for cooling mode) It is possible to reduce outdoor unit sound level automatically by removing a jumper wire in the outdoor unit. This function only works in cooling mode.Night mode automatically starts when the outdoor temperature has dropped by 5°C (or more, depending ...
Page 10 - Pair, inverter controlled outdoor units
9 2 R X 5 0 - 7 1 A Z V M B Pair, inverter controlled outdoor units BACKGROUND As well as new Multi inverter units operating on R-410A, Daikin will also launch Pair heat pumpcombinations using R-410A, in 50 to 71 class sizes. MODEL RANGE RX50-71AZVMB Class Wall Mounted Floor standing Flexi type Outd...
Page 12 - I N D O O R U N I T S
11 3 I N D O O R U N I T S BACKGROUND The new Multi and Pair inverter units on R-410A, described in chapter 1 and 2, utilise a new methodof communication. As a result, dedicated indoor units, not interchangeable with the current inverterindoor units, must be used, not interchangeable even with curre...
Page 14 - inverter controlled unit
13 F T K / F T X 2 5 - 7 1 A Z V M B FEATURES FTK/FTX25-35AZ FTK/FTX50-60-71AZ • Inverter powerful mode • Inverter powerful mode • Movement sensor • Home leave operation • Home leave operation • Outdoor unit silent operation • Outdoor unit silent operation • Indoor unit silent operation • Indoor uni...
Page 22 - Sky Air Super Inverter
21 4 R Z P 7 1 - 1 2 5 D V 1 Sky Air Super Inverter BACKGROUND After the success of the inverter in the residential market, Daikin has decided to introduce the firstSky Air inverter in Europe for the light commercial market (shops, small offices). This will enableDaikin to take the lead in promoting...
Page 25 - R M X 1 4 0 J Z V M B; Super Multi Plus, Inverter controlled - heat pump
24 5 R M X 1 4 0 J Z V M B Super Multi Plus, Inverter controlled - heat pump BACKGROUND After the successful introduction of the RMX140JVMB, Daikin has now launched its RMX140JZVMBwith R-407C refrigerant. MODEL RANGE OUTDOOR UNIT Heat pump MODEL NAME RMX140JZVMB CONNECTABLE INDOOR UNITS 25 class FTX...
Page 27 - C O M B I N AT I O N TA B L E S
26 FT1 8GV1B9 FT1 8JV1B A N25A V1B A N25A V1B9 FT25GV1B9 FT25JV1B A N35A V1B A N35A V1B9 FT35GV1B9 FT35JV1B FT40GV1B FT45G( A )V1B FT60G( A )V1B FV25D7V1 ( 2 ) FV35D7V1 ( 2 ) FV45D7V1 ( 2 ) FV60D7V1 ( 2 ) FL25G( A )V1N B FL35G( A )V1N B FL40G( A )V1N B FL45G( A )V1N B FHC35FJ7V1 FHC35BJV1 FHC35B7V1 ...
Page 32 - -way blow ceiling suspended cassette
31 7 F U Y P 7 1 - 1 2 5 B V 1 7 4-way blow ceiling suspended cassette BACKGROUND This new 4-way blow ceiling suspended cassette will replace the current FUYP-BV1 and is connectableto R-407C Sky Air and VRV outdoor units by means of a junction box. MODEL RANGE BEV71-140KVE FEATURES • Group control w...
Page 50 - chillers using R-134a
49 1 6 EUW(L)*40-200MXY1/T1 BACKGROUND The current EUW(L)*40-200KX series will be replaced by the new MX series. These chillers contain the new G-type compressor and are equipped with the new pCO 2 controllers (see chapter 17). Water-cooled water chillers Remote condenser chillers EUW40MXY EUW40MXT ...
Page 54 - Low wall unit / flexi type unit
53 1 8 F W V / F W H 1 - 1 0 C ( F ) 6 V 1 BACKGROUND A completely new range of fan coils will be available by spring next year. Main features of theseunits will be their low sound level, their new modern design and controls.Moreover, each model will be available in 7 capacity versions, both 2- and ...
Page 56 - Concealed ceiling unit
55 1 9 F W D 4 - 1 8 A ( F ) 6 V 1 BACKGROUND Next spring, to expand the range of existing duct units (FWM), Daikin will introduce a range of high ESP fan coil units. FWD4A(F)6V1FWD6A(F)6V1FWD8A(F)6V1FWD10A(F)6V1FWD12A(F)6V1FWD16A(F)6V1FWD18A(F)6V1 MODEL RANGE FEATURES • extension of the range up to...
Page 60 - MEASURING CONDITIONS; POWER SUPPLY
59 MEASURING CONDITIONS COOLING ONLY 1) nominal cooling capacities are based on: indoor temperature 27°CDB/19°CWB outdoor temperature 35°CDB refrigerant piping length 7.5m - 8/5m VRV level difference 0m HEAT PUMP 1) nominal cooling capacities are based on: indoor temperature 27°CDB/19°CWB outdoor te...
Page 61 - NOTES