Page 2 - Product Specifications; Outdoor Units; Max Connected Capacity; Connections; Operating Range - Cooling; Piping Dimensions; Power Supply; Indoor Wall-Mounted Units; Model Name; Outdoor Unit Compatibility
2 www.daikincomfort.com SS-MXS SS-MXS www.daikincomfort.com 3 Product Specifications Outdoor Units Model Name 2MXS18NMVJU 3MXS24NMVJU 4MXS36NMVJU RMXS48LVJU Cooling Capacity (Rated - Max) BTU/h 18,000-21,000 24,000-30,000 36,000-38,000 48,000 Heating Capacity (Rated - Max) BTU/h 18,900-25,000 24,000...
Page 3 - Indoor Slim-Duct Units
2 www.daikincomfort.com SS-MXS SS-MXS www.daikincomfort.com 3 Product Specifications Indoor Slim-Duct Units Model Name FDXS09LVJU FDXS12LVJU CDXS15LVJU CDXS18LVJU CDXS24LVJU Outdoor Unit Compatibility 2MXS18NMVJU 2MXS18NMVJU 2MXS18NMVJU 3MXS24NMVJU 3MXS24NMVJU 3MXS24NMVJU 3MXS24NMVJU 4MXS36NMVJU 4MX...
Page 4 - Piping Requirements; BP Units; Power Consumption
4 www.daikincomfort.com SS-MXS SS-MXS www.daikincomfort.com 5 Product Specifications Piping Requirements Allowable Length Details Maximum allowable length Between outdoor and BP units Total piping length Piping length between outdoor and BP units ≤ 180 ft (55 m) -[Example] a+b+c+d+e ≤ 180 ft Between...
Page 5 - Dimensions — Slim-Duct Indoor Units
4 www.daikincomfort.com SS-MXS SS-MXS www.daikincomfort.com 5 Dimensions — Slim-Duct Indoor Units FDXS09/12LVJU SIGNAL TRANSMITTER 11/16 (18mm) 2-5/16 (58mm) 7-3/8 (187mm) PROTECTION NET 10 AIR FILTER (ACCESSORY) 9 SUSPENSION BRACKET 8 POWER SUPPLY CONNECTION 7 INFRARED RECEIVER UNIT CONNECTION 6 CO...
Page 7 - Dimensions — Wall-Mount Indoor Unit
6 www.daikincomfort.com SS-MXS SS-MXS www.daikincomfort.com 7 Dimensions — Wall-Mount Indoor Unit CTXS07LVJU, FTXS09/12LVJU FRONT GRILLE FIXED SCREWS (INSIDE) FLAPS WIRELESS REMOTE CONTROLLER (ARC452A21) (SP ACE FOR PERFORMANCE) (SPACE FOR MAINTENANCE) (SPACE FOR MAINTENANCE) INTELLIGENT EYE SENSOR ...
Page 9 - Dimensions — Floor-Standing Indoor Units
8 www.daikincomfort.com SS-MXS SS-MXS www.daikincomfort.com 9 Dimensions — Floor-Standing Indoor Units FVXS18NVJU 27-9/16 (700mm) → → → ← OPERATION LAMP TIMER LAMP 8-1/4 (210mm) ROOM TEMP. THERMISTOR SIGNAL RECEIVER 3-3/4 (95mm) (HALF CONCEALED) INDOOR UNIT ON/OFF SWITCH 25-3/8 (644mm) LIQUID PIPE (...
Page 10 - Wiring Diagrams — Indoor Units
10 www.daikincomfort.com SS-MXS SS-MXS www.daikincomfort.com 11 Wiring Diagrams — Indoor Units CTXS07LVJU, FTXS09/12LVJU 1 X1M PCB1 PCB3 S46 S49 2 H1 BLK 1 1 BLK 1 3 ~ BLK 3.15A WHT OUTDOOR 2 BLK C102 V1 BLK RED 3 - H2 MR10 BLK GRN BLK FIELD WIRING. BLK C101 BLK H3 9 9 BLK FG SW1 S21 t˚ S1 HA 7 RED ...
Page 11 - Wiring Diagram — Indoor Units
10 www.daikincomfort.com SS-MXS SS-MXS www.daikincomfort.com 11 Wiring Diagram — Indoor Units X1M A1P 1 K L B 1 A2P H1 2 WHT 2 → F1U 3 V1TR RED 3 OUTDOOR 3.15A LED LED LED S1 S26 GRN H2 1 1 FIELD WIRING. P 1 H P 2 H P 3 H GRN/YLW TERMINAL FOR CENTRALIZED CONTROL H3 CAUTION ( ) GND NOTE THAT OPERATIO...
Page 13 - Wiring Diagram — Outdoor Units; NM; LED; UV; INDOOR; FIELD
12 www.daikincomfort.com SS-MXS SS-MXS www.daikincomfort.com 13 Wiring Diagram — Outdoor Units 2M XS18 NM VJ U GRN/YL W M1C PCB2 SW6 SW4 SW2 X1M LED PO WER SUPPL Y 5 SW5 A 4 2 3 SW3 SW1 1 BRN L1 L1 BLU M1F S2 L2 L2 S501 S502 11 1 5 1 Z2C N=4 MS BLK BLU RED YLW BLU RED YLW WHT X2M 1 1 Y1S X11A GRN BL...
Page 14 - Wiring Diagrams — Outdoor Units; PO; OUTDOOR; SHEET MET
14 www.daikincomfort.com SS-MXS SS-MXS www.daikincomfort.com 15 Wiring Diagrams — Outdoor Units 3M XS24 NM VJ U GRN/YL W M1C PCB2 SW2 SW6 SW4 X1M PO WER SUPPL Y LED 1 4 SW1 2 5 SW5 3 SW3 A L1 L1 BRN BLU M1F S2 L2 L2 S501 S502 11 1 5 1 MS BLU RED YL W BLK WHT X2M 1 1 Y1S X11A GRN GRN 2 2 PCB1 3 E2 E1...
Page 15 - WV
14 www.daikincomfort.com SS-MXS SS-MXS www.daikincomfort.com 15 Wiring Diagram — Outdoor Units 4M XS36 NM VJ U GRN/YL W M1C PCB2 SW4 SW2 SW6 LED PO WER SUPPL Y X1M 5 SW1 SW3 1 2 BRN SW5 A 3 4 L1 L1 BLU M1F S2 L2 L2 S501 S502 1 5 11 1 Z2C N=4 MS BLU RED BLK YLW WHT X2M SKY BLU 1 1 Y1S X11A RED GRN OR...
Page 16 - PB; • Houston, Texas • Printed in the USA.; Wiring Diagram — Outdoor Unit; Indoor Unit; Condensate Pump with Integral Float Switch; BP Unit; REFNET Joint; Outdoor Unit; Powder Coated Wall Mounted Bracket
16 www.daikincomfort.com SS-MXS SS-MXS www.daikincomfort.com PB Our continuing commitment to quality products may mean a change in specifications without notice. © 2015 • Houston, Texas • Printed in the USA. Wiring Diagram — Outdoor Unit Accessories Indoor Unit BRC1E72 Wired Navigation Remote Contro...