Daikin EWAQ130DAYN- Manuals
Daikin EWAQ130DAYN– User Manual in PDF format online.
Manuals:
User Manual Daikin EWAQ130DAYN
Summary
Table of Contents AIR COOLED MULTIPLE SCROLL CHILLERS 2 TECHNICAL DATA 11 EWAQ-DAYN EWYQ-DAYN 1. Features 12 54 2. Specifications Technical Specifications Electrical Specifications 13 13 14 55 55 57 3. Options Options 15 15 58 58 4. Capacity tables Cooling capacity tables Heating capacity tables Capaci...
Air Cooled Multiple Scroll Chillers Wide application range 04 Multiple scroll EWAQ080-260DAYN Cooling only Multiple scroll EWYQ080-250DAYN Heat pump EWAQ-DAYN N = Standard model EWAQ-DAYN P = Standard model + single pump (OPSP) EWAQ-DAYN B = Standard model + single pump (OPSP) + buffer tank (OPBT ) D...
06 Integrated hydronics The multiple scroll chillers come with various associated hydronic component packages to suit customer requirements. Standard fitted hydronics – water filter, air purge and flow switch – are fully integrated within the chiller unit and additional space is available for further o...
(1) (2) 20 25 30 35 40 0 -2 -4 -6 Low operational sound level Sound suppression is given high priority by Daikin. For those particularly sound sensitive applications where the standard average sound level of 89 dBA does not offer the desired sound level, OPLN (option low noise) further reduces the op...
Electronic Control Optional Gateway (not necessary for Modbus) RS485 Network BACnet LONWORKS MODBUS OPEN NETWORK BACnet® (8 chillers) LONWORKS® (8 chillers) MODBUS (32 chillers) F1/F2 F1/F2 F1/F2 Fire alarm Security Power supply facility › Elevator › Pump › Lighting › … Etc DIII-Net Optional RS485 N...
Daikin integrated chiller network (DICN) The Daikin in-house developed hardware and software offers the possibility of DICN functionality, allowing simultaneous operation of up to 4 chillers. By using the optional address card EKACPG (one per integrated chiller), the DICN enables you to operate a 1.1...
• Hydronic Systems • Single Unit 11 • Single Unit • Air cooled chiller, multiple scroll • EWAQ-DAYN TABLE OF CONTENTS EWAQ-DAYN 1 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 2 Specifications . . . . . . . . . . ....
• Single Unit • Air cooled chiller, multiple scroll • EWAQ-DAYN • Hydronic Systems • Single Unit 12 1 Features 1 1 S i n g l e U n i t H y d r o n i c S y s E W A Q - D A Y N A i r c o o l e d • Wide capacity range: 80 to 260kW with 8 cooling only models • Optimised for use with R-410A • Multiple re...
• Hydronic Systems • Single Unit 13 • Single Unit • Air cooled chiller, multiple scroll • EWAQ-DAYN 2 Specifications 1 2 2-1 Technical Specifications EWAQ080DAYN EWAQ100DAYN EWAQ130DAYN EWAQ150DAYN EWAQ180DAYN EWAQ210DAYN EWAQ240DAYN EWAQ260DAYN Cooling capacity Nom. kW 80 (1) 105 (1) 131 (1) 152 (1...
• Single Unit • Air cooled chiller, multiple scroll • EWAQ-DAYN • Hydronic Systems • Single Unit 14 2 Specifications 1 2 Notes (1) Cooling: entering evaporator water temp. 12ºC; leaving evaporator water temp. 7ºC; ambient air temp. 35ºC; standard: Eurovent (2) Cooling: entering evaporator water temp...
• Hydronic Systems • Single Unit 15 • Single Unit • Air cooled chiller, multiple scroll • EWAQ-DAYN 3 Options 3 - 1 Options 1 3 7:( (:$4'$<1 7(&+1,&$/63(&,),&$7,216237,216 2363 236323%7 8QLWV (:$4'$<1 (:$4'$<1 (:$4'$<1 (:$4'$<1 :HLJKW $GGLWLRQDOPDFKLQHZHLJKW NJ $GGLWLR...
• Hydronic Systems • Single Unit 21 • Single Unit • Air cooled chiller, multiple scroll • EWAQ-DAYN 4 Capacity tables 4 - 1 Cooling Capacity Tables 1 4 (:$4'$<1 7:' 67$1'$5' 7DPE& /:( 6L]H && 3, && 3, && 3, && 3, && 3, && 3, 6<0%2/6 127(6 &a...
• Hydronic Systems • Single Unit 23 • Single Unit • Air cooled chiller, multiple scroll • EWAQ-DAYN 4 Capacity tables 4 - 2 Capacity Correction Factor 1 4 4TW50689-8 CORRECTION FACTOR FOR GLYCOL Ethylene glycolPropylene glycol Legend Correction on cooling capacityCorrection on power inputCorrection ...
• Single Unit • Air cooled chiller, multiple scroll • EWAQ-DAYN • Hydronic Systems • Single Unit 24 5 Dimensional drawings 5 - 1 Dimensional Drawings 1 5 EWAQ080-100DA Y N(P-B) 01 Ev a por a tor 0 2 Condensor 03 Co m pressor 04 Exp a nsion v a lve + si g ht g l a ss 05 Disch a r g e stopv a lve (Opt...
• Single Unit • Air cooled chiller, multiple scroll • EWAQ-DAYN • Hydronic Systems • Single Unit 28 6 Piping diagrams 6 - 1 Piping Diagrams 1 6 EWAQ080-100DA Y N(N-P-B) (piping di a gr am ) 3TW57575-1 BRAND DESIGNATION M11-1 2C C om p ressor motors B1 P H High p ressure sensor M13-16F Fan motors B1 ...
• Hydronic Systems • Single Unit 31 • Single Unit • Air cooled chiller, multiple scroll • EWAQ-DAYN 6 Piping diagrams 6 - 1 Piping Diagrams 1 6 EWAQ-EW Y Q-DA Y N(N-P-B)(w a ter piping di a gr am ) 3TW57575- 2A W ater in Filter O p tional Shut off v al v e : C heck v al v e : Flange conn. : Flare C ...
• Single Unit • Air cooled chiller, multiple scroll • EWAQ-DAYN • Hydronic Systems • Single Unit 32 7 External connection diagrams 7 - 1 External Connection Diagrams 1 7 Translation of this legend can be found in the installation manual. Refer to the installation manual for instructions how to confi...
• Hydronic Systems • Single Unit 33 • Single Unit • Air cooled chiller, multiple scroll • EWAQ-DAYN 8 Sound data 8 - 1 Sound Power Spectrum 1 8 NOTES ! $ $ & '<>?@&[! \&[ & !"#$%&' ($%&' & ) *+ +, ,, *,,, +,,, .,,, 7,,, '\]^?_`j`{\^|} j j j '\]^?_``{\^|} ...
• Single Unit • Air cooled chiller, multiple scroll • EWAQ-DAYN • Hydronic Systems • Single Unit 34 9 Installation 9 - 1 Fixation and Foundation of Units 1 9 EWAQ -EWYQ 080-150DA Y N(N-P- B) 4TW57599-1 Fix a nchor bolts into the concrete f ound a tion. The concrete f ound a tion should be hi g her t...
• Hydronic Systems • Single Unit 37 • Single Unit • Air cooled chiller, multiple scroll • EWAQ-DAYN 9 Installation 9 - 2 Water Charge, Flow and Quality 1 9 ITEMS (1) (5) Cooling water (3) Cooled water Heated water (2) Tendency if out of criteria Circulating system Once flow Low temperature High temp...
• Single Unit • Air cooled chiller, multiple scroll • EWAQ-DAYN • Hydronic Systems • Single Unit 38 10 Operation range 10 - 1 Operation Range 1 10 EWAQ080-100-180-210-240-260DA Y N(N-P-B) 4TW57593-1B Le a ving ev a por a tor w a ter te m per a ture (°C) S TD: S t a nd a rd unit OPZL: Le a vin g wa t...
• Single Unit • Air cooled chiller, multiple scroll • EWAQ-DAYN • Hydronic Systems • Single Unit 40 11 Hydraulic performance 11 - 1 Water Pressure Drop Curve Evaporator 1 11 EWAQ080-100DA Y N(N-P-B) 4TW57579-5 W a ter flow through Ev a por a tor [l/ m in] 1. EWAQ080DA Y N* 2. EWAQ100DA Y N* W a rnin...
• Hydronic Systems • Single Unit 43 • Single Unit • Air cooled chiller, multiple scroll • EWAQ-DAYN 11 Hydraulic performance 11 - 2 Static Pressure Drop Unit 1 11 (:$4'$<1 7: 127(6 (:$4'$<123+3 (:$4'$<123+3 (:$4'$<123+3 (:$4'$<123+3 :$51,1* 6HOHFWLQJDÀRZRXWVLGHWKHFXUYHVFDQFDXVHGDPDJHW...
• Single Unit • Air cooled chiller, multiple scroll • EWYQ-DAYN • Hydronic Systems • Single Unit 66 4 Capacity tables 4 - 2 Heating Capacity Tables 2 4 (:<4'$<1 7:% +($7,1* 7DPE& /:& 6L]H +& 3, +& 3, +& 3, +& 3, +& 3, +& 3, +& 3, +& 3, +& 3, 6<0%...
Daikin Manuals
-
Daikin 3MXS68G2V1B
Installation Manual
-
Daikin 3P207257-3
Installation Manual
-
Daikin 4MKS75F2V1B
User Manual
-
Daikin 2AMX50G3V1B
Installation Manual
-
Daikin ACEF 3AV1-(C)(H)
User Manual
-
Daikin ACEF 3AVE
User Manual
-
Daikin ACEF 4AV1-(C)(H)
User Manual
-
Daikin 4MXS68F2V1B
User Manual
-
Daikin AGZ 130D
Installation Manual
-
Daikin AGZ 140D
User Manual
-
Daikin AH123E35AX
User Manual
-
Daikin AGZ030EH
Installation Manual
-
Daikin AGZ 040D
Installation Manual
-
Daikin Altherma HT
Installation Manual
-
Daikin AKZJ8Series
User Manual
-
Daikin Altherma Large Monobloc
User Manual
-
Daikin ARC423A17
User Manual
-
Daikin ARC433B46
User Manual
-
Daikin ARC433B47
User Manual
-
Daikin Altherma LT
User Manual