Page 2 - Heat pump solution; to fit botH; Heating; High Quality, Innovative Products; Advantages over; did You Know...
2 ™ Heat pump solution to fit botH new build Homes and tHe Harder to Heat older properties Heating COOLing High Quality, Innovative Products Innovation and quality are constantly at the forefrontof Daikin’s philosophy. Daikin’s systems provide highlyefficient solutions, which minimize the impact on ...
Page 3 - DOMeStiC HOt WateR PRODUCtiOn; Page 4
3 3 in 1 SYSteM FOR neW COnStRUCtiOn & RenOVatiOn MORe COMFORt > LOW eneRgY COnSUMPtiOn > FeWeR CO > 2 eMiSSiOnS DOMeStiC HOt WateR PRODUCtiOn 1. Page 4 tHe 3 in 1 gUaRantee FOR abSOLUte COMFORt 2. Page 6 tHe baSiCS 3. Page 10 teCHniCaLLY 4. Page 18 eCOnOMiCaLLY 5. Page 19 aPPLiCatiOnS ...
Page 4 - heats; eneRgY eFFiCient OPeRatiOn; Daikin Heat PUMP exPeRienCe; tHe 3 in 1 Guarantee
4 Daikin Altherma TM is an innovative system that heats , produces domestic hot water and can even cool spaces. Daikin Altherma TM offers your customer maximum comfort the whole year through. These heat pumps are also an interesting alternative for classic gas or fuel oil heating as they offer your ...
Page 5 - daiKin offers tHe; complete renewable solution; for Home HeatinG and Hot water; Daikin Altherma; Benefits for; How Heat Pumps Work; STAGE ONE
5 daiKin offers tHe complete renewable solution for Home HeatinG and Hot water Daikin Altherma TM Benefits for New Construction and RetrofitInstallations Cost effective installations Inverter technology and weather compensation as standard Low energy consumption Reduced CO2 emissions Safe,...
Page 6 - Daikin aLtHeRMa; SPLit tYPe; Application; Heat pump type; Daikin offers you the choice between a Daikin altherma; In addition, the Split system can be connected to:; outdoor & indoor unit
6 Daikin aLtHeRMa tM SPLit tYPe Application Heating and (optional) cooling (+ domestic hot water) Heat pump type Outdoor (compressor) unit + Indoor (hydronic parts) unit R-410A refrigerant piping Between outdoor unit and indoor unit H 2 O piping Between indoor unit and indoor heating appliances Inst...
Page 7 - MOnObLOC; monobloc outdoor unit; In addition, the monobloc system can be connected to:; tHe basics
7 Daikin aLtHeRMa tM MOnObLOC Application Heating and (optional) cooling (+ domestic hot water) Heat pump type Outdoor unit only (compressor and hydronic parts combined) R-410A refrigerant piping Inside outdoor unit H 2 O piping Between outdoor unit and heating terminal units Installer’s advantages ...
Page 8 - The system consists of 5 components which together to
8 Fan CoilUnit (field supply) Low temperature radiator (field supply) Under Floor Heating System (field supply) 2 / Domestic hot water tank 2B / Solar kit option 1B / Hydrobox 1A / Outdoor unit 1A / OUtDOOR Unit : an eFFiCient USe OF eneRgY FROM tHe aiR Daikin Altherma TM uses a natural source of en...
Page 9 - MOnObLOC OUtDOOR Unit: aLL in One; In addition to Daikin Altherma; Split type systems,; SOLaR COnneCtiOn kit; ROOM tHeRMOStat
9 3 / Monobloc outdoor unit 3 / MOnObLOC OUtDOOR Unit: aLL in One In addition to Daikin Altherma TM Split type systems, Daikin has a monobloc version in which the hydrobox components are located within the outdoor unit. In this new system, the water pipes, rather than refrigerant 4 / SOLaR COnneCtiO...
Page 10 - heat pump is also largely attributable to; HigH eFFiCienCY COMPReSSORS:; tHe OUtDOOR Unit; Compact, weather-resistant and easy to install
10 3.tecHnicallY SUPeR PeRFORManCe tHankS tO tHe inVeRteR PRinCiPLe The coefficient of performance (COP) of the Daikin Altherma TM heat pump is also largely attributable to the Daikin inverter principle. An integrated frequency-converter adjusts the rotational speed of the compressor to suit the hea...
Page 11 - Heating and Cooling; Set temperature limits; HYDRObOx; tecHnicallY
11 Available in two versions: EKHBH for heating > only, EKHBX for heating and cooling Built-in electric back-up heater for additional > heating during extremely cold outdoor temperatures or as back-up in case of problems with the outdoor unit 2 shut-off valves to assemble the water outlet and ...
Page 12 - tHe USeR inteRFaCe
12 tHe USeR inteRFaCe With the easy to reach digital user interface in the indoor unit, controlling the Daikin Altherma TM system is also simple for your customer. The display offers a great deal of useful information: Day of the week > Time > Operating mode > (heating or cooling, heating d...
Page 13 - The Daikin Altherma; monobloc is available in
13 2 - Daikin aLtHeRMa tM MOnObLOC aiR-tO-WateR Heat PUMP High efficiency compressor 1. Expansion tank 2. Tank with back up heating 3. Pressure gauge (water circuit) 4. Refrigerant connection 5. All hydronic parts are located within the outdoor unit > H > 2 O piping between outdoor unit and in...
Page 14 - - tHe DOMeStiC HOt WateR tank
14 3 - tHe DOMeStiC HOt WateR tank Field supply 1. Hot water connection (H) 2. Pressure relief valve connection 3. Pressure relief valve (field supply) 4. Electrical box 5. Electrical box lid 6. Recirculation hole 7. Thermistor socket 8. Flow inlet connection (F) (from main unit) 9. Heat exchanger c...
Page 15 - Your customers with a solar boiler can; MULtiFUnCtiOnaL HOt WateR tank ...; No natural gas or fuel oil connection or exhaust
15 did You Know… Your customers with a solar boiler can enjoy wonderful hot water at any time, even when the sun is not shining? An integrated re-heater is included in the system to help the sun on cloudy days. MULtiFUnCtiOnaL HOt WateR tank … Stainless steel > Daikin offers a tank made of stainl...
Page 16 - SOLaR tHeRMaL bOiLeR; SOLaR kit; solar boiler assembly; SOLaR SYSteM; Available with all models
16 SOLaR tHeRMaL bOiLeR Averaged over an entire year, the sun delivers half of the energy we need to bring our domestic water up to the desired temperature for free. Your customer can use this solar energy by connecting a solar boiler to the Daikin Altherma TM system. A solar boiler is a thermal sol...
Page 17 - - tHe ROOM tHeRMOStat
17 did You Know tHat… Daikin has set up a number of monitoring sites (in Europe, Oregon, New Hampshire, Alaska, ...), where Daikin Altherma has been tested under totally different climate conditions. High satisfaction has been achieved with increased comfort, stable indoor temperature, low energy co...
Page 18 - How We Use Energy in Our Homes; debuted in Europe in 2006 and since; 6 To 80% Additional Heat; PER; LOWeR CO; produces no direct CO
18 0 1000 2000 3000 4000 5000 6000 How We Use Energy in Our Homes Heating and cooling account for the largest portion of a typical utility bill. Source: 2007 Buildings Energy Data Book, Table 4.2.1., 2005 energy cost data. � Space Heating - 35.2% � Water Heating - 13.1% � Space Cooling - 10.8% � Lig...
Page 19 - Calculation of heat losses (Transmission and ventilation losses); DeSign SteP 3; SYSteM COnFigURatiOnS; SPaCe Heating WitH an aUxiLiaRY bOiLeR
19 Calculation of heat losses (Transmission and ventilation losses) MOnO-VaLent Uses heat pump energy only > Ideal for new construction > 100% heat pump coverage: selection of bigger > capacity and higher investment cost heat pump Define the leaving water temperature range of the necessary ...
Page 20 - Application “heating” and “production of domestic hot water”; SPLit tYPe aPPLiCatiOnS
20 2. Application “heating” and “production of domestic hot water” The temperature in each room is regulated by a valve on every water circuit. Hot water for domestic use is delivered by the domestic hot water tank connected to the indoor unit. Outdoor unit 1. Hydrobox 2. Heat exchanger 3. Pump 4. V...
Page 22 - MOnObLOC aPPLiCatiOnS
22 2. Application “heating” and “production of domestic hot water” The temperature in each room is regulated by a valve on every water circuit. Hot water for domestic use is delivered by the domestic hot water tank connected to the unit. Unit 1. Heat exchanger 2. Pump 3. Shut-off valve 4. Collector ...
Page 23 - Application “heating/cooling” without a room thermostat
23 3. Application “heating/cooling” via room thermostat and “production of domestic hot water” Heating using under floor heating loops and fan coil units. Cooling using only the fan coil units. Hot water for domestic use is delivered by the domestic hot water tank connected to the unit. 4. Applicati...
Page 24 - OUtDOOR MOnObLOC tYPe; OUtDOOR SPLit tYPe; OUtDOOR Unit; tecHnical specifications
24 OUtDOOR MOnObLOC tYPe HEATIng only REvERSIBlE SInglE PHASE With bottom plate heater EDlQ036BA6vJU EDlQ048BA6vJU EDlQ054BA6vJU EBlQ036BA6vJU EBlQ048BA6vJU EBlQ054BA6vJU Nominal capacity (3) Heating Btu/hr 38,200 47,700 54,600 38,200 47,700 54,600 Cooling Btu/hr - - - 43,800 54,500 57,000 Nominal i...
Page 25 - tecHnical specifications
25 tecHnical specifications EKHBH030BA3vJU EKHBX030BA3vJU EKHBH030B6vJU EKHBX030B6vJU Function Heating only Reversible Heating only Reversible Leaving water temperature range Heating °F (°C) (59) 77 - 131* ((15) 25 - 55) (59) 77 - 131* ((15) 25 - 55) Cooling °F (°C) - 41 - 71.6 (122) (5 - 22 (50)) -...
Page 27 - DOMeStiC HOt WateR tank
27 EKSolHWBAvJU Heat exchanger pressure drop psi 3.12 max.inlet temp °F (°C) 230 (110) heat exchange capacity W/K 1,400 Logarithmic mean temperature difference (LMTD) K 5 Pump Number of speeds 3 Power input W 46 Water circuit Piping connections diameter in. 3/4 FBSP Ambient temperature max. °F 95 (3...
Page 28 - PUMP StatiOn; OPtiOn LiSt
28 EKRTWA Ambient temperature Storage °F (°C) -4 - 140 (-20 - 60) Operation °F (°C) 32 - 122 (0 - 50) Temperature setpoint range Heating °F (°C) 39.2 - 98.6 (4 - 37) Cooling °F (°C) 39.2 - 98.6 (4 - 37) Clock yes Regulation function proportional band Dimensions (Net) HxWxD in. 3 27/64 x 4 59/64 x 1 ...
Page 29 - Control customized to your customer; system to the type of; Automatic re-start after power interruption; Every Daikin Altherma; system is equipped with a; with a Daikin Altherma; the temperature of the domestic; uniQue
29 ™ Control customized to your customer The water temperature changes in function with the outside temperature so that your customer can enjoy a stable level of heating at any time. As the installer, you set up the system according to the desires of your customer. You input four temperatures to det...
Page 31 - Single Split Systems; Quaternity; TM System; SkyAir Systems; otHer product lines available; Daikin Inverter Ducted System
31 Single Split Systems SeeR 18 Heat Pump FtxS/RxSCool Only FtkS/RkS 15+ Heat Pump FtxS/RxS 13 Concealed FDxS/RxS 13 Heat Pump Ftxn/RxnCool Only Ftkn/Rkn Capacity 9kbtu/h 12kbtu/h 15kbtu/h 18kbtu/h 24kbtu/h 450 sq. ft. 625 sq. ft. 813 sq. ft. 1,050 sq. ft. 1,460 sq. ft. SeeR 21+ Heat Pump Ftxg/Rxg C...
Page 32 - WaRningS
Daikin europe n.V. is approved by LRQa for its Quality Management System in accord-ance with the iSO9001 standard. iSO9001 pertains to quality assurance regarding design, development, manufacturing as well as to services related to the product. © 2010 Daikin industries, Limited. Daikin ® , Daikin aC...