Daikin EKHVMRD50AAV1- Manuals
Daikin EKHVMRD50AAV1– User Manual in PDF format online.
Manuals:
User Manual Daikin EKHVMRD50AAV1
Summary
E E D E N 1 1 - 7 2 7 D a i k i n A l t h e r m a F l e x T y p e Heating Technical Data EED_Heating_Spread.pdf 1 6/06/2011 10:29:48
1 • Table of Contents Daikin Altherma Flex Type • Heating • Daikin Altherma I Daikin Altherma Flex Type Indoor unit ...................................... 1 EKHVMRD-A .................. 3 2 EKHVMYD-A ................ 19 Outdoor unit ................................... 3 EMRQ-A ................ 35 Do...
• Heating • Daikin Altherma 3 • Outdoor flex • EKHVMRD-A TABLE OF CONTENTS EKHVMRD-A 1 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 2 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ....
• Indoor unit • EKHVMRD-A • Heating • Daikin Altherma 4 1 Features 1 1 H e a t i n g E K H V M R D - A • High temperature application: up to 80ºC without electric heater • Possible to choose between low temperature and high temperature heat emitters • Cost effective alternative to a fossil fuel boil...
• Heating • Daikin Altherma 5 • Indoor unit • EKHVMRD-A 2 Specifications 1 2 2-1 Technical Specifications EKHVMRD50AAV1 EKHVMRD80AAV1 Casing Colour Metallic grey Material Precoated sheet metal Dimensions Unit Height mm 705 Width mm 600 Depth mm 695 Packed unit Height mm 860 Width mm 680 Depth mm 800...
• Indoor unit • EKHVMRD-A • Heating • Daikin Altherma 6 2 Specifications 1 2 Notes (1) Maximum water flow rate for Dt: 5ºC (2) Sound level is valid in free field condition because it is measured in a semi-anechoic room. Measured value under actual installation conditions will be higher due to enviro...
• Heating • Daikin Altherma 7 • Indoor unit • EKHVMRD-A 3 Dimensional drawings 3 - 1 Dimensional Drawings 1 3 3TW59914-1A EKHVMRD50-80A left installation right installation Screw fixation of top plate(Both sides) Min. 500 Min. 600 〈 Space required for switch box removal) upwiring Model A B C EKHVMRD...
• Heating • Daikin Altherma 9 • Indoor unit • EKHVMRD-A 4 Piping diagrams 4 - 1 Piping Diagrams 1 4 EKHVMRD50-80AAV1 3TW59915-1A R7T Liquid thermistor R134a R6T Discharge thermistor R5T Leaving water thermistor R4T Returning water thermistor R3T Liquid thermistor R410A S1PH High pressure switch B1PL...
• Indoor unit • EKHVMRD-A • Heating • Daikin Altherma 10 5 Wiring diagrams 5 - 1 Wiring Diagrams - Single Phase 1 5 4TW59916-1A Legend * : included in option kit # : field supplied A1P : Main PCB A2P : User interface PCB A3P : control PCB A4P : Inverter PCB A5P : QA PCB A6P : Filter PCB A7P * : Digi...
• Indoor unit • EKHVMRD-A • Heating • Daikin Altherma 14 5 Wiring diagrams 5 - 2 Wiring Diagrams - Three Phase 1 5 EKBUH-AA6W1 P art number Descri p tion P art number Descri p tion A8 P Demand PC B (Indoor unit o p tion) K5M C ontactor for backu p heater (all p ole disconnection) E1H, E 2 H, E3H Bac...
• Heating • Daikin Altherma 15 • Indoor unit • EKHVMRD-A 6 External connection diagrams 6 - 1 External Connection Diagrams 1 6 EKHVM(R/Y)D 3TW59919-4A NOTE In case of signal cable or communication cable, kee p minimum distance to p ower cables > 2 5mm P lease check unit wiring diagram for more de...
• Indoor unit • EKHVMRD-A • Heating • Daikin Altherma 16 7 Sound data 7 - 1 Sound Power Spectrum 1 7 3TW59917-2 EKHVMRD50-80A Notes - Measured according to ISO3744- Reference acoustic pressure 0dB = 10E-6 μ W/m _ - dBA=A-weighted sound power level - Unit condition: Ta=7/6°C - Heating setpoint 55/65°...
• Heating • Daikin Altherma 17 • Indoor unit • EKHVMRD-A 7 Sound data 7 - 2 Sound Pressure Spectrum 1 7 3TW59917-1 EKHVMRD50-80A Notes - The above data is valid in free field condition, because it is measured in a semi-anechoic room. If sound is measured under actual installation conditions, the mea...
• Indoor unit • EKHVMRD-A • Heating • Daikin Altherma 18 8 Hydraulic performance 8 - 1 Static Pressure Drop Unit 1 8 3TW59919-5 1. The ESP curves are the maximum ESP curves for different DT types (pump rpm=4000 for _ T=5°C; pump rpm=3600 for _ T=10°C) The pump of the indoor module is inverter contro...
• Outdoor unit • EMRQ-A • Heating • Daikin Altherma 36 1 Features 3 1 H e a t i n g E M R Q - A • The ultimate flexible heating solution for apartment buildings and collective housiing • Customised to meet your building’s needs: 10 indoor units to be connected to 1 outdoor unit • Cost effective alte...
• Heating • Daikin Altherma 39 • Outdoor unit • EMRQ-A 3 Selection procedure 3 - 1 Selection Procedure 3 3 3TW59919-3A A Select required indoor unit capacity, based on design point for each apartment Required capacity >5,6kW or <5,6kWB Sum all required indoor unit capacities & capacity ind...
• Outdoor unit • EMRQ-A • Heating • Daikin Altherma 40 4 Combination table 4 - 1 Combination Table 3 4 3TW59919-2D REMARKS Other combinations are not guaranteed (1) For allowed installation, see Installation Manual( 2 ) Re q uires demand PC B EKR P 1AHTA (3) Re q uired to install to be able to conne...
• Heating • Daikin Altherma 41 • Outdoor unit • EMRQ-A 5 Capacity tables 5 - 1 Heating Capacity Tables 3 5 7D /:>&@ /:>&@ /:>&@ /:>&@ >&'%@ +& 3, +& 3, +& 3, +& 3, (054 (054 (054 (054 (054 (: & (: & (: & (: & ¨7 & ¨7 &...
• Heating • Daikin Altherma 43 • Outdoor unit • EMRQ-A 5 Capacity tables 5 - 1 Heating Capacity Tables 3 5 3TW59912-1 EMRQ8-16A Indoor unit type power consumption flowrate [l/min] *50* *80* n T = 15°C 5,4 8,6 n T = 10°C 8,0 12,9 n T = 5°C 16,1 25,8 Flowrate information Example (standard condition 7/...
• Outdoor unit • EMRQ-A • Heating • Daikin Altherma 44 5 Capacity tables 5 - 2 Cooling Capacity Tables 3 5 3TW59912-1 EMRQ8-16A Symbols CC Cooling capacity [kW] PI Power input [kW] LW Leaving water temperature EW Entering water temperature Conditions - n T(Entering water temperature - Leaving water ...
• Heating • Daikin Altherma 45 • Outdoor unit • EMRQ-A 5 Capacity tables 5 - 3 Capacity Correction Factor 3 5 3TW59912-2 EMRQ8A Capacity correction 1. Rate of change in heating capacity [Notes capacity correction] 1 These figures illustrate the rate of change in capacity α of a standard indoor unit ...
• Heating • Daikin Altherma 49 • Outdoor unit • EMRQ-A 7 Centre of gravity 7 - 1 Centre of Gravity 3 7 3TW59924-1 EMRQ8-16A Center of foundation bolt hole Center of foundation bolthole (Slot) Item A B EMR08,10,12AAY1 613 322 EMRQ14,16AAY1 609 313 Center of foundation bolthole (Slot) Center of founda...
• Heating • Daikin Altherma 53 • Outdoor unit • EMRQ-A 10 Sound data 10 - 1 Sound Power Spectrum 3 10 3TW59927-2 Sound power level(dB) Octave band center frequency (Hz) EMRQ8A NOTES 1 dBA = A-weighted sound power level (A-scale according to IEC) 2 Reference acoustic intensity 0dB = 10E-6 μ W/m _ 3 M...
• Heating • Daikin Altherma 55 • Outdoor unit • EMRQ-A 10 Sound data 10 - 2 Sound Pressure Spectrum 3 10 Octave band sound pressure level dB(0dB=0.0002 μ bar) EMRQ8A Location of microphone 3TW59927-1 Overall (dB) Scale 50Hz A 58 C 66 (B,G,N is already rectified) Measuring place Anechoic chamber (con...
• Heating • Daikin Altherma 57 • Outdoor unit • EMRQ-A 11 Installation 11 - 1 Installation Method 3 11 4TW59919-6A Heat/cooling meters - All meters are to be installed in field piping - For tank heat meter between tank and indoor unit Depending on the position of tank to indoor unit, the heat meter ...
• Outdoor unit • EMRQ-A • Heating • Daikin Altherma 60 11 Installation 11 - 2 Refrigerant Pipe Selection 3 11 4PW61262-1 Selection of piping material Note Piping and other pressure containing parts shall comply with the applicable legislation and shal be suitable for refrigerant. Use phosphoricacid ...
• Heating • Daikin Altherma 61 • Outdoor unit • EMRQ-A 11 Installation 11 - 2 Refrigerant Pipe Selection 3 11 4PW61262-1 Selection of piping size Note n Reversible indoor units (EKHVMYD) need 3 pipes. n Heating only indoor units (EKHVMRD) need 2 pipes (liquid and discharge only). n Size: determine t...
• Outdoor unit • EMRQ-A • Heating • Daikin Altherma 62 11 Installation 11 - 2 Refrigerant Pipe Selection 3 11 4PW61262-1 Selection of refrigerant branch kits Rrefrigerant refnets n When using refnet joint at the first branch counted from the outdoor unit side, choose from the following table in acco...
• Heating • Daikin Altherma 63 • Outdoor unit • EMRQ-A 11 Installation 11 - 2 Refrigerant Pipe Selection 3 11 4PW61262-1 System piping limitations Piping length restrictions Make sure to perform the piping installation within the range of the maximumallowable pipe length, allowable level difference ...
• Outdoor unit • EMRQ-A • Heating • Daikin Altherma 64 12 Operation range 12 - 1 Operation Range 3 12 3TW59913-1 Space heating mode Domestic hot water mode Startup area Continuous heating operation : Continuous heating operation : Startup area : operation possible, but no guarantee of capacity : Can...
• Heating • Daikin Altherma 67 • Domestic hot water tank • EKHTS-AC TABLE OF CONTENTS EKHTS-AC 1 Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68 2 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . ...
• Domestic hot water tank • EKHTS-AC • Heating • Daikin Altherma 70 3 Capacity tables 3 - 1 Heating Capacity Tables 4 3 3TW58802-1A Altherma HT-TW Domestic hot water tank The DAIKIN ALTHERMA heat pump in combination with the optional domestic hot water tank provide hot water for household usage.The ...
• Heating • Daikin Altherma 75 • Domestic hot water tank • EKHTS-AC 6 Piping diagrams 6 - 1 Piping Diagrams 4 6 EKHTS Water flow 3TW58805-1 R2T Domestic hot water thermistor M3S 3-way motorized valve Outdoor Indoor Field installation (delivered withEKHTS*) Shut off valve 3-way motorized valve Load O...
• Heating • Daikin Altherma 79 • Heat pump convector • FWXV-A 2 Specifications 5 2 2-1 For indoor units only FWXV15AVEB FWXV20AVEB Nominal input (Indoor only) Cooling kW 0.013 0.015 Heating kW 0.013 0.015 Heating capacity Total capacity Nom. kW 1.5 2.0 Water volume Nom. m 3 /hr 0.26 0.34 l/min 4.3 5...
• Heat pump convector • FWXV-A • Heating • Daikin Altherma 80 2 Specifications 5 2 Standard Accessories Item Installation manual Quantity 1 1 Item Operation manual Quantity 1 1 Item Wireless remote control Quantity 1 1 Item Batteries Quantity 2 2 Item Remote control holder Quantity 1 1 Item Drain ho...
• Heating • Daikin Altherma 81 • Heat pump convector • FWXV-A 3 Capacity tables 3 - 1 Heating capacity tables 5 3 FWXV15-20A Heating capacity tables Air temperature (°C) 20°C Water temperature (Entering °C - leaving °C) 35°C-30°C 45°C-40°C 50°C-45°C 55°C-45°C 60°C-50°C Model Fan Heating capacity Wat...
• Heat pump convector • FWXV-A • Heating • Daikin Altherma 82 3 Capacity tables 3 - 2 Cooling capacity tables 5 3 FWXV15-20A Cooling capacity tables Air temperature (°CDB-°CWB) 27°CDB-19°CWB Water temperature (Entering °C - leaving °C) 6°C-11°C 7°C-12°C 8°C-13°C 9°C-14°C Model Fan Total cooling capa...
• Heating • Daikin Altherma 83 • Heat pump convector • FWXV-A 4 Dimensional drawing & centre of gravity 4 - 1 Dimensional drawing 5 4 FWXV15-20A unit (mm) Drain socket Model name label Hole for piping Note) 1. The mark ( Y ) shows piping direction Indoor unit ON/OFF switch Hole for splint (Wall ...
• Heating • Daikin Altherma 85 • Heat pump convector • FWXV-A 5 Piping diagram 5 - 1 Piping diagram 5 5 FWXV15-20A 4D066467B Field p i p ing (1 2 .7 C uT) Field p i p ing (1 2 .7 C uT) W ater fl ow C ooling, heating 1 2 .7 C uT Heat exchanger Indoor unit 1 2 .7 C uT 6.4 C uT 6.4 C uT Header Header Tu...
• Heat pump convector • FWXV-A • Heating • Daikin Altherma 86 6 Wiring diagram 6 - 1 Wiring diagram 5 6 3D066232 FWXV15-20A Wiring diagram Field wiring Fan motorstand Indoor Infrared remote control R : Protective earth F1U ∼ F12U : Fuse H1P ∼ H2P : Pilot lamp MR10 : Magnetic relay V1, V2 : Varistor ...
• Heating • Daikin Altherma 87 • Heat pump convector • FWXV-A 7 Sound data 7 - 1 Sound pressure spectrum 5 7 3D066681 Octave band sound pressure level dB(0dB=0.0002 μ bar) Octave band center frequency (Hz) FWXV15A Overall (dB) Scale A 19 (B,G,N is already rectified) Measuring place Measure in anecho...
• Heat pump convector • FWXV-A • Heating • Daikin Altherma 88 8 Hydraulic performance 8 - 1 Static pressure drop unit 5 8 ):;9$ 7: 127( 7KLVJUDSKFDQEHXVHGWRFDOFXODWHWKHSUHVVXUHGURSRYHUWKHZD\YDOYH 7KHSUHVVXUHGURSRYHUWKH+HDW3XPS&RQYHFWRULVQRWLQFOXGHG 10 1 0.1 0.1 1 10 100 3UHVVXUHGURSRYHUZD\YDOYH ...
Daikin Manuals
-
Daikin 3MXS68G2V1B
Installation Manual
-
Daikin 3P207257-3
Installation Manual
-
Daikin 4MKS75F2V1B
User Manual
-
Daikin 2AMX50G3V1B
Installation Manual
-
Daikin ACEF 3AV1-(C)(H)
User Manual
-
Daikin ACEF 3AVE
User Manual
-
Daikin ACEF 4AV1-(C)(H)
User Manual
-
Daikin 4MXS68F2V1B
User Manual
-
Daikin AGZ 130D
Installation Manual
-
Daikin AGZ 140D
User Manual
-
Daikin AH123E35AX
User Manual
-
Daikin AGZ030EH
Installation Manual
-
Daikin AGZ 040D
Installation Manual
-
Daikin Altherma HT
Installation Manual
-
Daikin AKZJ8Series
User Manual
-
Daikin Altherma Large Monobloc
User Manual
-
Daikin ARC423A17
User Manual
-
Daikin ARC433B46
User Manual
-
Daikin ARC433B47
User Manual
-
Daikin Altherma LT
User Manual