Page 2 - Super Multi NX is the knowledgeable choice.
Air condition your home with a single outdoor unit. Air condition your home with a single outdoor unit. The Daikin Super Multi NX lets you build a highly efficient multi room air conditioning system by connecting up to four indoor units to a single outdoor unit. The series includes a wide variety of...
Page 3 - Contents
Contents Concepts Main features Product lineup Functions Specifications Options Capacity tables 3 5 9 19 23 26 27 2
Page 4 - Concepts; Key concepts for Super Multi NX; Enjoy the comfort and luxury of your dreams.
Concepts Key concepts for Super Multi NX Enjoy the comfort and luxury of your dreams. The DC motor, swing compressor and other advanced technologies make for energy-efficient operation that achieves high COPs. The quiet operation mode helps create a more pleasant living environment. DC inverter powe...
Page 5 - Connect 4 indoor units to a single outdoor unit
Concepts In 1969, Daikin developed the first multi room air conditioning system in Japan that needed just one outdoor unit. Over the ensuing 35 years, Daikin has built an enviable reputation with the constant progress of its technology. Super Multi NX requires only a single outdoor unit to maintain ...
Page 6 - Main features; High energy efficiency through advanced; High energy savings; Swing compressor; Daikin energy-saving technologies
5 2 1 3 What is COP? An air conditioner's COP (coefficient of performance) indicates how efficiently it uses energy. A high COP means high energy efficiency. COP = Capacity (W) Power consumption (W) Main features ntelligent technologies High energy efficiency through advanced technologies delivers h...
Page 7 - Convenient features to realise your; Indoor unit; DC inverter power control gives you greater comfort; Quiet operation; Outdoor unit; 2 dB (A) is so quiet you can even hear whispers
6 Main features deal environment Convenient features to realise your ideal environment Indoor unit During cooling operation Set temp. Temp. Time Starts Too cool Not cool DC inverter power control uses its full capacity at start-up to cool/warm quickly. As soon as the set temperature is reached, it c...
Page 8 - Stylish indoor units for elegant interiors
7 Only 240 mm is required above the ceiling for installation. The ample maximum piping length of 70 m permits more freedom in the placement of air conditioner units and facilitates the optimisation of interior space. Max. piping length Total For one room 25 m 3MKS58 3MXS52 50 m 3MKS75 3MXS68 60 m 4M...
Page 9 - Convenient remote controllers; Priority
8 Priority setting with Inverter Powerful Operation Priority setting with Outdoor Unit Quiet Operation When Inverter Powerful Operation is selected in the priority room, the indoor unit capacity in the priority room is increased by shifting capacity from units in other rooms. After 20 minutes, all u...
Page 10 - Possible combinations for indoor and outdoor units; Product lineup
9 Outdoor unit Indoor unit Connectable to up to 3 indoor units Wall-mounted type Connectable to up to 4 indoor units 7.1 kW 6.0 kW 5.0 kW 3.5 kW 2.5 kW Cooling only Heat pump FTKS35GVMA FTXS35GVMA FTKS25GVMA FTXS25GVMA FTKS20DVMA FTXS20DVMA Cooling only Heat pump FTKS71JVMA FTXS71JVMA FTKS60JVMA FTX...
Page 12 - Indoor unit lineup
11 Wall-Mounted Type 6.0 kW class FTKS60JVMA FTXS60JVMA 5.0 kW class FTKS50JVMA FTXS50JVMA 7.1 kW class FTKS71JVMA FTXS71JVMA Cooling only Heat pump 2.5 kW class FTKS25GVMA FTXS25GVMA 2.0 kW class FTKS20DVMA FTXS20DVMA 3.5 kW class FTKS35GVMA FTXS35GVMA Cooling only Heat pump GOOD DESIGNAWARD 2004 I...
Page 15 - Clean air; Versatile remote control; Stylish design
14 Indoor unit lineup Daikin’s inverter floor standing split systems are especially effective in heating. The unit features dual air outlets that diffuse warm, cosy air at low floor level—where you need it most in winter. This, combined with the vertical auto swing louvres on the top air outlet, pro...
Page 16 - More; Slim and compact design; AIR
15 Indoor unit lineup Models in the CDK(X)S-EA series are only 700 mm in width and 21 kg in weight, so are easily installed in limited spaces. Just 200 mm in height, all models can be installed in rooms with as little as 240 mm depth between the drop ceiling and ceiling slab, making them ideal for e...
Page 17 - Comfortable airflow
16 Indoor unit lineup FLXS25 37/31/ 28 dB(A) FLXS35 38/32/ 29 dB(A) FLXS50 47/39/ 36 dB(A) FLXS60 48/41/ 39 dB(A) (H/L/ SL ) The FLXS25 achieves the quiet sound level of 28 dB (A). Indoor Unit Quiet Operation decreases the operation sound by 2 or 3 dB (A) from the low setting fan speed. The rounded ...
Page 18 - Horizontal Flow; directions; T bar; Suitable for the light commercial market; Compact Multi Flow Ceiling-Mounted Cassette Ty; Comfortable across all areas; Less draught
17 Cooling only Heat pump Horizontal Flow 0 ° 0 ° Settable to 5 different levels between 0 ° and 35 ° Settable to 5 different levels between 0 ° and 60 ° Settable to 5 different levels between 25 ° and 60 ° Auto-swing between 0 ° and 35 ° Auto-swing between 0 ° and 60 ° Auto-swing between 25 ° and 6...
Page 19 - Two selectable temperature sensors; Mould-resistant treatment for filter; Filter sign; ype
18 Spiral hub cover At low fan speeds, the 2.5 kW model produces sound of only 24.5 dB (A), and even the 6.0 kW model as low as 32 dB (A). This is due to a new spiral hub cover that reduces internal airflow resistance. FFQ25 29.5/ 24.5 dB(A) FFQ35 32/ 25 dB(A) FFQ50 36/ 27 dB(A) FFQ60 41/ 32 dB(A) (...
Page 20 - Functions
19 Selects fan speed andIndoor Unit Quiet Operation FTK(X)S20/25/35 FTK(X)S50/60/71 Outdoor Unit Quiet Operation Intelligent Eye Cancels On/Off Timer 24-Hour On Timer 24-Hour Off Timerand Night Set Mode Sets timer Sets clock On/Off Switch Inverter Powerful Operation Sets room temperature 24-Hour On ...
Page 21 - Comfortable Airflow
20 Functions Outdoor unit Indoor unit Wall-mounted type FTK(X)S20-35 CDK(X)S/FDXS FTK(X)S50-71 Floor-standing type Floor/ceiling-suspended dual type FVXS FLXS Duct-connected type Power-Airflow Dual Flaps Comfortable Airflow Wide-Angle Louvres 3-D Airflow Comfort Control Indoor Unit Quiet Operation O...
Page 22 - Power-Airflow Dual Flaps; Econo Mode
21 See page 8 Comfortable Airflow Comfort Control Lifestyle Convenience The microprocessor automatically controls fan speed to adjust the room temperature to the set temperature. This function automatically reduces the level of humidity while maintaining the preset room temperature. This function au...
Page 23 - Night Set Mode; Flexibility; Anticorrosion Treatment of Outdoor Heat Exchanger Fins; Worry Free; Cooling/Heating Mode Lock; Comfort Control; Automatic Defrosting
22 Cleanliness Timers Worry Free Others This timer can be preset to start and stop at any time within a 24-hour period. The air conditioner is started/ stopped simply by pressing the On/Off timer button on the wireless remote controller. Pressing the Off timer button automatically selects the Night ...
Page 24 - Specifications
23 Specifications Outdoor unit Indoor unit Wall-mounted type Model name Power supplyFront panel colour Airflow rate (H) Sound level(H/L/SL) Sound powerlevel (H) Fan speedTemperature controlDimensions (H x W x D)Machine weight Piping connections Heat insulation CoolingHeatingCoolingHeating Liquid (fl...
Page 27 - Control system; Options
26 Cooling only use Options Control system Indoor unit Outdoor unit No. 12 Item Air direction adjustment grilleDrain plug 3MXS52E 3MKS58E 3MXS68E 3MKS75E 4MXS80E 4MKS90E No. 1 2 3 4 56789 101112 Wired remote controller* 1 Wired remote controller cord 5-room centralised controller* 2 Wiring adaptor f...
Page 28 - Capacity tables
27 Capacity tables A room B room C room D room 3MKS58EVMA 3MKS75EVMA Combinations of indoor units Outdoor unit Total capacity (kW) Rated (Min. _ Max.) Total power consumption (W) Rated (Min. _ Max.) Total current (A) Rated (Min. _ Max.) Capacity of each indoor unit (kW) Cooling only 240 V, 50 Hz 202...
Page 32 - Heating
31 Capacity tables 3MXS68EVMA Cooling capacity 4MXS80EVMA Cooling capacity A room B room C room D room Combinations of indoor units Outdoor unit Total capacity (kW) Rated (Min. _ Max.) Total power consumption (W) Rated (Min. _ Max.) Total current (A) Rated (Min. _ Max.) Capacity of each indoor unit ...
Page 36 - Cautions on product corrosion
All rights reserved Printed in Japan 09/09/040 DN c Dealer Head Office: Umeda Center Bldg., 2-4-12, Nakazaki-Nishi, Kita-ku, Osaka, 530-8323 JapanTokyo Office: JR Shinagawa East Bldg., 2-18-1, Konan, Minato-ku, Tokyo, 108-0075 Japan http://www.daikin.com/global_ac/ 1. Air conditioners should not be ...