Page 2 - Air Conditioners; Technical Data
BSVQ100-250P8 E E D E N 1 1 - 2 0 0 Air Conditioners I n d i v i d u a l b r a n c h s e l e c t o r f o r V R V ® h e a t r e c o v e r y ( I n d i v i d u a l B S b o x ) Technical Data
Page 3 - TABLE OF CONTENTS
• Accessories • Individual branch selector for VRV ® heat recovery 1 • Individual branch selector for VRV ® heat recovery • BSVQ-P8 TABLE OF CONTENTS BSVQ-P8 1 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Technical Spe...
Page 4 - Specifications; -1 Technical Specifications
• Individual branch selector for VRV ® heat recovery • BSVQ-P8 • Accessories • Individual branch selector for VRV ® heat recovery 2 1 Specifications Ou td oo r un i Ac ce ss or ie s BS VQ -P 8 I n d i v i d u a l Standard Accessories : Insulation pipe cover;Standard Accessories : Attached piping;Sta...
Page 5 - Safety device settings
• Accessories • Individual branch selector for VRV ® heat recovery 3 • Individual branch selector for VRV ® heat recovery • BSVQ-P8 2 Safety device settings 3 Options BSVQ-P8 4D057956B Model Safety devices PC board fuse BSVQ100PV1 250V 3.15A BSVQ160PV1 250V 3.15A BSVQ250PV1 250V 3.15A BSVQ36PVJU 250...
Page 6 - Dimensional drawing & centre of gravity; - 1 Dimensional drawing
• Individual branch selector for VRV ® heat recovery • BSVQ-P8 • Accessories • Individual branch selector for VRV ® heat recovery 4 4 Dimensional drawing & centre of gravity 4 - 1 Dimensional drawing BSVQ100PV1 3D056011 N OTES 1 Electric box can also be fixed on the other side of the unit. 2 Be ...
Page 8 - - 2 Centre of gravity
• Individual branch selector for VRV ® heat recovery • BSVQ-P8 • Accessories • Individual branch selector for VRV ® heat recovery 6 4 Dimensional drawing & centre of gravity 4 - 2 Centre of gravity BSVQ100,160PV1 3D058131 In case of the electrical box on the other side of the unit In case of the...
Page 9 - Piping diagram
• Accessories • Individual branch selector for VRV ® heat recovery 7 • Individual branch selector for VRV ® heat recovery • BSVQ-P8 5 Piping diagram BSVQ-P8 4D057985B Double pipe heat exchanger Filter Electric Expansion Valve (EVL) Filter Filter Liquid pipe connection port Electric Expansion Valve (...
Page 10 - Wiring diagram
• Individual branch selector for VRV ® heat recovery • BSVQ-P8 • Accessories • Individual branch selector for VRV ® heat recovery 8 6 Wiring diagram 6 - 1 Wiring diagram BSVQ-P8B 3TW31796-1 NOTES 1 This wiring diagram applies to the BS unit only. 2 When using the COOL/HEAT selector (optional accesso...
Page 11 - Sound data; - 1 Sound pressure spectrum
• Accessories • Individual branch selector for VRV ® heat recovery 9 • Individual branch selector for VRV ® heat recovery • BSVQ-P8 7 Sound data 7 - 1 Sound pressure spectrum 4D058945 NOTE 1 Over All (dB):(B, G, N is already rectified) 2 Operating conditions:• Power source: 220-240V 50Hz • Standard ...