Page 2 - The is now four times better.; uieter; Все каталоги и инструкции здесь:
2 1 Aero fitting grille Aero spiral fan DC fan motor structure These new features achieve a low noise fan with a large airflow, and realize a compact casing together with the compressor linking technology. New shape promotes a spiral discharge airflow, resulting in reduced pressure loss. Bending of ...
Page 3 - Wide range of indoor units; Highest COP; exactly to customer needs.; Indoor units; Top-class Energy Savings
Page 25 Page 26 Page 27 Page 28 Page 29 Page 30 Page 31 Page 32 Page 33 Page 34 4 3 Wide range Energy saving RXYQ34MY1BRXYQ36MY1B REYQ34MY1BREYQ36MY1B RXYQ38MY1BRXYQ40MY1BRXYQ42MY1B REYQ38MY1BREYQ40MY1BREYQ42MY1B RXYQ44MY1BRXYQ46MY1BRXYQ48MY1B REYQ44MY1BREYQ46MY1BREYQ48MY1B RXYQ5MY1B RXYQ8MY1B RXYQ1...
Page 4 - RSXYP; Current model
6 5 Flexible design Easy installation 50m Height difference 40 m First branch –Indoor unit 15m Level difference between indoor units. RSXYP RSXYP24KJ x 2 RXYQ48M Current model Transportation by Lift All units can be transported by lift. This makes installation dramatically easy, and effectively redu...
Page 5 - Peak in the outdoor temperature; Operation sound dB; with low operating sound level at night.; Automatic mode
8 7 Quiet operation Environmental friendly High reliability If one compressor malfunctions... Emergency operation occurs. Emergency operation occurs. If one outdoor unit malfunctions... Can be easily started by remote control of the indoor unit. Note: • This function is available in setting at site....
Page 7 - in every stage of operation.
12 11 Indoor Unit Addition Meeting room OA room Office Reception room Stock room Meeting room OA room Office Reception room Room Layout Change Because each room is controlled individually, only those rooms requiring air conditioning are cooled or heated. In addition, thanks to inverter technology, t...
Page 8 - Long Piping Design; Offers a wide selection of models
14 13 Ventilation Interlocked Control LCD remote controller for indoor unit Air conditioning This value is based on the case where the outdoor unit is located above the indoor unit.If the outdoor unit is located underneath the indoor unit the level difference is a maximum of 40m. The maximum actual ...
Page 9 - Conventional
16 15 Twin cable multiplex transmission system Power supply REFNET Header REFNET Joint for REFNET Joint ATTACHED INSULATORS for REFNET Header Outdoor unit Indoor unit Central remote controller Conventional Outdoor unit Central remote controller Indoor unit Super wiring system Note: Refer to engineer...
Page 11 - Wired remote controller; Wide variation of remote controllers for indoor units; Individual Control Systems
20 19 Outdoor unit Indoor unit Forced OFF input Remote controller Remote controller Remote controller Remote controller Remote controller Remote controller Remote controller Remote controller HRV The indoor unit can be connected by the two remote controller, for example one in the room and the other...
Page 12 - Central remote controller; Centralized Control Systems
22 21 Note : 1. Installation box for adaptor must be procured on site. Central remote controller (Optional) No. of unit Details Indoor unit Central remote controller Outdoor unit Associated with adaptor PC board Maximum 128 units (*1) Central remote controller (Max. 2 units) Unified ON/OFF controlle...
Page 13 - Advanced control systems; and; INTERNET
24 23 AIRNET SERVICE SYSTEM(Optional) Up to 3 kWh meters (with pulse output/locally procured ) Security Fire alarm PCMCIA Card For power proportional distribution Display or print outpower distribution( User PC ) Slot loading HRV VRV System (Optional ) Maximum of 64 groups Via internet Compact but p...
Page 14 - Low operating sound; Capacity range
Ceiling mounted cassette(double-flow) type FXCQ20M / FXCQ25M / FXCQ32MFXCQ40M / FXCQ50M / FXCQ63MFXCQ80M / FXCQ125M Thin, lightweight, and easy to install in narrow ceiling space 600mm Class 20 32/27 25/32 34/28 63 37/32 40/50 34/29 80 39/34 125 44/38 34/29 36/30 39/34 37/32 41/36 46/40 (dB(A)) 350m...
Page 15 - Because of the light weight, suspension is easy.; Single branch – 8 patterns; with a horizontal blow capability; Auto swing
New Super Cassette type is compact, quiet and easy to install. 750mm Regardless of their difference in capacity, all indoor units feature the same panel size and design, in consideration of harmonized interior Because of the light weight, suspension is easy. Low operating sound Installing the fresh ...
Page 16 - Slim design for flexible installation; Highly Flexible for Various Application; Installation examples
Slim design for flexible installation 3 32˚C 30˚C 28˚C 26˚C 24˚C 22˚C 20˚C 2 1 0 1 2 3 4 5 6 (m) (m) 500mm Panel spacer 20mm Min.195mm Main body Air discharge grille (option) Set for front discharge using a suspended ceiling. Downward discharge is shut off and air is blown straight out (front discha...
Page 17 - Ceiling suspended type; Simplified Static Pressure Control; High static pressure allows flexible duct design.; Slim body with quieter and wider air flow; Easy to clean flat design
Ceiling mounted duct type FXMQ40M / FXMQ50M / FXMQ63MFXMQ80M / FXMQ100M / FXMQ125M Ceiling suspended type FXHQ32M / FXHQ63M / FXHQ100M FXMQ200M / FXMQ250M Built-in Drain Pump (optional) Housing the drain pump inside the unit has reduced the space required for installation. Simplified Static Pressure...
Page 18 - Wall mounted type; Sophisticated design and compact casing; écor; Flexible installation.; Perfect unit for perimeter zone air conditioning.; Perfect unit to be concealed in the skirting-wall of perimeter.; Floor standing type
Wall mounted type FXAQ20M / FXAQ25M / FXAQ32MFXAQ40M / FXAQ50M / FXAQ63M Sophisticated design and compact casing harmonized in any interior d écor Drain pan and air filter can be kept clean by mildew-proof polystyrene. Compact and stylish design that does not detract from the decor of the room. Drai...
Page 19 - Series; Series Line Up
RXYQ34MY1BRXYQ36MY1B RXYQ38MY1BRXYQ40MY1BRXYQ42MY1B RXYQ44MY1BRXYQ46MY1BRXYQ48MY1B RXYQ5MY1B RXYQ8MY1B RXYQ10MY1B RXYQ12MY1BRXYQ14MY1BRXYQ16MY1B RXYQ18MY1BRXYQ20MY1B RXYQ22MY1BRXYQ24MY1BRXYQ26MY1B 34, 36 HP 38, 40, 42 HP 44, 46, 48 HP 5 HP 8, 10 HP 12, 14, 16 HP 18, 20 HP 22, 24, 26 HP RXYQ28MY1BRXY...
Page 20 - Ceiling Mounted Cassette Type; MODEL; Heat Recovery Type
FXCQ20MVE FXCQ25MVE FXCQ32MVE FXCQ40MVE FXCQ50MVE FXCQ63MVE FXCQ80MVE FXCQ125MVE 2.3 7,900 2,000 2.5 8,500 Galvanized steel plate 2,200 7/5 247/177 32/27 305 X 775 X 600 26.0 6.4 12.7 VP25 (External Dia, 32/Internal Dia, 25) BYBC32G-W1 White 53 X 1,030 X 680 8.0 2.9 9,900 2,500 3.2 10,900 2,800 9/6....
Page 21 - Ceiling Mounted Cassette Corner Type; 00 Multi Flow Ceiling Mounted Cassette Type; Ceiling Mounted Duct Type
220V MODEL 50Hz FXKQ25MVE kW (*1) 2.9 9,900 2,500 3.2 10,900 Galvanized steel plate 2,800 11/9 Btu/h (*1) kcal/h (*1) Heating capacity kW Btu/h 388/318 FXKQ32MVE 3.7 12,500 3,150 4.0 13,600 3,400 11/9 388/318 FXKQ40MVE 4.7 15,900 4,000 5.0 17,000 4,300 13/10 459/353 FXKQ63MVE 7.3 (*2) 2.8 3.6 4.5 7....
Page 22 - Ceiling Suspended Type; Floor Standing Type/Concealed Floor Standing Type; Wall Mounted Type
Note : Specifications are based on the following conditions ; • Cooling : (*1) Indoor temp. of 27 ° CDB, 19.5 ° CWB, and outdoor temp. of 35.0 ° CDB. (*2) Indoor temp. of 27 ° CDB, 19.0 ° CWB, and outdoor temp. of 35.0 ° CDB. • Heating : Indoor temp. of 20 ° CDB, and outdoor temp. of 7 ° CDB, 6 ° CW...
Page 24 - Ceiling mounted super cassette type (Multi flow type); 00 x 600 multi flow ceiling mounted cassette type
Total capacity of connectable indoor units Liquid mm Suction gas mm Pipingconnections Liquid mm Gas mm Discharge gas mm 100 or less Casing 185 X 310 X 280 Galvanized steel plate Power supply V1: 1 phase, 220-240V, 50Hz Dimensions (H X W X D) 9.5 (Flare) 15.9 (Flare) 9.5 (Flare) 15.9 (Flare) 12.7 (Fl...
Page 25 - For BS Units; Ceiling mounted built-in type; Ceiling mounted duct type
KPF26B280 X 2 KPF26B450 KPF26B450 X 2 Heat Pump Type No. Name of Options 1 Cool/Heat Selector KRC19-26A 1-1 Fixing box 2 REFNET header 3 REFNET joint 4 Kit of air discharge duct KHRP26M22H (Max. 4branch)KHRP26M33H (Max. 8branch) KHRP26M22H (Max. 4branch),KHRP26M33H (Max. 8branch) KHRP26M72H (Max. 8b...
Page 26 - Operation control system optional accessories; Various PC boards; Building management system
Operation control system optional accessories Note: 1. Installation box is necessary for each adaptor marked . 2. Up to 2 adaptors can be fixed for each installation box. No. 3 4 FXCQ-M FXFQ-M FXZQ-M FXKQ-M FXSQ-M FXAQ-M FXLQ-M FXNQ-M Remote controller Wireless H/P Wired C/O Simplified remote contro...
Page 28 - Heat Reclaim Ventilation; Models; Air Conditioning Load
Heat Reclaim Ventilation Note: 1. 2.3. 4.5. Sound level is measured at 1.5m below the center of the body. Air flow rate can be changed over to Low mode or High mode.Sound level is measured in an anechoic chamber.Sound level generally become greater than this value depending on the operating conditio...
Page 29 - Precautions; Refrigerant Piping Materials; R410A System/ Precautions on Installation
Precautions R410A applies higher pressure than R22 and uses refrigeration oil different from R22. Therefore, piping works and tools are also different from those for R22 refrigerants. Branch pipe and dividing pipe for R410A are provided specially for REFNET piping. Since these new parts are not inte...