Page 2 - water as a heat source. In this unique system, water is piped from a; What are its advantages?; asy installation; Cooling tower; esign flexibility; What is water cooled VRV II?; Cutting-edge technologies; Water piping; To Indoor units
1 2 A water cooled intelligent individual air conditioning system suitable for tall multistoried buildings. Water cooled VRV II is an individual air conditioning system that utilises water as a heat source. In this unique system, water is piped from a cooling tower or boiler to the VRV-WII (which is...
Page 3 - f e a t u r e s; Design flexibility; Long refrigerant piping length
Because the system is water cooled, the outdoor air temperature does not affect capacity. Furthermore, water cooling means no defrost operation is required, so rapid starting assures quick and comfortable heating even in cold environments. Cold climate capability 3 4 Enhanced design flexibility Indo...
Page 4 - Energy saving; Heat recovery; Simultaneous heating and cooling operation; Stage 1; Easy installation; Compact and lightweight; Stacked configuration is possible.; mm; or higher; or higher; IN
5 6 Energy saving f e a t u r e s Heat recovery In mainly cooling, partly heating mode, the system recycles heat exhausted from the cooling operation to use for heating. In mainly heating, partly cooling mode, the system uses cooled post-heating operation refrigerant for cooling. Efficiency improves...
Page 5 - Outside unit lineup; 0–130% of the rated capacity of the VRV-WII; A lineup of 10 to 30 HP models meets wide-ranging office space; Combination table for VRV-WII; Series; Series Lineup; Heat pump type; Centralised interlocking function; Interlocking; Control wiring; By using one external control; Enhanced usability; Easily responds to simultaneous heating; Example system layouts; * Pipes are connected as in illustration.
Outside unit lineup RWEYQ10MY1 HP 10 20 30 Model RWEYQ10MY1 RWEYQ20MY1 RWEYQ30MY1 Combination RWEYQ10MY1 x 1 RWEYQ10MY1 x 2 RWEYQ10MY1 x 3 Horse powerModelNumber of connectable indoor units Number of connectable BS units Connectable capacity 10 HP RWEYQ10MY1 Up to 16Up to 16 20 HP RWEYQ20MY1 Up to 2...
Page 6 - Control systems; Wireless remote controller; Wide variation of remote controllers for indoor units; Individual Control Systems; Wired remote controller; Adds new, advanced functions to those of the above wired remote
Control systems 9 10 The same operation modes and settings as with wired remote controllers are possible. • A light receiving unit for a ceiling-mounted cassette (double-flow, multi-flow) type, ceiling-suspended type and wall-mounted type is mounted into the indoor unit. The remote controller has ce...
Page 7 - A controller that offers freedom to administrators.; Special Software Is Not Required!; Simple Interlock Function; Usage example; controller simplify centralised control of the VRV system.; Lighting interlock
ACC center • Air Conditioning Network Service System Unification adaptor for computerised control [DCS302A52] Forced OFF from the fire alarm Pi Port • Connection to power consumption metre when using power proportional distribution function. (Optional) D -NET Plus Adapter DCS601A52(option) Number of...
Page 8 - Central remote controller; 4 groups (zones) of indoor units can be; Unified ON/OFF controller; 6 groups of indoor units can be operated; Schedule timer; Max.128 indoor units can be operated as; Centralised Control Systems
13 14 Note: 1. Installation box for adaptor must be procured on site. Central remote controller (Optional) 64 groups (zones) of indoor units can be controlled individually same as LCD Remote controller. Max. 64 groups (128 indoor units controllable)Max. 128 groups (128 indoor units) are controllable...
Page 9 - Advanced control systems; DMS504B51 Interface for use in L; DMS502B51 Interface for use in BACnet; INTER NET; BACnet; ON; S p e c i a l F u n c t i o n s; monitoring of VRV system functions; N e w F u n c t i o n s; N e w F e a t u r e s
15 16 Advanced control systems Ethernet Local Controller Please contact Daikin for compatibility with BMS system Security Power supply facility Fire alarm Lift Pump Lighting ...etc BMS HRV VRV System Integrated control systems that recognise the trend of open control systems Compatibility with BMS e...
Page 10 - Indoor units line up; Ceiling mounted cassette; Thin, lightweight, and easy to install in; Connection unit series indoor units
FXDQ-PVE (700 mm width type) with drain-up pump Indoor units line up 17 18 Ceiling mounted cassette (double-flow) type FXCQ20M / FXCQ25M / FXCQ32M FXCQ40M / FXCQ50M / FXCQ63M FXCQ80M / FXCQ125M Thin, lightweight, and easy to install in narrow ceiling spaces 600 mm Class 20 32/27 25/32 34/28 63 37/32...
Page 11 - There are 3 patterns in auto swing operation; Slim design for flexible installation
19 20 Super Cassette type is compact, quiet and easy to install. Regardless of their difference in capacity, all indoor units feature the same panel size and design, in consideration of harmonised interior decor. The FXFQ25M-80M are thin models (246 mm) which can be installed in narrow false ceiling...
Page 12 - Highly flexible for various application; Installation examples; Ceiling mounted; Slim design, quietness and; Only; Great for
21 22 Highly flexible for various application 250 mm Min. 350 mm Highly flexible installation is possible with a complete line-up of optional kits to satisfy various needs, such as the design concept, interior decoration and so on. The unit can be installed, if there is a space of 350 mm above ceili...
Page 13 - High static pressure allows flexible duct design; Without dra in; Without dra in; Simplified Static Pressure Control; Ceiling suspended type; Slim body with quiet and wide air flow; E a s y to c le a n fla t de s ign
23 24 Ceiling mounted duct type FXMQ40MA / FXMQ50MA FXMQ63MA / FXMQ80MA FXMQ100MA / FXMQ125MA FXMQ200MA / FXMQ250MA High static pressure allows flexible duct design Built-in Drain Pump (optional) Housing the drain pump inside the unit has reduced the space required for installation. More than 150 Pa...
Page 14 - Wall mounted type; Sophisticated design and compact casing; écor; Perfect unit for perimeter zone air conditioning.; Floor standing type
25 26 Wall mounted type FXAQ20MA / FXAQ25MA FXAQ32MA / FXAQ40MA FXAQ50MA / FXAQ63MA Sophisticated design and compact casing harmonised in any interior d écor Drain pan and air filter can be kept clean by mildew-proof polystyrene. Compact and stylish design that does not detract from the decor of the...
Page 15 - Specifications; I N D O O R U N I TS; Ceiling Mounted Cassette Type; MODEL; Ceiling suspended cassette type; This ultra-thin indoor unit achieves; Connection unit; Depending on installation site requirements or
Specifications 27 28 I N D O O R U N I TS Panel (Option) FXCQ20MVE FXCQ25MVE FXCQ32MVE FXCQ40MVE FXCQ50MVE FXCQ63MVE FXCQ80MVE FXCQ125MVE 2.3 7,800 2,000 2.5 8,500 Galvanised steel plate 2,200 7/5 247/177 32/27 305 X 775 X 600 26.0 6.4 12.7 VP25 (External Dia, 32/Internal Dia, 25) BYBC32G-W1 White (...
Page 16 - Ceiling Mounted Cassette Corner Type; Slim Ceiling Mounted Duct Type (700 mm width type); Ceiling Mounted Built-in Type
29 30 I N D O O R U N I TS I N D O O R U N I TS Ceiling Mounted Cassette Corner Type FXKQ25MAVE kW (*1) 2.9 9,900 2,500 3.2 10,900 Galvanised steel plate 2,800 11/9 Btu/h (*1) kcal/h (*1) Heating capacity kW Btu/h FXKQ32MAVE 3.7 12,600 3,200 4.0 13,600 3,400 FXKQ40MAVE 4.7 16,000 4,000 5.0 17,100 4,...
Page 17 - Ceiling Suspended Type; Ceiling Mounted Duct Type; Floor Standing Type/Concealed Floor Standing Type; Wall Mounted Type
31 32 I N D O O R U N I TS I N D O O R U N I TS MODEL FXHQ32MAVE Cooling capacity kW (*1) 3.7 12,600 3,200 4.0 13,600 White (10Y9/0.5) 3,400 FXHQ63MAVE 7.3 24,900 6,300 8.0 27,300 6,900 FXHQ100MAVE 11.6 (*2) 3.6 7.1 11.2 39,600 10,000 12.5 42,700 10,800 Btu/h (*1) kcal/h (*1) Heating capacity kW Btu...
Page 18 - Dimensions
33 34 O U TS I D E U N I TS I N D O O R U N I TS Note : Specifications are based on the following conditions ; • Cooling : (*1) Indoor temp. of 27- ° CDB, 19.5 ° CWB, and outdoor temp. of 35.0 ° CDB. (*2) Indoor temp. of 27 ° CDB, 19.0 ° CWB, and outdoor temp. of 35.0 ° CDB. • Heating : Indoor temp....
Page 19 - Ceiling mounted built-in type; Option List
35 36 Ceiling mounted built-in type FXSQ20M FXSQ25M FXSQ32M 1 BYBS32DJW1 KTBJ25K36W FXSQ40M FXSQ50M BYBS45DJW1 KTBJ25K56W FXSQ63M BYBS71DJW1 KTBJ25K80W FXSQ80M FXSQ100M BYBS125DJW1 KTBJ25K160W FXSQ125M Panel related Decoration PanelAccess panel 3 KAFJ252L36KAFJ253L36 KAFJ252L56KAFJ253L56 KAFJ252L80K...
Page 20 - B S U N I TS f o r H e a t R e co v e r y; O U TS I D E U N I TS; Strainer kit specifications
37 38 B S U N I TS f o r H e a t R e co v e r y Total capacity index of connectable indoor units Liquid mm Suction gas mm Piping connections Liquid mm Gas mm Discharge gas mm 100 or less Casing 185 X 310 X 280 Galvanised steel plate Power supply 1 phase, 220-240V, 50Hz Dimensions (H X W X D) 9.5 (Fl...
Page 21 - System configuration; C O N TR O L S Y S TE M; Building management system; Operation control system optional accessories
39 40 C O N TR O L S Y S TE M System configuration •Up to 64 groups of indoor units (128 units) can be connected, and ON/OFF, temperature setting and monitoring can be accomplished individually or simultaneously. Connectable up to 2 controllers in one system. Note 2, DCS302CA61 Central remote contro...
Page 22 - Nighttime free cooling operation; Total heat exchange ventilation; Enthalpy efficiency drastically improved by employing; Auto-ventilation Mode; Energy Conservation; The HRV Creates a High-Quality Environment; Compliant with the RoHS Directive*
Heat Rec l ai m Vent i l at i on Heat Rec l ai m Vant i l at i on Improv ed E ntha lpy E ffic ienc y H igher E x terna l S ta tic P res s ureE nha nc ed E nergy S a v ing F unc tions 1 2 41 42 Exhaust heat Exhaust heat The indoor accumulated heat is discharged at night. This reduces the air conditio...
Page 23 - Models; PC board adaptor for heater control kit (BRP4A50)
43 44 S P E C I F I C A TI O N S Note: 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. Sound level is measured at 1.5m below the centre of the body. Air flow rate can be changed over to Low mode or High mode. Sound level is measured in an anechoic chamber. Sound level generally becomes greater than this value de...