Page 2 - 5 Volvo Drive
This document was prepared and written by the Technical Documentation department at: Crestron Electronics, Inc. 15 Volvo Drive Rockleigh, NJ 07647 1-888-CRESTRON All brand names, product names and trademarks are the property of their respective owners. ©2008 Crestron Electronics, Inc.
Page 3 - Contents
Crestron DIN-AP2 DIN Rail Control Processor Contents Crestron Green Light™ DIN Rail Control Processor: DIN-AP2 1 Introduction ............................................................................................................................... 1 Features and Functions ........................
Page 5 - Introduction; Features and Functions
Crestron DIN-AP2 DIN Rail Control Processor Crestron Green Light™ DIN Rail Control Processor: DIN-AP2 Introduction The DIN-AP2 is a 2-Series control processor designed for small to medium-sized lighting and automation applications. DIN rail mounting enables modular installation alongside Crestron ® ...
Page 6 - DIN Rail Installation
DIN Rail Control Processor Crestron DIN-AP2 2-Series Processor Built upon Crestron’s reliable 2-Series control engine, the DIN-AP2 is extensively programmable using Crestron’s suite of powerful development software and vast database of drivers and software modules. The DIN-AP2 works seamlessly with ...
Page 7 - Ethernet and e-Control
Crestron DIN-AP2 DIN Rail Control Processor Cresnet Power Supply is required to power the DIN-AP2 and any connected Cresnet devices. Ethernet and e-Control ® 2 Built-in 10/100 Ethernet facilitates secure high-speed network connectivity, enabling extensive capabilities for remote system maintenance a...
Page 8 - Applications; The following diagram shows a DIN-AP2 in a typical application.
DIN Rail Control Processor Crestron DIN-AP2 Applications The following diagram shows a DIN-AP2 in a typical application. DIN-AP2 in a Typical Application 4 • DIN Rail Control Processor: DIN-AP2 Operations & Installation Guide – DOC. 6662A
Page 9 - Specifications; Specifications for the DIN-AP2 are listed in the following table.; SPECIFICATION DETAILS
Crestron DIN-AP2 DIN Rail Control Processor Specifications Specifications for the DIN-AP2 are listed in the following table. DIN-AP2 Specifications SPECIFICATION DETAILS CPU 32-bit Freescale ColdFire ® Microprocessor Memory SDRAM NVRAM Flash Removable Storage 32 MB 256 KB 8 MB Up to 2 GB using MMC (...
Page 11 - Physical Description; DIN-AP2 Physical View
Crestron DIN-AP2 DIN Rail Control Processor Physical Description This section provides information on the connections, controls and indicators available on your DIN-AP2. DIN-AP2 Physical View DIN-AP2 Overall Dimensions 90 mm (3.54 in) 58 mm (2.28 in) 159 mm (6.26 in) 94.2 mm (3.71 in) 1 5 8 10 2 4 3...
Page 12 - INDICATORS; Digital Input
DIN Rail Control Processor Crestron DIN-AP2 Connectors, Controls & Indicators # CONNECTORS 1 , CONTROLS & INDICATORS DESCRIPTION 1 I/O VERSIPORTS 1-8 (1) 9-pin 3.5mm detachable terminal block comprising (8) digital input/output or analog input ports (referenced to GND) Max Wire Size: 1.5 mm ...
Page 13 - MSG LED
Crestron DIN-AP2 DIN Rail Control Processor Connectors, Controls & Indicators (Continued) # CONNECTORS 1 , CONTROLS & INDICATORS DESCRIPTION 4 MSG LED (1) Red LED, illuminates when a message is present in the message log. To view the contents of the message log, use Crestron Toolbox™. 5 NET ...
Page 14 - GND; RELAYS
DIN Rail Control Processor Crestron DIN-AP2 Connectors, Controls & Indicators (Continued) # CONNECTORS 1 , CONTROLS & INDICATORS DESCRIPTION 9 COM1 & COM 2 (2) 5-pin 3.5 mm detachable terminal blocks, bidirectional comprising (2) RS-232 ports Max Wire Size: 1.5 mm 2 (16 AWG) Up to 115.2k...
Page 15 - Green LED indicates link status; IR output up to 1.2 MHz
Crestron DIN-AP2 DIN Rail Control Processor Connectors, Controls & Indicators (Continued) # CONNECTORS 1 , CONTROLS & INDICATORS DESCRIPTION 11 LAN GREEN LED YELLOW LED PIN 8 PIN 1 (1) 8-wire RJ-45 with 2 LED indicators 10/100BaseT Ethernet port Green LED indicates link status Yellow LED ind...
Page 16 - Industry Compliance; This device complies with part 15 of the FCC rules. Operation is
DIN Rail Control Processor Crestron DIN-AP2 Industry Compliance This unit has been manufactured to comply with UL’s Standards for Safety in Canada and the United States. Formal approval is pending. As of the date of manufacture, the DIN-AP2 has been tested and found to comply with specifications for...
Page 17 - Setup; Network Wiring; Installation
Crestron DIN-AP2 DIN Rail Control Processor Setup Network Wiring When wiring the Cresnet and Ethernet network, consider the following: • Use Crestron Certified Wire. NOTE: Cresnet-HP wire cannot be used. • Use Crestron power supplies for Crestron equipment. • Provide sufficient power to the system. ...
Page 18 - Installing the DIN-AP2; DIN RAIL RELEASE; Place the top of the DIN-AP2’s rail mount over the top of the DIN
DIN Rail Control Processor Crestron DIN-AP2 The DIN-AP2 is designed for installation on a DIN rail. Refer to the following diagram when installing. Installing the DIN-AP2 DIN RAIL RELEASE DIN-AP2 TOP DIN RAIL (NOT SUPPLIED) 1. Place the top of the DIN-AP2’s rail mount over the top of the DIN rail. 2...
Page 19 - Hardware Hookup; Prior to connecting the device, turn off power at the circuit
Crestron DIN-AP2 DIN Rail Control Processor Hardware Hookup Connect the Device Make the necessary connections as called out in the illustration that follows this paragraph. Refer to “Network Wiring” on page 13 before attaching the 4-position terminal block connector. Apply power after all connection...
Page 20 - Hardware Connections for the DIN-AP2
DIN Rail Control Processor Crestron DIN-AP2 Hardware Connections for the DIN-AP2 NET: POWER FROM DIN-PWS50 OR OTHER CRESNET POWER SUPPLY. PASS-THROUGH TO OTHER CRESNET DEVICES COM 1 & COM 2: BI-DIRECTIONAL RS-232 WITH HARDWARE & SOFTWARE HANDSHAKING LAN: 10/100 BASE-T ETHERNET TO LAN IR/SERI...
Page 21 - Incorrect wiring may damage the DIN-AP2 or the
Crestron DIN-AP2 DIN Rail Control Processor Versiport Connections Depending on the application, the DIN-AP2’s Versiports can be wired multiple ways. Refer to the following diagrams when wiring a Versiport. WARNING: Incorrect wiring may damage the DIN-AP2 or the connected device. NOTE: The settings f...
Page 22 - Versiport Wiring Diagrams—Analog Input Function
DIN Rail Control Processor Crestron DIN-AP2 Versiport Wiring Diagrams—Analog Input Function I/O Setup : Analog Input Pull- up R esistor : D isabled R eading a voltage from an analog source I/O Setup : Analog Input Pull-up R esistor : Enabled R eading resistance of a potentiometer 10V DC Versiport Wi...
Page 23 - Programming Software; Have a question or comment about Crestron software?; . First-time users will need to establish a user
Crestron DIN-AP2 DIN Rail Control Processor Programming Software Have a question or comment about Crestron software? Answers to frequently asked questions (FAQs) can be viewed in the Online Help section of the Crestron website. To post a question or view questions you have submitted to Crestron’s Tr...
Page 24 - Programming with Crestron SystemBuilder; Programming is organized into six system; Views; of the lighting system,; Programming with SIMPL Windows; While SIMPL Windows can be used to program the DIN-AP2,
DIN Rail Control Processor Crestron DIN-AP2 Programming with Crestron SystemBuilder Crestron SystemBuilder is the easiest method of programming but does not offer as much flexibility as SIMPL Windows. For additional details, download SystemBuilder from the Crestron website and examine the extensive ...
Page 25 - Locating the DIN-AP2 in the Device Library
Crestron DIN-AP2 DIN Rail Control Processor Locating the DIN-AP2 in the Device Library Program Manager Program Manager is the view where programmers “program” a Crestron control system by assigning signals to symbols. The symbol can be viewed by double clicking on the icon or dragging it into Detail...
Page 26 - Uploading and Upgrading; Establishing Communication; USB Communication; COMPUTER; Model
DIN Rail Control Processor Crestron DIN-AP2 Uploading and Upgrading Crestron recommends using the latest programming software and that each device contains the latest firmware to take advantage of the most recently released features. However, before attempting to upload or upgrade it is necessary to...
Page 27 - Ethernet; Functions | Ethernet Addressing
Crestron DIN-AP2 DIN Rail Control Processor marked Ethernet however, communications must be established in order to see this information in the “System Info” window. • Display the DIN-AP2’s “System Info” window (click the icon); communications are confirmed when the device information is displayed. ...
Page 28 - Programs and Firmware; Functions | Firmware...; Program Checks; Functions
DIN Rail Control Processor Crestron DIN-AP2 Programs and Firmware Program or firmware files may be distributed from programmers to installers or from Crestron to dealers. Firmware upgrades are available from the Crestron website as new features are developed after product releases. One has the optio...
Page 29 - Problem Solving; Troubleshooting; DIN-AP2 Troubleshooting; TROUBLE; LED does
Crestron DIN-AP2 DIN Rail Control Processor Problem Solving Troubleshooting The following table provides corrective action for possible trouble situations. If further assistance is required, please contact a Crestron customer service representative. DIN-AP2 Troubleshooting TROUBLE POSSIBLE CAUSE(S) ...
Page 30 - MSG; LED
DIN Rail Control Processor Crestron DIN-AP2 DIN-AP2 Troubleshooting (Continued) TROUBLE POSSIBLE CAUSE(S) CORRECTIVE ACTION MSG LED illuminates. Hardware or software failure, hardware incompatibility with software definitions or programming error. Verify that hardware configuration matches software ...
Page 31 - Verify Cresnet wiring.; System Monitor
Crestron DIN-AP2 DIN Rail Control Processor DIN-AP2 Troubleshooting (Continued) TROUBLE POSSIBLE CAUSE(S) CORRECTIVE ACTION Device not wired correctly. Verify Cresnet wiring. Improper NET ID used. Verify that device ID matches NET ID in the program. Cresnet device does not respond. Device is not rec...
Page 32 - Monitor
DIN Rail Control Processor Crestron DIN-AP2 6. Once the DIN-AP2 is in Monitor mode, connect to the PC using a USB cable. NOTE: If at any point in the above sequence, one of the timer periods expires without the SW-R button being pressed, the unit will boot normally, first running the firmware, then ...
Page 33 - Open; Network Analysis; Check Network Wiring
Crestron DIN-AP2 DIN Rail Control Processor 12. Find and select the correct firmware file (.CUZ or .zip) and click Open . 13. In the “Firmware” window, click Send . You will see a “Confirmation” window asking if you’ve selected the right file. Click OK and you will see the “File Transfer” window. 14...
Page 34 - Cable Length Equation
DIN Rail Control Processor Crestron DIN-AP2 When calculating the length of wire for a particular Cresnet run, the wire gauge and the Cresnet power usage of each network unit to be connected must be taken into consideration. Use Crestron Certified Wire only. If Cresnet units are to be daisy-chained o...
Page 35 - Reference Documents; List of Related Reference Documents; DOCUMENT TITLE; -Series Control Systems Reference Guide; Further Inquiries; ) to ask questions about Crestron products.; Future Updates
Crestron DIN-AP2 DIN Rail Control Processor Reference Documents The latest version of all documents mentioned within the guide can be obtained from the Crestron website ( www.crestron.com/manuals ). This link will provide a list of product manuals arranged in alphabetical order by model number. List...
Page 36 - Software License Agreement
DIN Rail Control Processor Crestron DIN-AP2 Software License Agreement This License Agreement (“Agreement”) is a legal contract between you (either an individual or a single business entity) and Crestron Electronics, Inc. (“Crestron”) for software referenced in this guide, which includes computer so...
Page 38 - Return and Warranty Policies; Merchandise Returns / Repair Service
DIN Rail Control Processor Crestron DIN-AP2 Return and Warranty Policies Merchandise Returns / Repair Service 1. No merchandise may be returned for credit, exchange or service without prior authorization from CRESTRON. To obtain warranty service for CRESTRON products, contact an authorized CRESTRON ...