Cisco SCE 2000 4xGBE - Manuals
Cisco SCE 2000 4xGBE – Manual in PDF format online.
Manuals:
Manual Cisco SCE 2000 4xGBE
Summary
SCE 2000 4xGBE Installation and Configuration Guide OL-7824-02 i Preface v Audience v Organization vi Related Publications vii Document Conventions viii Obtaining Documentation ix Cisco.com ix Documentation Feedback ix Obtaining Technical Assistance ix Cisco Technical Support Website ix Submitting a...
Contents SCE 2000 4xGBE Installation and Configuration Guide ii OL-7824-02 Functionality 3-2 Number of links 3-2 Redundancy 3-2 Link Continuity 3-3 Physical Topologies 3-4 Single SCE 2000 Topologies 3-4 Two Cascaded SCE 2000s For Dual Links 3-6 Topology-Related Parameters 3-7 Installation and Mainte...
Contents SCE 2000 4xGBE Installation and Configuration Guide OL-7824-02 iii Step 1: Configuring Initial Settings 5-6 Step 2: Configuring the Hostname 5-7 Step 3: Setting the Passwords 5-7 Step 4: Configuring Time Settings 5-8 Step 5: Configuring the DNS Settings 5-10 Step 6: Configuring the RDR Form...
Contents SCE 2000 4xGBE Installation and Configuration Guide iv OL-7824-02 Rebooting the SCE Platform 7-11 Shutting Down the SCE Platform 7-12 Troubleshooting 8-1 Troubleshooting Overview 8-1 Troubleshooting Tools 8-2 Problem Solving Using a Subsystems Approach 8-9 Identifying Startup Problems 8-9 T...
SCE 2000 4xGBE Installation and Configuration Guide OL-7824-02 v This preface describes who should read the SCE 2000 4xGBE Installation and Configuration Guide , how it is organized, and its document conventions Audience This guide is for the networking or computer technician responsible for install...
Preface Organization SCE 2000 4xGBE Installation and Configuration Guide vi OL-7824-02 Organization The major sections of this guide are as follows: Chapter Title Description 1 Introduction (on page 1-1 ) This chapter provides a brief introduction to Cisco Service Control. 2 Overview ( on page 2-1 )...
Preface Related Publications SCE 2000 4xGBE Installation and Configuration Guide OL-7824-02 vii Related Publications Your SCE 2000 platform and the software running on it contain extensive features and functionality, which are documented in the following resources: • Cisco CLI software: • Cisco Serv...
Preface Document Conventions SCE 2000 4xGBE Installation and Configuration Guide viii OL-7824-02 Document Conventions Command descriptions use the following conventions: boldface font Commands and keywords are in boldface . italic font Arguments for which you supply values are in i talics . [ ] Elem...
Preface Obtaining Documentation SCE 2000 4xGBE Installation and Configuration Guide OL-7824-02 ix Obtaining Documentation Cisco documentation and additional literature are available on Cisco.com http://www.cisco.com . Cisco also provides several ways to obtain technical assistance and other technica...
Preface Obtaining Additional Publications and Information SCE 2000 4xGBE Installation and Configuration Guide x OL-7824-02 Submitting a Service Request Using the online TAC Service Request Tool ( http://www.cisco.com/techsupport/servicerequest ) is the fastest way to open S3 and S4 service requests....
Chapter 1 Introduction SCE Platform Management Interfaces SCE 2000 4xGBE Installation and Configuration Guide 1-2 OL-7824-02 SCE Platform Management Interfaces You can manage the SCE 2000 platform through either of its management interfaces, CLI or SNMP. Both these interfaces provide management acce...
SCE 2000 4xGBE Installation and Configuration Guide OL-7824-02 2-1 This chapter provides a brief overview of the Cisco Service Control concept and an introduction to the SCE 2000 4xGBE Platform, the Service Control hardware component. This chapter contains the following sections: • Service Control a...
Chapter 2 Overview of the SCE 2000 Platform Service Control and the SCE Platform SCE 2000 4xGBE Installation and Configuration Guide 2-2 OL-7824-02 Table 2-1 SCE Platform Model Information Model number SCE 2020 4xGBE Link Type Gigabit Ethernet Number of Ports 4 Number of Links 2 Service Control Mana...
Chapter 2 Overview of the SCE 2000 Platform Front Panel SCE 2000 4xGBE Installation and Configuration Guide OL-7824-02 2-3 Front Panel The SCE 2000 Front Panel consists of ports and LEDs as shown in the following figure and tables. Figure 2-2: SE2000 Front Panel
Chapter 2 Overview of the SCE 2000 Platform Back Panel SCE 2000 4xGBE Installation and Configuration Guide 2-6 OL-7824-02 Back Panel The SCE 2000 platform back-panel contains the following components: • Two field-replaceable power supply units with ON/OFF switches • A field-replaceable fan drawer • ...
Chapter 2 Overview of the SCE 2000 Platform Checking the Shipping Container Contents SCE 2000 4xGBE Installation and Configuration Guide OL-7824-02 2-7 Checking the Shipping Container Contents Use the SCE 2000 Components List to check the contents of the SCE 2000 platform shipping container. Do not ...
Chapter 2 Overview of the SCE 2000 Platform SCE 2000 4xGBE Installation and Configuration Guide 2-8 OL-7824-02 Note We no longer ship the entire SCE 2000 documentation set automatically with each system. You must specifically order the documentation as part of the sales order. If you ordered documen...
SCE 2000 4xGBE Installation and Configuration Guide OL-7824-02 3-1 This chapter describes the possible deployment topologies of the SCE 2000 . The Cisco SCE solution offers a number of basic topology options that permit the user to tailor the SCE Platform to fit the needs of a particular installatio...
Chapter 3 Topology Topology Considerations SCE 2000 4xGBE Installation and Configuration Guide 3-2 OL-7824-02 • Number of links: The SCE 2000 may be connected to one or two GBE links. This is relevant for both bump-in-the-wire and Receive-Only topologies. • Redundancy: Must the system be designed to...
Chapter 3 Topology Topology Considerations SCE 2000 4xGBE Installation and Configuration Guide OL-7824-02 3-3 Link Continuity The bypass mechanism of the SCE 2000 allows traffic to continue to flow, if desired, even if the device itself is not functioning. Note that when the SCE 2000 is connected to...
Chapter 3 Topology Physical Topologies SCE 2000 4xGBE Installation and Configuration Guide 3-4 OL-7824-02 Single Link: Receive-only Topology In this topology, an optical splitter resides physically on the GBE link between the subscribers and the network. The traffic passes through the optical splitt...
Chapter 3 Topology Physical Topologies SCE 2000 4xGBE Installation and Configuration Guide OL-7824-02 3-5 Single Link: Inline Topology Typically, the SCE 2000 is connected in a full duplex GBE link between two devices (Router, BRAS, etc.). When the SCE 2000 is installed as a bump-in-the-wire, it phy...
Chapter 3 Topology Physical Topologies SCE 2000 4xGBE Installation and Configuration Guide 3-6 OL-7824-02 Dual Link: Receive-Only Topology In this topology, one SCE 2000 is connected in receive-only mode to two full duplex, GBE links using optical splitters. If the two links are load-shared, asymmet...
Chapter 3 Topology Physical Topologies SCE 2000 4xGBE Installation and Configuration Guide OL-7824-02 3-7 Two Cascaded SCE 2000s: Inline Topology This topology allows both control and monitoring functionality where redundancy is required and “inline” connection is used. The two SCE 2000 s are cascad...
Chapter 3 Topology Physical Topologies SCE 2000 4xGBE Installation and Configuration Guide 3-8 OL-7824-02 SCE 2000 Configuration There are four topology-related parameters: • Connection mode : Can be any one of the following, depending on the physical installation of the SCE 2000 : • Inline: single ...
Chapter 3 Topology Physical Topologies SCE 2000 4xGBE Installation and Configuration Guide OL-7824-02 3-9 Physically Connected Links Parameter If the system consists of more than one device, this parameter defines which link is connected to this SCE 2000 . Currently the system supports a maximum of ...
SCE 2000 4xGBE Installation and Configuration Guide OL-7824-02 4-1 This chapter explains how to install a SCE 2000 platform in a rack or in a general tabletop or workbench installation. Additionally, this chapter contains instructions for installing or replacing the power supply units and fan module...
Chapter 4 Installation and Maintenance Preparing to Install the SCE 2000 Platform SCE 2000 4xGBE Installation and Configuration Guide OL-7824-02 4-3 • Rack-mounting kit (optional) • A new AC-input or DC-input power supply • A new fan module Site Requirement Guidelines The environmental monitoring fu...
Chapter 4 Installation and Maintenance Installing the SCE 2000 Platform SCE 2000 4xGBE Installation and Configuration Guide 4-4 OL-7824-02 Site Requirements The following tables contain the site requirement specifications for the SCE 2000 . Table 4-2 SCE 2000 Environmental Requirements Specification...
Chapter 4 Installation and Maintenance Installing the SCE 2000 Platform SCE 2000 4xGBE Installation and Configuration Guide OL-7824-02 4-5 If you are not rack-mounting your SCE 2000 , place it on a sturdy tabletop or workbench. A rubber feet kit is included for tabletop installations. This section p...
Chapter 4 Installation and Maintenance Installing the SCE 2000 Platform SCE 2000 4xGBE Installation and Configuration Guide 4-6 OL-7824-02 Installing the SCE 2000 on a Workbench or Tabletop You can install the SCE 2000 platform on any flat surface as long as the surface is large enough for the SCE 2...
Chapter 4 Installation and Maintenance Installing the SCE 2000 Platform SCE 2000 4xGBE Installation and Configuration Guide 4-8 OL-7824-02 Attaching the Brackets to the SCE 2000 Before installing the SCE 2000 in the rack, you must first install an appropriate rack-mount bracket on each side of the f...
Chapter 4 Installation and Maintenance Installing the SCE 2000 Platform SCE 2000 4xGBE Installation and Configuration Guide OL-7824-02 4-9 Figure 4-5: Attaching the Mounting Brackets (2-post) Step 3 Repeat steps 1 and 2 on the other side of the SCE 2000 . This completes the steps for attaching the r...
Chapter 4 Installation and Maintenance Installing the SCE 2000 Platform SCE 2000 4xGBE Installation and Configuration Guide OL-7824-02 4-11 Step 4 Insert and tighten two screws to the Back posts of the rack. Figure 4-7: Attaching the Crossrails to the Rack Step 5 Repeat steps 2 through 4 on the othe...
Chapter 4 Installation and Maintenance Installing the SCE 2000 Platform SCE 2000 4xGBE Installation and Configuration Guide OL-7824-02 4-13 Step 4 While keeping the brackets flush against the posts or mounting strips, align the holes in the brackets with the holes on the rack or mounting strip. Figu...
Chapter 4 Installation and Maintenance Power Supply Overview SCE 2000 4xGBE Installation and Configuration Guide 4-16 OL-7824-02 Power Supply Overview The SCE 2000 is available in two power options: • Dual line feed AC power: SCE 2000 is shipped with two appropriate AC power supply cords. • Dual lin...
Chapter 4 Installation and Maintenance Power Supply Overview SCE 2000 4xGBE Installation and Configuration Guide OL-7824-02 4-17 The handle of the DC unit is at the top of the unit. Figure 4-13: DC Power Module LEDs The following LEDs are used to monitor the functioning of the power supply units: • ...
Chapter 4 Installation and Maintenance Removing and Replacing a Power Supply Unit SCE 2000 4xGBE Installation and Configuration Guide OL-7824-02 4-19 Note For AC-input power, we recommend powering the SCE 2000 platform from a 120 VAC, 15A receptacle U.S. (240 VAC, 10A international) at the power sou...
Chapter 4 Installation and Maintenance Removing and Replacing a Power Supply Unit SCE 2000 4xGBE Installation and Configuration Guide 4-20 OL-7824-02 Powering Down an AC-Input Power Supply To power down an AC-input power supply to the SCE 2000 platform, complete the following steps: Warning Make sur...
Chapter 4 Installation and Maintenance Removing and Replacing a Power Supply Unit SCE 2000 4xGBE Installation and Configuration Guide 4-22 OL-7824-02 Note The power supply is not fully seated until you tighten the installation screw on the faceplate. This completes the procedures for replacing a pow...
Chapter 4 Installation and Maintenance Removing and Replacing a Power Supply Unit SCE 2000 4xGBE Installation and Configuration Guide OL-7824-02 4-23 Note For AC-input power, we recommend powering the SCE 2000 platform from a 120 VAC, 15A receptacle U.S. (240 VAC, 10A international) at the power sou...
Chapter 4 Installation and Maintenance Fan Module Overview SCE 2000 4xGBE Installation and Configuration Guide OL-7824-02 4-25 This completes the steps for reconnecting the DC-input power supply to the SCE 2000 platform. Fan Module Overview The fan module provides cooling for the internal components...
Chapter 4 Installation and Maintenance Fan Module Overview SCE 2000 4xGBE Installation and Configuration Guide 4-26 OL-7824-02 ESD Warning Do not remove or install modules without using appropriate anti-static guard measures. The SCE 2000 includes an anti-static wrist strap in the accessory kit. Att...
Chapter 4 Installation and Maintenance Replacing the Battery SCE 2000 4xGBE Installation and Configuration Guide 4-28 OL-7824-02 Replacing the Battery The SCE 2000 has a lithium battery on its main circuit board. When the battery loses its charge, call Cisco Technical Support to replace the battery....
SCE 2000 4xGBE Installation and Configuration Guide OL-7824-02 5-1 This chapter explains how to connect the SCE 2000 platform to a local console and perform the initial system configuration via the setup wizard that runs automatically. Additionally, this chapter contains instructions for cabling the...
Chapter 5 Connecting the Management Interfaces and Performing Initial System Configuration Connecting the Local Console SCE 2000 4xGBE Installation and Configuration Guide 5-2 OL-7824-02 Setting Up the Local Console This section provides instructions for setting up your local terminal at your workst...
Chapter 5 Connecting the Management Interfaces and Performing Initial System Configuration Initial System Configuration SCE 2000 4xGBE Installation and Configuration Guide OL-7824-02 5-3 Step 4 Press Enter several times until the Cisco logo appears on the local terminal and the setup configuration d...
Chapter 5 Connecting the Management Interfaces and Performing Initial System Configuration Initial System Configuration SCE 2000 4xGBE Installation and Configuration Guide OL-7824-02 5-5 SNMP agent status Enable or disable SNMP management. GET community names Community strings to allow GET access an...
Chapter 5 Connecting the Management Interfaces and Performing Initial System Configuration Initial System Configuration SCE 2000 4xGBE Installation and Configuration Guide 5-6 OL-7824-02 • In certain cases, there will be two or more logically related parameters within a menu. In these situations, it...
Chapter 5 Connecting the Management Interfaces and Performing Initial System Configuration Initial System Configuration SCE 2000 4xGBE Installation and Configuration Guide OL-7824-02 5-7 E XAMPLE : The following example displays a typical configuration of the IP address (10.1.5.109), subnet mask (25...
Chapter 5 Connecting the Management Interfaces and Performing Initial System Configuration Initial System Configuration SCE 2000 4xGBE Installation and Configuration Guide 5-8 OL-7824-02 Note Passwords are case sensitive. Note The default password for all levels is “ cisco ”. To change the passwords...
Chapter 5 Connecting the Management Interfaces and Performing Initial System Configuration Initial System Configuration SCE 2000 4xGBE Installation and Configuration Guide 5-10 OL-7824-02 • To accept the displayed default value, press Enter . • To change the value, type the desired number of seconds...
Chapter 5 Connecting the Management Interfaces and Performing Initial System Configuration Initial System Configuration SCE 2000 4xGBE Installation and Configuration Guide 5-12 OL-7824-02 Step 6: Configuring the RDR Formatter Destination The SCE 2000 passes Raw Data Records (RDRs) to an external col...
Chapter 5 Connecting the Management Interfaces and Performing Initial System Configuration Initial System Configuration SCE 2000 4xGBE Installation and Configuration Guide OL-7824-02 5-13 Step 7: Configuring Access Control Lists (ACLs) The SCE 2000 can be configured with Access Control Lists (ACLs),...
Chapter 5 Connecting the Management Interfaces and Performing Initial System Configuration Initial System Configuration SCE 2000 4xGBE Installation and Configuration Guide 5-14 OL-7824-02 Order of Entries The order of the entries in the list is important. The entries in the list are tested sequentia...
Chapter 5 Connecting the Management Interfaces and Performing Initial System Configuration Initial System Configuration SCE 2000 4xGBE Installation and Configuration Guide OL-7824-02 5-17 Step 8: Configuring SNMP Managing the SCE 2000 is possible also via a Network Management System (NMS) that suppo...
Chapter 5 Connecting the Management Interfaces and Performing Initial System Configuration Initial System Configuration SCE 2000 4xGBE Installation and Configuration Guide 5-20 OL-7824-02 Step 9: Configuring the Topology-Dependent Parameters The topology configuration menu is a series of guided ques...
Chapter 5 Connecting the Management Interfaces and Performing Initial System Configuration Initial System Configuration SCE 2000 4xGBE Installation and Configuration Guide 5-24 OL-7824-02 Step 10: Completing and Saving the Configuration When you have completed the entire configuration, the system ch...
Chapter 5 Connecting the Management Interfaces and Performing Initial System Configuration Connecting the Management Interface SCE 2000 4xGBE Installation and Configuration Guide 5-26 OL-7824-02 E XAMPLE #2: Following is an example of a configuration that was applied and saved to the startup configu...
Chapter 5 Connecting the Management Interfaces and Performing Initial System Configuration Connecting the Management Interface SCE 2000 4xGBE Installation and Configuration Guide 5-28 OL-7824-02 Verifying Management Interface Connectivity If the SCE 2000 platform has been powered up, test now to ver...
SCE 2000 4xGBE Installation and Configuration Guide OL-7824-02 6-1 This chapter provides instructions for cabling the Gigabit Ethernet ports for both one and two SCE 2000 topologies, and for configuring Gigabit Ethernet (GBE) interface parameters. In a topology utilizing two SCE 2000 s (cascade), th...
Chapter 6 Cabling the Line Ports and Completing the Installation Connecting the line ports to the network SCE 2000 4xGBE Installation and Configuration Guide OL-7824-02 6-3 Single Link: Receive-only Topology In this topology, an optical splitter resides physically on the GBE link that the SCE 2000 s...
Chapter 6 Cabling the Line Ports and Completing the Installation Connecting the line ports to the network SCE 2000 4xGBE Installation and Configuration Guide OL-7824-02 6-5 Dual Link: Two SCE 2000s Topology In this topology, two SCE 2000 s are connected to two full duplex, GBE links, providing full ...
Chapter 6 Cabling the Line Ports and Completing the Installation Connecting the line ports to the network SCE 2000 4xGBE Installation and Configuration Guide OL-7824-02 6-7 Configuring the GBE Interface Parameters By default, the SCE 2000 GBE line interface ports are configured with auto-negotiation...
Chapter 6 Cabling the Line Ports and Completing the Installation Connecting the line ports to the network SCE 2000 4xGBE Installation and Configuration Guide 6-8 OL-7824-02 Connecting the GBE Line Interface Ports The following sections present the general procedure for cabling the GBE interface port...
Chapter 6 Cabling the Line Ports and Completing the Installation Connecting the line ports to the network SCE 2000 4xGBE Installation and Configuration Guide 6-10 OL-7824-02 Testing Connectivity: Examining Link LEDs and Counters If the SCE 2000 platform has been powered up, test now to verify that c...
Chapter 6 Cabling the Line Ports and Completing the Installation Connecting the line ports to the network SCE 2000 4xGBE Installation and Configuration Guide OL-7824-02 6-11 E XAMPLE : The following example displays a system response. SCE 2000 # show interface GigabitEthernet 0/1 Auto negotiation co...
Chapter 6 Cabling the Line Ports and Completing the Installation Installing a Cascaded System SCE 2000 4xGBE Installation and Configuration Guide OL-7824-02 6-13 Step 11 You can now start working with the Subscriber Manager. CLI Commands This section presents CLI commands relevant to the configurati...
Chapter 6 Cabling the Line Ports and Completing the Installation Installing a Cascaded System SCE 2000 4xGBE Installation and Configuration Guide 6-14 OL-7824-02 To configure the connection mode: Step 1 From the SCE 2000 (config if)# prompt, type connection-mode inline- cascade/receive-only-cascade ...
Chapter 6 Cabling the Line Ports and Completing the Installation Installing a Cascaded System SCE 2000 4xGBE Installation and Configuration Guide OL-7824-02 6-15 • Sniffing: allows the SCE 2000 platform to forward traffic on the specified link through the bypass mechanism while still analyzing the t...
Chapter 6 Cabling the Line Ports and Completing the Installation Loading and Activating a Service Control Application SCE 2000 4xGBE Installation and Configuration Guide 6-16 OL-7824-02 To view the current link mode: Step 1 From the SCE 2000 # prompt, type show interface linecard 0 link mode and pre...
SCE 2000 4xGBE Installation and Configuration Guide OL-7824-02 7-1 This chapter describes how to start up the SCE 2000 platform, reboot, and shutdown. It also describes how to manage configurations. This chapter contains the following sections: • Starting the SCE 2000 Platform 7-1 • Managing SCE 200...
Chapter 7 Basic SCE 2000 Platform Operations Starting the SCE 2000 Platform SCE 2000 4xGBE Installation and Configuration Guide 7-2 OL-7824-02 You are now ready to start your SCE 2000 platform. Proceed to the section Starting the System and Observing Initial Conditions (on page 7-2 ). Starting the S...
Chapter 7 Basic SCE 2000 Platform Operations Starting the SCE 2000 Platform SCE 2000 4xGBE Installation and Configuration Guide OL-7824-02 7-3 Final Tests The procedures for performing the final tests to verify that the SCE 2000 is functioning properly are explained in the following sections: • Veri...
Chapter 7 Basic SCE 2000 Platform Operations Managing SCE 2000 Configurations SCE 2000 4xGBE Installation and Configuration Guide 7-4 OL-7824-02 E XAMPLE : The following example shows the current User-File-Log device counters. SCE 2000 # show logger device user-file-log counters Logger device User-F...
Chapter 7 Basic SCE 2000 Platform Operations Managing SCE 2000 Configurations SCE 2000 4xGBE Installation and Configuration Guide OL-7824-02 7-5 To view the running configuration, complete the following steps: Step 1 At the SCE 2000 # prompt, type show running-config . The system shows the running c...
Chapter 7 Basic SCE 2000 Platform Operations Managing SCE 2000 Configurations SCE 2000 4xGBE Installation and Configuration Guide OL-7824-02 7-7 To show the s ystem uptime for the SCE 2000 platform software and hardware, complete the following steps: Step 1 At the SCE 2000 # prompt, type show system...
Chapter 7 Basic SCE 2000 Platform Operations Managing SCE 2000 Configurations SCE 2000 4xGBE Installation and Configuration Guide OL-7824-02 7-9 Recovering a Previous Configuration When you save a new configuration, the system automatically backs up the old configuration in the directory tffs0:syste...
Chapter 7 Basic SCE 2000 Platform Operations Performing Complex Configurations SCE 2000 4xGBE Installation and Configuration Guide 7-10 OL-7824-02 E XAMPLE : The following example displays a saved configuration file and then restores the file to overwrite the current configuration. SCE 2000 # more t...
Chapter 7 Basic SCE 2000 Platform Operations Rebooting and Shutting Down the SCE Platform SCE 2000 4xGBE Installation and Configuration Guide OL-7824-02 7-11 Rebooting and Shutting Down the SCE Platform Rebooting the SCE Platform Rebooting the SCE 2000 platform is required after installing a new fir...
Chapter 7 Basic SCE 2000 Platform Operations Rebooting and Shutting Down the SCE Platform SCE 2000 4xGBE Installation and Configuration Guide 7-12 OL-7824-02 Shutting Down the SCE Platform Shutting down the SCE 2000 platform is required before turning the power off. This helps to ensure that non-vol...
SCE 2000 4xGBE Installation and Configuration Guide OL-7824-02 8-1 Your SCE 2000 platform went through extensive testing before leaving the factory. However, if you encounter problems starting it, use the information in this chapter to help isolate the cause of the problems. The procedures in this c...
Chapter 8 Troubleshooting Troubleshooting Overview SCE 2000 4xGBE Installation and Configuration Guide 8-2 OL-7824-02 The following table shows the general troubleshooting strategy described in this chapter. Refer to this table, as necessary, to follow the steps to isolate problems to a specific sub...
Chapter 8 Troubleshooting Troubleshooting Overview SCE 2000 4xGBE Installation and Configuration Guide OL-7824-02 8-3 SCE 2000 (config)# boot system ftp://vk:[email protected]/downloads/SENum.pkg.pkg Verifying package file SENum.pkg.pkg… Package file verified OK. • Troubleshooting the management subsyst...
Chapter 8 Troubleshooting Troubleshooting Overview SCE 2000 4xGBE Installation and Configuration Guide 8-4 OL-7824-02 ip address: 10.1.6.145 subnet mask: 255.255.0.0 Configured duplex: auto AutoNegotiation is On, link is Up, actual duplex: half • show interface GigabitEthernet 0/# counters: Displays...
Chapter 8 Troubleshooting Troubleshooting Overview SCE 2000 4xGBE Installation and Configuration Guide OL-7824-02 8-5 Copying the User Log You can view the log file by copying it to an external source or to disk. This command copies both log files to the local SCE 2000 platform disk or any external ...
Chapter 8 Troubleshooting Troubleshooting Overview SCE 2000 4xGBE Installation and Configuration Guide 8-6 OL-7824-02 Clearing the User Log You can clear the contents of the user log at any time. It is recommended that a copy be made before the log is cleared. To clear the user log, complete the fol...
Chapter 8 Troubleshooting Troubleshooting Overview SCE 2000 4xGBE Installation and Configuration Guide OL-7824-02 8-7 Generating a File for Technical Support In order for technical support to be most effective, the user should provide them with the information contained in the system logs. Use the l...
Chapter 8 Troubleshooting Troubleshooting Overview SCE 2000 4xGBE Installation and Configuration Guide 8-8 OL-7824-02 SCE 2000 Operational Status The following table lists the operational states of the SCE 2000 . The Status LED on the SCE 2000 Front Panel reflects the current SCE 2000 operational st...
Chapter 8 Troubleshooting Problem Solving Using a Subsystems Approach SCE 2000 4xGBE Installation and Configuration Guide OL-7824-02 8-9 Problem Solving Using a Subsystems Approach Identifying Startup Problems Startup problems are commonly due to the source power or to a poor cable connection. When ...
SCE 2000 4xGBE Installation and Configuration Guide OL-7824-02 A-1 The SCE 2000 platform External Optical Bypass module preserves the service provider GBE links in case of complete power failure of the SCE 2000 platform, or for implementing a maintenance window. The SCE 2000 platform state-of-the-ar...
Appendix A The External Optical Bypass Module External Optical Bypass Functionality SCE 2000 4xGBE Installation and Configuration Guide A-2 OL-7824-02 External Optical Bypass Functionality The External Optical Bypass module is connected bump-in-the-wire in the GBE link. It is then connected to the S...
Appendix A The External Optical Bypass Module The External Optical Bypass Module Front Panel SCE 2000 4xGBE Installation and Configuration Guide A-4 OL-7824-02 The External Optical Bypass Module Front Panel The front panel of the External Optical bypass module contains the following components: • SU...
Appendix A The External Optical Bypass Module Installing the External Bypass Module SCE 2000 4xGBE Installation and Configuration Guide OL-7824-02 A-5 Installing the External Bypass Module Installation of the External Optical Bypass module requires two main steps, which are described in detail in th...
Appendix A The External Optical Bypass Module Installing the External Bypass Module SCE 2000 4xGBE Installation and Configuration Guide A-6 OL-7824-02 Cabling the External Optical Bypass Module The following procedure describes how to cable the External Optical Bypass module. Note the following: • A...
Appendix A The External Optical Bypass Module Installing the External Bypass Module SCE 2000 4xGBE Installation and Configuration Guide A-8 OL-7824-02 Bypass module is now active (in bypass), and is performing a loopback on these interfaces. Step 6 Connect the control cable (supplied in the kit) fro...
Appendix A The External Optical Bypass Module Specifications SCE 2000 4xGBE Installation and Configuration Guide OL-7824-02 A-9 Specifications Item Value Optical Connectors SC Switching Speed 15 ms max Operating Wavelength • Multi Mode: 850 nm • Single Mode: 1310 nm Operating Temperature -10° C to +...
SCE 2000 4xGBE Installation and Configuration Guide OL-7824-02 1 A Access control lists • 5-12 Airflow • 4-3 Application loading and testing • 6-15 Attaching a Chassis Ground Connection • 4- 12 Attaching the Brackets to the SCE 2000 • 4- 7 Attaching the Crossrail Supports to the Rack • 4-9 audience ...
Cisco Manuals
-
Cisco MGX-FRSM-HS2
Manual
-
Cisco 3545
Manual
-
Cisco Dial NMS
Manual
-
Cisco DOC-7813565=
Manual
-
Cisco 2620
Manual
-
Cisco CP7910GRF
Manual
- Cisco OL-16647-01 Manual
-
Cisco ME-C6524GS-8S
Manual
- Cisco 7970G Manual
-
Cisco OL-2056-02
Manual
-
Cisco TD 92322GB
Manual
-
Cisco OL-11524-01
Manual
-
Cisco OL-5532-02
Manual
-
Cisco VG204XM
Manual
- Cisco 7902G Manual
-
Cisco DS71-MD4
Manual
- Cisco N7KC7004S2 Manual
-
Cisco 247933900
Manual
- Cisco 124778 Manual
-
Cisco 4.5
Manual