Summary
Cisco Reader Comment Card General Information 1 Years of networking experience Years of experience with Cisco products 2 I have these network types: LAN Backbone WAN Other: 3 I have these Cisco products: Switches Routers Other: Specify model(s) 4 I perform these types of tasks: H/W Install and/or Ma...
B U S I N E S S R E P L Y M A I L F I R S T - C L A S S M A I L P E R M I T N O . 4 6 3 1 S A N J O S E C A POSTAGE WILL BE PAID BY ADDRESSEE ATTN DOCUMENT RESOURCE CONNECTIONCISCO SYSTEMS INC170 WEST TASMAN DRIVESAN JOSE CA 95134-9883 N O P O S T A G E N E C E S S A R Y I F M A I L E D I N T H E U ...
v Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 C O N T E N T S Preface xxi Audience xxi Organization xxi Related Documentation xxii MGX 8230 Edge Concentrator, Release 1.0 Related Documentation xxii Cisco WAN Manager, Relea...
Contents vi Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 DC-Powered MGX 8230 1-7 Cooling System 1-8 MGX 8230 Architecture 1-9 Cell Bus 1-10 MGX 8230 Management 1-11 Summary of MGX 8230 Cards and Modules 1-12 Introduction to...
Contents vii Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 1:N Service Module Redundancy 2-12 Bulk Distribution Mode 2-12 Module Requirements with Bulk Distribution and Redundancy 2-13 Installation Requirements for the MGX-S...
Contents viii Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 VISM Card Illustrations and LED Description 2-58 Route Processor Module (RPM) 2-61 RPM Documentation 2-61 C H A P T E R 3 Site Preparation 3-1 Parts Checklist 3-1 S...
Contents ix Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Mechanical Lift Guidelines 4-1 Installing a Stand-Alone MGX 8230 4-2 Rack Mounting an MGX 8230 4-2 Prepare for Rack Installation 4-3 Rack Positioning 4-3 Bracket Plac...
Contents x Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Configuring the OC-3 Uplink 5-10 Establishing the BPX 8600-to-BPX 8600 Series Segment 5-12 CiscoView Configuration of a Feeder 5-13 Selecting an MGX 8230 5-13 Specifyi...
Contents xi Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Eight-Port FRSM Features 6-27 Configuring Frame Relay Service 6-27 Configuring the FRSM Cards, Lines, and Ports 6-28 Adding a Frame Relay Connection 6-31 Establishing...
Contents xii Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Commands to Operate the Online Diagnostics 6-57 DS3 Loopback Test 6-58 Loopback Tests 6-58 Configure Loopback on the Entire DS3 Line 6-58 Configure Loopback on All D...
Contents xiii Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Circuit Emulation Service Module for E1 Operation A-25 Physical and Electrical Characteristics for Cards A-27 Electromagnetic Compatibility A-27 Conformance A-28 AT...
Contents xiv Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001
F I G U R E S xv Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Figure 1-1 MGX 8230 with Door Attached 1-2 Figure 1-2 MGX 8230 Slot Placement 1-5 Figure 1-3 MGX 8230 Card Cage, Front View 1-6 Figure 1-4 AC Power Supply Module...
Figures xvi Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Figure 2-24 Front Cards for the Eight-Port CESM 2-48 Figure 2-25 RJ-48 and SMB Back Cards for the MGX-CESM-8T1E1 2-49 Figure 2-26 CESM-T3/E3 Front Card 2-52 Figure 2-...
T A B L E S xvii Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Table 1 MGX 8230 Edge Concentrator Related Documentation xxii Table 2 Cisco WAN Manager Release 10 Related Documentation xxiii Table 3 Cisco WAN Switching Releas...
Tables xviii Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Table 6-10 Loopback Test for MGX-AUSM-8T1 6-55 Table 6-11 Pattern Test for MGX-AUSM-8E1 6-55 Table 6-12 Loopback Test for MGX-AUSM-8E1 6-55 Table A-1 Enclosure and E...
Tables xix Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Table A-33 Physical Characteristics and Power Consumption by Card A-27 Table A-34 Electromagnetic Compatibility and Immunity A-27 Table B-1 Trunk Cables B-1 Table B-2 ...
Tables xx Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001
xxi Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Preface This preface describes the objectives, audience, organization, and conventions of the Cisco M GX 8230 Edge Concentrator Installation and Configuration Guide. Audience...
xxii Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Preface Related Documentation Related Documentation The following Cisco publications contain additional information related to the operation of the Cisco MGX 8230 Edge Conce...
xxiii Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Preface Related Documentation Cisco WAN Manager, Release 10, Related Documentation The following table lists the documentation for the Cisco WAN Manager (CW M) network mana...
xxiv Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Preface Conventions Conventions This publication uses the following conventions to convey instructions and information. Comm and descriptions use these conventions: • Comm a...
xxv Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Preface Obtaining Documentation Notes, tips, cautions, and warnings use the following conventions and symbols: Note Means reader take note. Notes contain helpful suggestions ...
xxvi Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Preface Obtaining Technical Assistance • Registered Cisco.com users can order the Documentation CD-ROM through the online Subscription Store: http://www.cisco.com/go/subscri...
xxvii Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Preface Obtaining Technical Assistance Technical Assistance Center The Cisco TAC website is available to all customers who need technical assistance with a Cisco product or...
xxviii Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Preface Obtaining Technical Assistance
1-3 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 1 Introducing the MGX 8230 MGX 8230 System Overview The Applications of the MGX 8230 The MGX 8230 operates in the following applications: Note Refer to the Cisco docu...
1-4 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 1 Introducing the MGX 8230 MGX 8230 System Overview The supported interfaces for user-traffic are: • Frame Relay UNI on T 3, E3, HSSI, T 1, and E1 lines. • ATM UNI an...
1-5 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 1 Introducing the MGX 8230 MGX 8230 System Overview • Each service module slot can accept one single-height card or be converted to accept two double-height cards. • ...
1-6 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 1 Introducing the MGX 8230 MGX 8230 System Overview Figure 1-3 MGX 8230 Card Cage, Front View Chapter 3, “Site Preparation” and Chapter 4, “Enclosure Installation” co...
1-8 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 1 Introducing the MGX 8230 MGX 8230 System Overview Figure 1-5 MGX 8230 DC Power Entry Module Cooling System The MGX 8230 incorporates a fan tray assembly (with eight...
1-10 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 1 Introducing the MGX 8230 MGX 8230 System Overview Figure 1-7 MGX 8230 Architecture Simple Block Diagram Cell Bus The MGX 8230 cell bus (CB) provides high-speed int...
1-11 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 1 Introducing the MGX 8230 MGX 8230 System Overview Figure 1-8 Cell Bus Distribution MGX 8230 Management Firmware on each card determ ines the functions and operatio...
1-12 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 1 Introducing the MGX 8230 Summary of MGX 8230 Cards and Modules • Comm and line interface (CLI): the CL I is used for low-level control of hardware functionality an...
1-13 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 1 Introducing the MGX 8230 Summary of MGX 8230 Cards and Modules User Interface Back Cards • Processor Switch Module User Interface (PXM1-UI)The PXM1-UI is the user ...
1-16 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 1 Introducing the MGX 8230 Summary of MGX 8230 Cards and Modules Redundancy for Service Modules Service modules can have either 1:1 redundancy or 1:N redundancy. Ref...
C H A P T E R 2-1 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 2 Module and Service Descriptions This chapter includes detailed des criptions of the modules, cards and services available with the MGX 8230: • Processor Switc...
2-2 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 2 Module and Service Descriptions Processor Switching Module PXM1 Features The PXM1 ( Figure 2-1 ) is a combination ATM switching fabric, data processing, and ATM int...
2-3 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 2 Module and Service Descriptions Processor Switching Module Figure 2-1 PXM1 Front Card PXM1 User Interface Back Cards The PXM1 User Interface (PXM1-UI) back card pro...
2-4 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 2 Module and Service Descriptions Processor Switching Module • Maintenance, Control and LAN ports . PXM-UI-S3 (optional) The PXM-UI-S3 back card shown in Figure 2-3 p...
2-5 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 2 Module and Service Descriptions Processor Switching Module PXM1 Back Cards This section contains illustrations of the following PXM1 cards . • Figure 2-2 : User Int...
2-6 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 2 Module and Service Descriptions Processor Switching Module Figure 2-3 User Interface Back Card (PXM-UI-S3): Stratum 3 Clocking Alarm Output Connection Dry contact r...
2-12 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 2 Module and Service Descriptions Service Resource Module Service Resource Module A service resource module (SRM) provides three main functions for the service modul...
2-13 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 2 Module and Service Descriptions Service Resource Module Module Requirements with Bulk Distribution and Redundancy The use of bulk distribution affects the requirem...
2-15 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 2 Module and Service Descriptions ATM UNI Service Module (AUSM) ATM UNI Service Module (AUSM) The main function of the AUSM cards is to provide an ATM UNI/NNI interf...
2-16 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 2 Module and Service Descriptions ATM UNI Service Module (AUSM) Physical Layer Features All Cards • Transm itter is loop-timed to receiver or synchronized to shelf •...
2-17 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 2 Module and Service Descriptions ATM UNI Service Module (AUSM) AUSM Front Card Illustration and LED Description The AUSM/B front card oversees all major functions o...
2-18 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 2 Module and Service Descriptions ATM UNI Service Module (AUSM) Table 2-3 contains a list of eight-port LE D indicators: Back Cards for the AUSM/B The MGX-AUSM-8T1/B...
2-20 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 2 Module and Service Descriptions Frame Relay Service Modules Frame Relay Service Modules The primary function of the Frame Relay Service Modules (FRSM) is to conver...
2-21 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 2 Module and Service Descriptions Frame Relay Service Modules • Frame Relay-to-AT M network interworking (FRF.5) and Frame Relay-to-ATM service interworking (FRF.8),...
2-22 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 2 Module and Service Descriptions Frame Relay Service Modules • Standard ABR (TM 4.0 compliant). Note Note: the Foresight option is not available on MGX-FRSM-HS1/B. ...
2-23 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 2 Module and Service Descriptions Frame Relay Service Modules Frame Relay-to-ATM Network Interworking Frame Relay-to-ATM network interworking (NIW ) supports a perma...
2-24 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 2 Module and Service Descriptions Frame Relay Service Modules Frame Relay–to–ATM Direction EFCI is always set to 0. ATM–to–Frame Relay Direction If the EFCI field in...
2-25 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 2 Module and Service Descriptions Frame Relay Service Modules Cell Loss Priority In addition to frame-to-cell and DL CI-to-VPI/VCI conversion, the SIW feature maps c...
2-26 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 2 Module and Service Descriptions Frame Relay Service Modules Command and Response Mapping Comm and/Res pons e Mapping is provided in both directions. Frame Relay–to...
2-27 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 2 Module and Service Descriptions Frame Relay Service Modules Congestion Indication The FRSM maps congestion indication in both directions: Congestion Indication map...
2-28 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 2 Module and Service Descriptions Frame Relay Service Modules • Each interface configurable as a single port (FRSM-8T1) or up to 24 ports (FRSM-8T1-C) running at ful...
2-29 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 2 Module and Service Descriptions Frame Relay Service Modules Card Illustrations • Figure 2-14 is an illustration of the front card (applies to both the MGX-FRSM-8T1...
2-32 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 2 Module and Service Descriptions Frame Relay Service Modules FRSMs for T3 and E3 lines The FRSMs for T 3 and E 3 lines include the following: • MGX-FRSM-2CT3: provi...
2-33 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 2 Module and Service Descriptions Frame Relay Service Modules Card Combinations The following card combinations are supported: • MGX-FRSM-2CT3 front card with the BN...
2-38 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 2 Module and Service Descriptions Frame Relay Service Modules FRSMs for Serial Connections The FRSMs that support serial connections include the following: • MGX-FRS...
2-39 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 2 Module and Service Descriptions Frame Relay Service Modules • For the MGX-SCSI2-2HSSI back card, see Figure 2-22 on page 2-43 . • For the MGX-FRSM-HS1/B front card...
2-45 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 2 Module and Service Descriptions Frame Relay Service Modules Circuit Emulation Service Modules The m ain function of the Circuit Emulation Service Module (CESM) is ...
2-46 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 2 Module and Service Descriptions Frame Relay Service Modules • A single T1/E1 CESM card can provide standby redundancy for all active CESM cards of the same type in...
2-50 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 2 Module and Service Descriptions Frame Relay Service Modules CESM for T3 and E3 lines The MGX-CE SM-T3/E 3 supports unstructured data transfer over a single T3 or E...
2-52 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 2 Module and Service Descriptions Frame Relay Service Modules CESM T3/E3 Illustrations • The MGX-CE SM-T3/E 3 front card is shown in Figure 2-26 on page 2-52 . • BNC...
2-55 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 2 Module and Service Descriptions Frame Relay Service Modules Voice Service: The VISM The Voice Interworking Service Module (VISM) is a front and back card set desig...
2-57 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 2 Module and Service Descriptions Frame Relay Service Modules MGCP 0.1 for VoIP with Softswitch Control VISM supports Media Gateway Control Protocol (MGCP) Version 0...
2-58 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 2 Module and Service Descriptions Frame Relay Service Modules VISM Card Illustrations and LED Description Table 2-15 is a description of the VISM card L ED indicator...
2-61 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 2 Module and Service Descriptions Frame Relay Service Modules Route Processor Module (RPM) The Route Processor Module is a Cisco 7200 series router redesigned into a...
C H A P T E R 3-1 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 3 Site Preparation This section describes the steps to take and the considerations you should keep in m ind prior to installing an MGX 8230 chassis in a rack. I...
3-3 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 3 Site Preparation Regulatory Compliance and Safety Information Regulatory Compliance and Safety Information This chapter provides regulatory compliance and safety in...
3-4 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 3 Site Preparation Maintaining Safety with Electricity – Disconnect power from the system. – If possible, send another person to get medical aid. Otherwise, assess th...
3-5 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 3 Site Preparation Maintaining Safety with Electricity Product Disposal Warning Attention Ce symbole d'avertissement indique un danger. Vous vous trouvez dans une sit...
3-7 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 3 Site Preparation Maintaining Safety with Electricity Lightning Activity Warning Warning Do not work on the system or connect or disconnect cables during periods of ...
3-8 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 3 Site Preparation Maintaining Safety with Electricity Jewelry Removal Warning Warning Before working on equipment that is connected to power lines, remove jewelry (i...
3-9 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 3 Site Preparation Maintaining Safety with Electricity Power Supply Warning Warning Do not touch the power supply when the power cord is connected. For systems with a...
3-10 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 3 Site Preparation Maintaining Safety with Electricity Power Supply Disconnection Warning ¡ Advertencia ! No tocar la fuente de alimentación mientras el cable esté e...
3-11 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 3 Site Preparation Maintaining Safety with Electricity Power Disconnection Warning ¡ Advertencia ! Antes de manipular el chasis de un equipo o trabajar cerca de una ...
3-12 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 3 Site Preparation Maintaining Safety with Electricity Grounded Equipment Warning Installation Warning Warning This equipment is intended to be grounded. Ensure that...
3-13 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 3 Site Preparation Maintaining Safety with Electricity Class 1 Laser Product Warning Laser Beam Warning Advarsel Les installasjonsinstruksjonene før systemet kobles ...
3-14 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 3 Site Preparation Seismic Considerations Seismic Considerations To s ecure a Cisco-supplied cabinet, holes in the upper and lower corners accommodate 3/8" or 1/...
3-17 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 3 Site Preparation Power and Grounding Power and Grounding This section describes the requirements for electrical power and grounding the switch and the site. These ...
3-18 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 3 Site Preparation Power and Grounding For DC s upply connections, consult local or national codes for conductor sizing. Conductors must be suitable for 30 Amps. Wir...
3-19 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 3 Site Preparation Power and Grounding Figure 3-3 Mixed Grounding System Table 3-1 Ground Point Descriptions for Mixed Grounding Connection Description Z1 –48 VDC re...
3-20 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 3 Site Preparation Power and Grounding As Figure 3-3 shows, the non isolated system has a 48 VDC return that internally connects to the backplane. (T his design call...
3-21 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 3 Site Preparation Power and Grounding Using the Electrostatic Wrist Strap The MGX 8230 ships with a wrist strap for grounding the user and protecting the electronic...
3-22 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 3 Site Preparation Power and Grounding The Cisco-supplied cabinet has two pairs of grounding studs and the hardware for securing a ground conductor to the studs at t...
C H A P T E R 4-1 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 4 Enclosure Installation Chapter Summary This chapter contains instructions for installing an MGX 8230 as a stand-alone unit or in a rack. Due to the weight of ...
4-2 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 4 Enclosure Installation Installing a Stand-Alone MGX 8230 Installing a Stand-Alone MGX 8230 If the switch is a stand-alone unit, proceed directly to: • Connecting Po...
4-3 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 4 Enclosure Installation Rack Mounting an MGX 8230 Prepare for Rack Installation Review this section for inform ation on mounting and positioning the switch in a rack...
4-4 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 4 Enclosure Installation Rack Mounting an MGX 8230 Mounting Kits There are two mid-mount brackets in each rack-mounting kit. One mid-mount bracket fits on each side o...
4-6 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 4 Enclosure Installation Rack Mounting an MGX 8230 Install the MGX 8230 Using a Mechanical Lift (Recommended) The MGX 8230 is shipped with all the ordered m odules in...
4-7 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 4 Enclosure Installation Rack Mounting an MGX 8230 Install the MGX 8230 Without a Mechanical Lift (Optional) Because of the risk of damage to the modules and backplan...
4-8 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 4 Enclosure Installation Rack Mounting an MGX 8230 Step 1 Insert a the small flat head screwdriver into the lever slot and press until the latch springs open (approxi...
4-9 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 4 Enclosure Installation Rack Mounting an MGX 8230 Step 1 If applicable, attach one mid-mounting bracket to each side of the MGX 8230. Step 2 Have two people position...
4-10 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 4 Enclosure Installation Rack Mounting an MGX 8230 Re-install the front cards Step 1 Be sure the extractor is in the unlatch position. Step 2 Position the rear card ...
4-11 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 4 Enclosure Installation Rack Mounting an MGX 8230 Connecting Power for DC Systems DC power is connected to one or two DC PEMs located on the MGX 8230 chassis rear p...
4-14 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 4 Enclosure Installation Rack Mounting an MGX 8230 Step 9 Before you turn on the system power, check the supply voltage. The screws at positions 1 and 3 on the plugg...
4-15 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 4 Enclosure Installation Rack Mounting an MGX 8230 The rear panel of each AC Power Supply Module has: • An AC input connector • A special cable that connects the DC ...
4-17 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 4 Enclosure Installation Rack Mounting an MGX 8230 Figure 4-13 Rear View of MGX 8230 with One AC Power Supply Module Install the Cable Manager A fully loaded MGX 823...
4-19 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 4 Enclosure Installation Rack Mounting an MGX 8230 4. After each service module comes up, the status L EDs on each should show that it is in standby. 5. When power i...
C H A P T E R 5-1 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 5 Configuring the MGX 8230 Shelf Summary of Shelf-Level Tasks This chapter describes the shelf-level tasks used to bring up and configure the MGX 8230. These ta...
5-2 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 5 Configuring the MGX 8230 Shelf User Interface Access Ports User Interface Access Ports There are three external user-interface access ports on the PXM1 User Interfa...
5-3 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 5 Configuring the MGX 8230 Shelf MGX 8230 MGX to BPX Feeder Maintenance Port Through the maintenance port (sometimes called the modem port), you can connect either a ...
5-4 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 5 Configuring the MGX 8230 Shelf MGX 8230 MGX to BPX Feeder 3. Download MGX 8230 PXM firmware. 4. Configure a new, MGX 8230-level E thernet IP address for the MGX 823...
5-5 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 5 Configuring the MGX 8230 Shelf MGX 8230 MGX to BPX Feeder inet on backplane (b): host inet (h) : gateway inet (g) : 188.29.37.1 user (u) : ftp password (pw) (blank ...
5-6 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 5 Configuring the MGX 8230 Shelf MGX 8230 MGX to BPX Feeder Step 12 Enter the following: >setP XMPrimary “version” where version is the version number of the firmw...
5-7 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 5 Configuring the MGX 8230 Shelf MGX 8230 MGX to BPX Feeder Procedure At the MGX 8230 CL I prompt on the ASCII terminal: Step 1 Enter the default login and password p...
5-8 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 5 Configuring the MGX 8230 Shelf MGX 8230 MGX to BPX Feeder Step 8 Optionally configure a tim e zone for the node. Use cnftm zn to specify a tim e zone in the Western...
5-9 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 5 Configuring the MGX 8230 Shelf MGX 8230 MGX to BPX Feeder Note Stratum 3 clocking is available only with the PXM-UI-S3 back card. Stratum 4 clocking is available on...
5-10 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 5 Configuring the MGX 8230 Shelf MGX 8230 MGX to BPX Feeder An example comm and for downloading specific firmware for an FRSM-2CT 3 in slot 3 is: >put frsm 2ct3_1...
5-13 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 5 Configuring the MGX 8230 Shelf MGX 8230 MGX to BPX Feeder The preceding MCR and PCR formulae are predicated on a relatively small frame size of 100 octets, and eve...
5-14 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 5 Configuring the MGX 8230 Shelf MGX 8230 MGX to BPX Feeder Note If you configure MGX 8230 PXM features at the back card, select the Configure Card options by clicki...
5-15 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 5 Configuring the MGX 8230 Shelf MGX 8230 MGX to BPX Feeder Configuring Logical Interfaces for the Feeder To configure logical, broadband interfaces on the physical ...
5-16 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 5 Configuring the MGX 8230 Shelf MGX 8230 MGX to BPX Feeder Partitioning Resources on the Broadband Interface Note in this release, since PAR is the network controll...
C H A P T E R 6-1 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 6 Card and Service Configuration This chapter describes how to configure the MGX 8230 cards and the services they support. This section also contains instructio...
6-2 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 6 Card and Service Configuration Sequence of Configuration Tasks logical interface are available to any controller on a first-come, first-served basis. If necessary, ...
6-3 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 6 Card and Service Configuration Rules for Adding Connections 2. A stand-alone node supports DAX cons with one or both endpoints on the MGX 8230 PXM in addition to DA...
6-5 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 6 Card and Service Configuration The Processor Switching Module The Processor Switching Module This section describes how to activate and configure the card-level par...
6-6 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 6 Card and Service Configuration The Processor Switching Module • For external Stratum 3 clock sources, the PXM-UI-S3 back card must be used. Note See the “Making Ext...
6-8 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 6 Card and Service Configuration The Processor Switching Module • line has the range 1–4 but depends on the number of lines on the back card. For a feeder, you can ac...
6-9 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 6 Card and Service Configuration The Processor Switching Module UNI cell headers typically apply where a workstation connects through a line to a PXM1 UNI port (rathe...
6-10 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 6 Card and Service Configuration The Processor Switching Module – enable use of K1 and K2 bytes in the line-level frame for equipm ent at both ends to exchange APS-r...
6-11 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 6 Card and Service Configuration The Processor Switching Module addcon <port_num> < conn_type> <local_VP I> <local_V CI> <service> [CAC...
6-14 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 6 Card and Service Configuration ATM Universal Service Module (AUSM) ATM Universal Service Module (AUSM) The MGX-AUSM/B-8T 1 and MGX-AUSM/B-8E1 ATM Universal Service...
6-16 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 6 Card and Service Configuration ATM Universal Service Module (AUSM) Step 6 If necessary, configure resources at the port level by executing cnfportrscprtn . Use dsp...
6-17 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 6 Card and Service Configuration ATM Universal Service Module (AUSM) Configure Inverse Multiplexing This section describes the CL I command sequence for configuring ...
6-19 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 6 Card and Service Configuration ATM Universal Service Module (AUSM) cnfupcvbr has the same syntax and parameters as cnfupcabr cnfupcvbr or cnfupcabr <port.vpi.vc...
6-22 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 6 Card and Service Configuration ATM Universal Service Module (AUSM) Step 5 If necessary, change the queue depths by using cnfchanq. cnfchanq <port.vpi.vci> &l...
6-23 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 6 Card and Service Configuration Frame Service Module Features BPX 8600-to-BPX 8600 Segment For the middle segm ent, be sure to use the connection type as the local ...
6-24 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 6 Card and Service Configuration Frame Service Module Features Summary of Frame Service Module Features This section contains a sum mary of the features common to al...
6-27 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 6 Card and Service Configuration Configuring Frame Relay Service Eight-Port FRSM Features The specific features are: • Up to 1000 user-connections. • Fractional FRSM...
6-28 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 6 Card and Service Configuration Configuring Frame Relay Service Configuring the FRSM Cards, Lines, and Ports This section describes how to configure card-level para...
6-29 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 6 Card and Service Configuration Configuring Frame Relay Service The possible errors for cnfln are: • One or more parameters are invalid. • Line does not exist (has ...
6-31 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 6 Card and Service Configuration Configuring Frame Relay Service Step 6 Configure resources for the port as needed by executing cnfportrscprtn. To see the partitioni...
6-33 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 6 Card and Service Configuration Configuring Frame Relay Service • remoteConnID is the connection identifier at the remote end and can have one the following formats...
6-34 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 6 Card and Service Configuration Configuring Frame Relay Service – NodeName.SlotNo.PortNo.V PI.VCI for AT M end point. Where ControllerId can be 1 (PAR), 2 (PNNI), o...
6-35 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 6 Card and Service Configuration Configuring Frame Relay Service cnfchanstdabr <Port.DL CI/CHAN_NUM> <m cr> <pcr> <icr> < rif> <rdf&...
6-36 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 6 Card and Service Configuration Configuring Frame Relay Service Establishing the BPX 8600-to-BPX 8600 Series Segment For a three-segment connection, establish a BPX...
6-37 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 6 Card and Service Configuration Configuring Frame Relay Service • ts tcon checks the integrity of a connection. • ts tdelay m easures the round-trip delay on a conn...
6-38 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 6 Card and Service Configuration Circuit Emulation Service Module for T3 and E3 Circuit Emulation Service Module for T3 and E3 The m ain function of the Circuit Emul...
6-39 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 6 Card and Service Configuration Circuit Emulation Service Module for T3 and E3 • For E3 – Cell delay of 2.9 msec – CDVT of 2 msec in increm ents of 125 micros econd...
6-40 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 6 Card and Service Configuration Circuit Emulation Service Module for T3 and E3 Configuring the Card, Lines, and Ports This section describes how to configure param ...
6-41 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 6 Card and Service Configuration Circuit Emulation Service Module for T3 and E3 addcon . If the application requires NSAP addressing, use addchan to add the connecti...
6-42 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 6 Card and Service Configuration Eight-Port Circuit Emulation Service Modules • max_cost is a number establishing the maximum cost of the connection route. The range...
6-43 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 6 Card and Service Configuration Eight-Port Circuit Emulation Service Modules The 8-port CESM lets you configure individual physical ports for structured or unstruct...
6-45 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 6 Card and Service Configuration Eight-Port Circuit Emulation Service Modules Configuring Service on an Eight-Port CESM This section describes the steps for setting ...
6-46 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 6 Card and Service Configuration Eight-Port Circuit Emulation Service Modules • E1-signalling specifies the E1 signalling. The possible entries are – CAS, which spec...
6-49 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 6 Card and Service Configuration Service Resource Module • mcr is the minim um cell rate. The range is 1–65535 cells per second. • pct_util is the percent utilizatio...
6-50 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 6 Card and Service Configuration Service Resource Module • dsplink • dellink • addred • dspred • delred Bulk Distribution for T1 Service The MGX-SRM-3T 3/C supports ...
6-51 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 6 Card and Service Configuration Service Resource Module Redundancy Support by the MGX-SRM-3T3/C The MGX-SRM-3T 3/C can provide redundancy to service m odules with T...
6-52 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 6 Card and Service Configuration Service Resource Module Step 2 Check the redundancy status for all cards by using dspred. To remove redundancy, use delred. Configur...
6-53 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 6 Card and Service Configuration Service Resource Module Bit Error Rate Testing Through an MGX-SRM-3T3 The MGX 8230 shelf can perform a bit error rate test (BERT) on...
6-55 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 6 Card and Service Configuration Service Resource Module Pattern Test Options The pattern test options consist of the device to loop and the pattern. This section li...
6-56 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 6 Card and Service Configuration Online Diagnostics test 4. Double 1-0 pattern 5. 2 15 -1 pattern 6. 2 20 -1 pattern 7. 2 20 -1 QRSS pattern 8. 2 23 -1 pattern 9. 1 ...
6-57 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 6 Card and Service Configuration Online Diagnostics test Note Note: Certain hardware failures prevent alarms from being set. If this occurs, the log files and screen...
6-58 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 6 Card and Service Configuration DS3 Loopback Test Note Note: Do not use oldclrlock while another instance of oldiags is running on the shelf. oldsplog <log_name&...
6-59 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 6 Card and Service Configuration DS3 Loopback Test Configure Loopback on All DS1s in a DS3 Line To verify that the loopback can be configured on all the DS1s of the ...
6-60 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 6 Card and Service Configuration DS3 Loopback Test Configure Transmit FEAC Code Configure DS3 for Sending Looped or Normal Data To verify that DS3 can be configured ...
6-61 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 6 Card and Service Configuration DS3 Loopback Test Step 6 On the tester (for exam ple, HP cerjac), check that the code for dsx3SendLineCode has been received. Pass C...
6-62 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 6 Card and Service Configuration DS3 Loopback Test Step 1 Select a node with PXM-T3 back card. Step 2 Configure the receive FEAC validation criteria to be 4 out of 5...
6-63 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Chapter 6 Card and Service Configuration DS3 Loopback Test Step 1 Select a node with PXM-T3 back card. Step 2 Disable the receive FE AC validation criteria by using CLI comm...
A-1 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 A P P E N D I X A Technical Specifications This appendix provides the technical specifications relevant to the MGX 8230, its processor and s ervice modules, and the applicati...
A-2 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Appendix A Technical Specifications MGX 8230 Enclosure, Power, and Performance Specifications Table A-1 Enclosure and Electrical Characteristics Item Value Card Slot Capacity...
A-3 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Appendix A Technical Specifications MGX 8230 Processor Switching Module Specifications MGX 8230 Processor Switching Module Specifications This section contains general specif...
A-8 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Appendix A Technical Specifications AUSM/B-8T1E1 Interface Characteristics Table A-7 AUSM/B-8T1E1 Statistics and Counters Counter Type Description Per Port Num ber of cells r...
A-9 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Appendix A Technical Specifications FRSM-2CT3 Specifications FRSM-2CT3 Specifications This section provides details for the FRSM-2CT 3. Topics consist of the following: • Tra...
A-10 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Appendix A Technical Specifications FRSM-2T3E3 Specifications FRSM-2CT3 Framer The FRSM-2CT3 line framer: • Supports M13 or C-bit parity form at. • Performs required invers ...
A-11 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Appendix A Technical Specifications FRSM-2T3E3 Specifications FRSM-2T3E3 T3 Line The T 3 line characteristics appear in Table A-13 . T3 Framer Level For the framing characte...
A-12 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Appendix A Technical Specifications FRSM-HS2 Specifications FRSM-2T3E3 E3 Line For characteristics of the line on an FRSM-2T3E 3 with an E 3 back card see figure A14: E3 Fra...
A-14 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Appendix A Technical Specifications Counters and Statistics for FRSM-2CT3, FRSM-2T3E3, and FRSM-HS2 Counters and Statistics for FRSM-2CT3, FRSM-2T3E3, and FRSM-HS2 This sect...
A-15 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Appendix A Technical Specifications Counters and Statistics for FRSM-2CT3, FRSM-2T3E3, and FRSM-HS2 Number of frames received but dis carded due to • CRC error • Illegal fra...
A-16 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Appendix A Technical Specifications FRSM-HS1/B X.21 FRSM-HS1/B X.21 Interfaces • Four X.21 lines • DCE /DTE selection on a per-port basis • As DCE, clock speeds of 48 Kbps, ...
A-17 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Appendix A Technical Specifications FRSM-8T1 Specification FRSM-8T1 Specification This section provides inform ation on the T 1 operation of the FRSM-8T1E1 card set. Topics ...
A-20 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Appendix A Technical Specifications FRSM-8E1 Specification FRSM-8E1 Specification This section provides inform ation on the E 1 operation of the FRSM-8T1E1 card set. Topics ...
A-24 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Appendix A Technical Specifications Circuit Emulation Service Module for T1 Operation Circuit Emulation Service Module for T1 Operation This section contains operational det...
A-25 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Appendix A Technical Specifications Circuit Emulation Service Module for E1 Operation Circuit Emulation Service Module for E1 Operation This section contains operational det...
A-27 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Appendix A Technical Specifications Physical and Electrical Characteristics for Cards Physical and Electrical Characteristics for Cards For quick reference, Table A-33 shows...
A-28 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Appendix A Technical Specifications Conformance The levels for the mandatory CE mark immunity tests are • For IE C 61000-4-2 (ESD), the test level is 4. • For IE C 61000-4-3...
A-29 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Appendix A Technical Specifications Conformance SONET/SDH The standards and responsible organizations with which MGX 8850 SONET technology com plies are as follows : • Bell ...
A-30 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Appendix A Technical Specifications Conformance Safety The MGX 8230 enclosure m eets all applicable regulatory agency Product Safety requirements. • UL 1950, T hird E dition...
B-1 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 A P P E N D I X B Cable Specifications This appendix contains details on the MGX 8230 cabling. It includes the following sections: • T3 Trunk Cabling • Frame Relay Cabling • ...
B-2 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Appendix B Cable Specifications Frame Relay Cabling Frame Relay Cabling T1 Cabling Trunk cables connect the custom er DSX-1 cross-connect point or T 1 Channel Service Unit (C...
B-3 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Appendix B Cable Specifications Frame Relay Cabling Figure B-1 RJ-48 Connectors E1 Cabling SMB Connector E1 trunk cables connect the customer DSX-1 cross-connect point or E1 ...
B-4 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Appendix B Cable Specifications Frame Relay Cabling 12IN1-S4 V.35/X.21 Back Card The back card for the MGX-FRSM-HS1/B is the 12IN1-S4. E ach port on the back card connects th...
B-5 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Appendix B Cable Specifications Frame Relay Cabling HSSI Port Connectors The High Speed Serial Interface (HSSI) port connects through a female SCSI-II connector This connecto...
B-6 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Appendix B Cable Specifications DC Power Cabling DC Power Cabling DC Power connections are made to the DC Power Entry Modules at the rear of the MGX 8230. See Table B-11 and ...
B-7 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Appendix B Cable Specifications AC Power Cabling AC Power Cabling Either Cisco System s or the custom er can provide the AC power cord. See Table B-12 for the power cords tha...
B-8 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Appendix B Cable Specifications External Alarm Cabling External Clock Input Cabling The MGX 8230 has two external clock input connectors: a T1 RJ-45 connector and E 1 SMB con...
B-9 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 Appendix B Cable Specifications External Alarm Cabling Wire 24 AWG, shielded, 6-pair. Connector DB-15, Subminiature, male. Table B-17 Network Alarm Pin Assignments Pin No. Al...
IN-1 Cisco MGX 8230 Edge Concentrator Installation and Configuration Release 1.1.31, Part Number 78-11215-03 Rev. B0, May 2001 I N D E X Numerics 1 to 1 redundancy 1-16 A AAL5 2-20, 6-23 AC Power circuit breakers 3-17 AC Power Supply Module 4-14, 4-15 AC Power Supply module 1-6 AC power supply tray ...
Cisco Manuals
-
Cisco MGX-FRSM-HS2
Manual
-
Cisco 3545
Manual
-
Cisco Dial NMS
Manual
-
Cisco DOC-7813565=
Manual
-
Cisco 2620
Manual
-
Cisco CP7910GRF
Manual
- Cisco OL-16647-01 Manual
-
Cisco ME-C6524GS-8S
Manual
- Cisco 7970G Manual
-
Cisco OL-2056-02
Manual
-
Cisco TD 92322GB
Manual
-
Cisco OL-11524-01
Manual
-
Cisco OL-5532-02
Manual
-
Cisco VG204XM
Manual
- Cisco 7902G Manual
-
Cisco DS71-MD4
Manual
- Cisco N7KC7004S2 Manual
-
Cisco 247933900
Manual
- Cisco 124778 Manual
-
Cisco 4.5
Manual