Page 2 - Parts List
2 Cisco Connected Grid Modules for CGR 1000 Series—WiMAX Installation and Configuration Guide OL-26236-03 Parts List Figure 1 Cisco Connected Grid Modules for CGR 1000 Series—WiMAX Parts List Your WiMAX module kit contains one the following WiMAX radio modules. Parts can be ordered by referencing th...
Page 4 - Features
4 Cisco Connected Grid Modules for CGR 1000 Series—WiMAX Installation and Configuration Guide OL-26236-03 Features Features Cisco Connected Grid Modules for CGR 1000 Series—WiMAX offers the following key features: Table 2 Feature Information for WiMAX module Feature Description WiMAX technology stan...
Page 5 - Hardware Overview
5 Cisco Connected Grid Modules for CGR 1000 Series—WiMAX Installation and Configuration Guide OL-26236-03 Hardware Overview Hardware Overview The WiMAX module is designed to be installed into the CGR 1000 Series Routers ruggedized routers/concentrators designed for deployments in secondary substatio...
Page 6 - Front Panel
6 Cisco Connected Grid Modules for CGR 1000 Series—WiMAX Installation and Configuration Guide OL-26236-03 Hardware Overview • Temperature Monitoring State Machine, page 10 • Module Power States, page 10 Front Panel Figure 2 shows the front panel components of the WiMAX module. Figure 2 Front Panel o...
Page 7 - Supported Cisco WiMAX Antennas
7 Cisco Connected Grid Modules for CGR 1000 Series—WiMAX Installation and Configuration Guide OL-26236-03 Hardware Overview Supported Cisco WiMAX Antennas The antenna is connected to the QMA, panel-mount, 50-ohm connector located on the faceplate of the module. For more information about antennas, i...
Page 8 - Mechanical Specifications
8 Cisco Connected Grid Modules for CGR 1000 Series—WiMAX Installation and Configuration Guide OL-26236-03 Hardware Overview Mechanical Specifications The following are the mechanical specifications of the WiMAX module. WiMAX Interface The WiMAX module performs the following responsibilities: • Trans...
Page 9 - Module States
9 Cisco Connected Grid Modules for CGR 1000 Series—WiMAX Installation and Configuration Guide OL-26236-03 Hardware Overview The module provides two physical connectors for antennas. Module States The WiMAX module has the following states: Table 5 WiMAX Module States State Description Configured In t...
Page 10 - Radio Frequency Interface; DC Power Consumption; Module Power States
10 Cisco Connected Grid Modules for CGR 1000 Series—WiMAX Installation and Configuration Guide OL-26236-03 Hardware Overview Radio Frequency Interface The Radio Frequency (RF) interface consists of two QMA connectors on the faceplate labeled MAIN and AUX . Both antennas are mandatory; it both transm...
Page 11 - Installing and Removing the WiMAX Module; Before You Begin Installation; Installation Warning Statements
11 Cisco Connected Grid Modules for CGR 1000 Series—WiMAX Installation and Configuration Guide OL-26236-03 Installing and Removing the WiMAX Module Note The module unit defaults to the Normal state when VCC is first applied. • Disconnected mode —No power to the module. The host power source is disco...
Page 12 - Installing the WiMAX Module; Removing the WiMAX Module
12 Cisco Connected Grid Modules for CGR 1000 Series—WiMAX Installation and Configuration Guide OL-26236-03 Installing and Removing the WiMAX Module Warning To prevent airflow restriction, allow clearance around the ventilation openings to be at least: 1.75 in. (4.4 cm) Statement 1076 Installing the ...
Page 13 - Standards; Software Overview; WiMAX Overview
13 Cisco Connected Grid Modules for CGR 1000 Series—WiMAX Installation and Configuration Guide OL-26236-03 Standards Standards The following standards apply to the Cisco Connected Grid Modules for CGR 1000 Series—WiMAX. Regulatory and Compliance Information For regulatory compliance and safety infor...
Page 14 - WiMAX Link QoS; QoS Support
14 Cisco Connected Grid Modules for CGR 1000 Series—WiMAX Installation and Configuration Guide OL-26236-03 Software Overview For more on the WiMAX technology, see the following: http://www.cisco.com/web/about/ac123/ac147/archived_issues/ipj_11-2/112_wimax.html WiMAX Link QoS QoS is configured on the...
Page 16 - QoS Parameters
16 Cisco Connected Grid Modules for CGR 1000 Series—WiMAX Installation and Configuration Guide OL-26236-03 Software Overview QoS Parameters The following are configurable QoS parameters available on the base station: • Traffic priority —This parameter defines the priority assigned to specified servi...
Page 17 - Additional QoS Commands; Configuring the Module; Prerequisites
17 Cisco Connected Grid Modules for CGR 1000 Series—WiMAX Installation and Configuration Guide OL-26236-03 Configuring the Module • CS specification —This parameter defines convergence sublayer which should be used for this service flow Additional QoS Commands • (config-scan-list)# nap id nap-id pri...
Page 18 - WiMAX Interface Security; WiMAX X.509 Certificates
18 Cisco Connected Grid Modules for CGR 1000 Series—WiMAX Installation and Configuration Guide OL-26236-03 Configuring the Module • When a WiMAX module operates in a network with an Airspan base station that has a MAC profile definition based on non-authentication, some of its base station models mi...
Page 19 - EAP-TLS and EAP-TTLS Authentication Methods
19 Cisco Connected Grid Modules for CGR 1000 Series—WiMAX Installation and Configuration Guide OL-26236-03 Configuring the Module EAP-TLS and EAP-TTLS Authentication Methods To set up a username and password for the Pairwise Key Management (PKM) of a CGR 1000, the WiMAX module must be installed and ...
Page 20 - Step 1–WiMAX Scan-list Configuration; Step 2–WiMAX Interface Configuration
20 Cisco Connected Grid Modules for CGR 1000 Series—WiMAX Installation and Configuration Guide OL-26236-03 Configuring the Module Step 1–WiMAX Scan-list Configuration To create a scan-list, issue the following commands: Router# configure terminal Router(config)# wimax scan-list aaa Router(config-sca...
Page 21 - Enabling an Interface; Additional WiMAX Configuration Commands; WiMAX show Command Examples; show sprom
21 Cisco Connected Grid Modules for CGR 1000 Series—WiMAX Installation and Configuration Guide OL-26236-03 Configuring the Module Note * —The command, pkm trustpoint device device_cert_trustpoint , is not needed if 1) EAP-TLS is using the embedded Airspan certificate, or 2) if EAP-TTLS is used. Enab...
Page 22 - show controllers wimax
22 Cisco Connected Grid Modules for CGR 1000 Series—WiMAX Installation and Configuration Guide OL-26236-03 Configuring the Module fan Show fan module sprom contents mgmt-module Show mgmt module (MDS9216/MDS9216i/MDS9222i only) sprom contents module Show linecard module sprom contents powersupply Sho...
Page 23 - show interface wimax; Troubleshooting and Diagnostics
23 Cisco Connected Grid Modules for CGR 1000 Series—WiMAX Installation and Configuration Guide OL-26236-03 Troubleshooting and Diagnostics Initial RNG Backoff Start : 0 Initial RNG Backoff End : 5 Periodic RNG Backoof Start : 0 Periodic RNG Backoff End : 3 Bandwidth Request Backoof Start : 0 Bandwid...
Page 24 - WiMAX Debug Commands; Checking Signal Strength
24 Cisco Connected Grid Modules for CGR 1000 Series—WiMAX Installation and Configuration Guide OL-26236-03 Troubleshooting and Diagnostics WiMAX Debug Commands The following are the WiMAX exec debug commands: • clear interface wimax interface name statistics • debug wimax pm { all | demux | deque | ...
Page 25 - Converting Hexadecimal ESN to Decimal Notation
25 Cisco Connected Grid Modules for CGR 1000 Series—WiMAX Installation and Configuration Guide OL-26236-03 Troubleshooting and Diagnostics snmpOID : 0.0.0.0.0.0.0.0 Power Consump : -189 RMA Code : 0-0-0-0 CLEI Code : TESTING123 VID : V01 Linecard Module specific block: Block Signature : 0x6003 Block...
Page 26 - Additional References; Hardware Overview and Installation Documents; Supported Cisco Antennas and Accessories Documents
26 Cisco Connected Grid Modules for CGR 1000 Series—WiMAX Installation and Configuration Guide OL-26236-03 Additional References • 3C9854—Manufacturer’s code Step 2 Convert manufacturer’s code to decimal as shown: • Hexadecimal 0x60 equals decimal 96. • If the decimal value is two digits only, prepe...
Page 27 - Cisco System Software Commands Documents; Regulatory, Compliance, and Safety Information; Feature History
27 Cisco Connected Grid Modules for CGR 1000 Series—WiMAX Installation and Configuration Guide OL-26236-03 Feature History Cisco System Software Commands Documents • Cisco Connected Grid Device Manager User Guide • Cisco System Software http://www.cisco.com/en/US/products/ps9372/tsd_products_support...
Page 28 - Technical Assistance
28 Cisco Connected Grid Modules for CGR 1000 Series—WiMAX Installation and Configuration Guide OL-26236-03 Technical Assistance Technical Assistance The Cisco Support and Documentation website provides online resources to download documentation, software, and tools. Use these resources to install an...