Page 2 - If You Already Have a Cisco AS5800; Cisco AS5850 Universal Gateway Card Guide; System Components; Field-Replaceable Units
1-2 Cisco AS5850 Universal Gateway Hardware Installation Guide 78-10573-06 0A Chapter 1 Cisco AS5850 Product Overview If You Already Have a Cisco AS5800 If You Already Have a Cisco AS5800 If you already have a Cisco AS5800, the Cisco AS5850 should be easy to adjust to. The following major difference...
Page 3 - Note
1-3 Cisco AS5850 Universal Gateway Hardware Installation Guide 78-10573-06 0A Chapter 1 Cisco AS5850 Product Overview System Components Figure 1-1 Cisco AS5850 with 2400W AC-Input Power Shelf—Front View Note Figure 1-1 shows a system with two RSCs and a split backplane, and both sides supporting T3 ...
Page 4 - Functional Overview; “Network Management” section on page 1-8
1-4 Cisco AS5850 Universal Gateway Hardware Installation Guide 78-10573-06 0A Chapter 1 Cisco AS5850 Product Overview Functional Overview Figure 1-2 Cisco AS5850 with AC-Input Power Shelf—Rear View Functional Overview The Cisco AS5850 supports high-density dial aggregation and integrates with the Ci...
Page 5 - “Split Backplane” section on page 1-11
1-5 Cisco AS5850 Universal Gateway Hardware Installation Guide 78-10573-06 0A Chapter 1 Cisco AS5850 Product Overview Functional Overview any DS0 can be mapped to any HDLC controller or universal port. You can install multiple ingress interface cards of like types and configure the Cisco AS5850 for ...
Page 6 - For detailed system specification tables, refer to; Traffic Flow; shows inbound connection flow for the Cisco AS5850.; A typical user connection flows as follows:
1-6 Cisco AS5850 Universal Gateway Hardware Installation Guide 78-10573-06 0A Chapter 1 Cisco AS5850 Product Overview Functional Overview A dial wholesale customer can connect to a Cisco AS5850, then tunnel PPP (Point-to-Point Protocol) packet information to a retail service provider using dial Virt...
Page 7 - Power Flow
1-7 Cisco AS5850 Universal Gateway Hardware Installation Guide 78-10573-06 0A Chapter 1 Cisco AS5850 Product Overview Functional Overview Power Flow Figure 1-4 shows how power is distributed to various universal gateway field-replaceable units. Figure 1-4 Power Distribution Note VDC output of the 24...
Page 8 - Network Management
1-8 Cisco AS5850 Universal Gateway Hardware Installation Guide 78-10573-06 0A Chapter 1 Cisco AS5850 Product Overview Functional Overview Network Management The Cisco Universal Gateway Manager (Cisco UGM) configures and manages fault, performance, and security of the Cisco AS5850. Cisco UGM is a UNI...
Page 9 - shows the possible trunk card configurations for RSC:; Chassis Trunk Type; T3 only; Split Chassis
1-9 Cisco AS5850 Universal Gateway Hardware Installation Guide 78-10573-06 0A Chapter 1 Cisco AS5850 Product Overview Cisco AS5850 Chassis Cisco AS5850 Chassis The Cisco AS5850 contains 14 slots (numbered 0 through 13 on the backplane) and can support trunk cards and universal port cards in slots 0 ...
Page 10 - Clock Management; combination
1-10 Cisco AS5850 Universal Gateway Hardware Installation Guide 78-10573-06 0A Chapter 1 Cisco AS5850 Product Overview Cisco AS5850 Chassis Note Mixing CT1 or CT3 and CE1 or STM1 in the same chassis is not supported. If this configuration guideline is violated, an error message appears on the RSC an...
Page 11 - The; show chassis clocks; Split Backplane; Administration, Maintenance, and Provisioning Guide
1-11 Cisco AS5850 Universal Gateway Hardware Installation Guide 78-10573-06 0A Chapter 1 Cisco AS5850 Product Overview Cisco AS5850 Chassis condition is detected. Two clock inputs specified with identical priorities both go into the ordered list of clock sources, but the one received first by the RS...
Page 12 - OIR Events
1-12 Cisco AS5850 Universal Gateway Hardware Installation Guide 78-10573-06 0A Chapter 1 Cisco AS5850 Product Overview Cisco AS5850 Chassis Note If you need to OIR the RSC serving as the primary clock source with a split backplane configuration, you will need to switch the primary clock source to th...
Page 13 - Environmental Monitoring; Appendix A, “Cisco AS5850 Specifications.”; Gateway Card Guide; Field-Replaceable Unit
1-13 Cisco AS5850 Universal Gateway Hardware Installation Guide 78-10573-06 0A Chapter 1 Cisco AS5850 Product Overview Field-Replaceable Units In systems with two RSCs, the way the RSC uses the backplane buses will depend on the mode the system is operating in. Sometimes one RSC will control all the...
Page 14 - Feature Cards; Cooling Module; Route Switch Controller Card
1-14 Cisco AS5850 Universal Gateway Hardware Installation Guide 78-10573-06 0A Chapter 1 Cisco AS5850 Product Overview Field-Replaceable Units Feature Cards For information about the feature cards used in the Cisco AS5850, refer to the Cisco AS5850 Universal Gateway Card Guide that shipped with your...
Page 15 - Gigabyte of
1-15 Cisco AS5850 Universal Gateway Hardware Installation Guide 78-10573-06 0A Chapter 1 Cisco AS5850 Product Overview Field-Replaceable Units • Boots and reloads software images • Provides source clocks used by all feature cards and power supplies • Provides a BITS input BNC connector • Connects to...
Page 16 - LED Indicators and Alarm Buttons; and
1-16 Cisco AS5850 Universal Gateway Hardware Installation Guide 78-10573-06 0A Chapter 1 Cisco AS5850 Product Overview Field-Replaceable Units LED Indicators and Alarm Buttons The RSC front panel contains several LEDs, push buttons, LCDs, and connectors. Figure 1-7 and Figure 1-8 show the RSC front ...
Page 17 - describes the RSC front panel LEDs and LCDs.; LED Indicator; Power and Warning LEDs
1-17 Cisco AS5850 Universal Gateway Hardware Installation Guide 78-10573-06 0A Chapter 1 Cisco AS5850 Product Overview Field-Replaceable Units Figure 1-8 ERSC Front Panel Table 1-4 describes the RSC front panel LEDs and LCDs. 82530 PWR HIST ALARM MAINT MODE MAST CLK FLASH COMP A CT FLASH R OUTE SWIT...
Page 18 - Clock and Status LEDs; Button
1-18 Cisco AS5850 Universal Gateway Hardware Installation Guide 78-10573-06 0A Chapter 1 Cisco AS5850 Product Overview Field-Replaceable Units Figure 1-7 shows the RSC front panel push buttons, Table 1-5 describes push button actions, and Table 1-6 describes options for those actions. MAINT Yellow F...
Page 19 - Warning; document that accompanied this device.; Common Logic Interface; Function; Port
1-19 Cisco AS5850 Universal Gateway Hardware Installation Guide 78-10573-06 0A Chapter 1 Cisco AS5850 Product Overview Field-Replaceable Units Figure 1-7 shows the RSC front panel ports, and Table 1-7 describes the port functions. Warning To avoid electric shock, do not connect safety extra-low volt...
Page 20 - Gigabit Ethernet Egress; The RSC has dual gigabit Ethernet interfaces (See
1-20 Cisco AS5850 Universal Gateway Hardware Installation Guide 78-10573-06 0A Chapter 1 Cisco AS5850 Product Overview Field-Replaceable Units Only one common logic is active at a time, identified by the CLK LED on the RSC card front panel. The active common logic is user-selectable and is independe...
Page 22 - LED; Pin Signal
1-22 Cisco AS5850 Universal Gateway Hardware Installation Guide 78-10573-06 0A Chapter 1 Cisco AS5850 Product Overview Field-Replaceable Units Table 1-8 Egress Interface LEDs LED Color Function RX-SYNC Green GMAC. OPT-DET Green Indicates that the gigabit Ethernet port is plugged in, and auto-negotia...
Page 23 - DC-Input Power Entry Module; GBIC Product
1-23 Cisco AS5850 Universal Gateway Hardware Installation Guide 78-10573-06 0A Chapter 1 Cisco AS5850 Product Overview Field-Replaceable Units Figure 1-10 GBIC Module DC-Input Power Entry Module The Cisco AS5850 is equipped with two power-entry modules (PEMFs), which accept DC-input power either fro...
Page 24 - Pin
1-24 Cisco AS5850 Universal Gateway Hardware Installation Guide 78-10573-06 0A Chapter 1 Cisco AS5850 Product Overview Field-Replaceable Units • Voltage level and current monitoring The DC-input power supply is designed to prevent any energy hazard during operation. DC power is first routed to a cir...
Page 25 - Circuit
1-25 Cisco AS5850 Universal Gateway Hardware Installation Guide 78-10573-06 0A Chapter 1 Cisco AS5850 Product Overview Field-Replaceable Units Note Connect the alarm port only to a safety extra-low voltage (SELV) source using 22 AWG, or thicker, copper wire. SELV ratings are maximum 30 Volts AC (RMS...
Page 26 - For detailed specification tables, refer to; 400W AC-Input Power Shelf
1-26 Cisco AS5850 Universal Gateway Hardware Installation Guide 78-10573-06 0A Chapter 1 Cisco AS5850 Product Overview Field-Replaceable Units The PEMFs contain two LEDs on the front panel—POWER and MISWIRE. The POWER LED indicates that input voltage is present and the PEMF circuit breaker is on; th...
Page 28 - 400W Power Shelf LED Indicators; Power Requirements; AC-Input Power Specifications
1-28 Cisco AS5850 Universal Gateway Hardware Installation Guide 78-10573-06 0A Chapter 1 Cisco AS5850 Product Overview Power Requirements 2400W Power Shelf LED Indicators The 2400W AC-input power shelf includes three LEDs that are located on the front of each power module for the 2400W AC-input powe...
Page 29 - DC-Input Power Specifications; Online Insertion and Removal
1-29 Cisco AS5850 Universal Gateway Hardware Installation Guide 78-10573-06 0A Chapter 1 Cisco AS5850 Product Overview Online Insertion and Removal DC-Input Power Specifications The PEMFs provide –48 VDC power, which is distributed from the PEMF to the chassis backplane. No damage occurs to the PEMF...