Page 2 - Installation Instructions; DISCLAIMER
CMS490 Installation Instructions 2 DISCLAIMER Milestone AV Technologies and its affiliated corporations andsubsidiaries (collectively "Milestone"), intend to make thismanual accurate and complete. However, Milestone makes noclaim that the information contained herein covers all details,condi...
Page 3 - DIMENSIONS
Installation Instructions CMS490 3 DIMENSIONS LEGEND 34.9 1.38 22.4 0.88 88.9 3.50 0.88 34.9 1.38 88.9 3.50 DIMENSIONS: [MILLIMETERS] INCHES Tighten Fastener Apretar elemento de fijación Befestigungsteil festziehen Apertar fixador Serrare il fissaggio Bevestiging vastdraaien Serrez les fixations Loo...
Page 4 - TOOLS REQUIRED FOR INSTALLATION
CMS490 Installation Instructions 4 TOOLS REQUIRED FOR INSTALLATION PARTS 1/4" (concrete) 5/32" (wood) BAG A BAG C BAG F BAG B BAG D BAG G BAG E BAG H A (2)[Track clip - left] B (2)[Track clip - right] C (2)10-24 x 1/2" D (4)10-24 x 1/2" E (2)10-32 x 3/8" F (4) 06-32 x 1/2" G ...
Page 5 - PREPARING FOR INSTALLATION; Installation Requirements; Figure 1; Installing CMS490 Framework; Figure 2
Installation Instructions CMS490 5 PREPARING FOR INSTALLATION Installation Requirements The CMS490 has been designed to be mounted recessed intoa suspended ceiling consisting of 2’ x 2’ ceiling tiles andsecured by a WireVice system. Preparing Framework 1. Attach track clips [2 left (A), 2 right (B)]...
Page 6 - Securing CMS490 Frame to Ceiling Structure; Figure 4; Figure 5; Steel Truss Ceiling Structure
CMS490 Installation Instructions 6 Securing CMS490 Frame to Ceiling Structure 1. Examine ceiling structure (concrete, steel truss, or wood)above CMS490 frame (N) to identify four support cableanchor locations. Each location should be approximately15° outside of support holes in CMS490 frame (N). Mar...
Page 7 - Wood Ceiling Structure; Installing Cable to CMS490 Frame; Installing Electrical Box and Outlet; Figure 9
Installation Instructions CMS490 7 Wood Ceiling Structure WARNING: Anchors must be installed into wood with a minimum thickness of 1-1/2" (38.1 mm) or greater. 1. Drill a 5/32" diameter x 1-1/2" deep pilot hole at eachmarked cable anchor support location. Ensure hole is atleast 5/8" ...
Page 8 - Placing CMS490 Into Ceiling Structure
CMS490 Installation Instructions 8 Placing CMS490 Into Ceiling Structure 1. Orient CMS490 so that the electrical opening lines up withthe outlet box attachment plate (J) on the CMS490 frame.(See Figure 10) 2. Lift CMS490 (L) into place through the CMS490 frame (N).(See Figure 10) 3. Lower onto CMS49...
Page 9 - This kit must be grounded. If there is a; Grounding Instructions
Installation Instructions CMS490 9 WARNING: IMPROPER INSTALLATION CAN LEAD TO KIT FALLING CAUSING SEVERE PERSONAL INJURY ORDAMAGE TO EQUIPMENT! It is the installers responsibilityto make certain the structure to which the kit is beingmounted is capable of supporting five times the weight of thekit a...
Page 10 - The appropriate outlet being installed; Adding Components
CMS490 Installation Instructions 10 WARNING: RISK OF ELECTROCUTION ! All electrical wiring required for installation should be installed by aqualified electrician. IMPORTANT ! : The appropriate outlet being installed must be the grounding type and properly grounded inaccordance with all local codes ...
Page 12 - Europe; Asia Pacific
CMS490 Installation Instructions USA/International A 8401 Eagle Creek Parkway, Savage, MN 55378 P 800.582.6480 / 952.894.6280 F 877.894.6918 / 952.894.6918 Europe A Franklinstraat 14, 6003 DK Weert, Netherlands P +31 (0) 495 580 852 F +31 (0) 495 580 845 Asia Pacific A Office No. 1 on 12/F, Shatin G...