Page 2 - IMPORTANT WARNINGS and CAUTIONS!; CAUTION; TOOLS REQUIRED FOR INSTALLATION
Instruction Manual Plasma Display Electric Pop-Up Lift 1 IMPORTANT WARNINGS and CAUTIONS! WARNING: A WARNING alerts you to the possibility of serious injury or death if you do not follow the instructions. CAUTION: A CAUTION alerts you to the possibility of damage or destruction of equipment if you d...
Page 3 - CONTENTS; TROUBLESHOOTING
2 Instruction Manual Plasma Display Electric Pop-Up Lift CONTENTS WEIGHT, SIZE, AND VERTICAL TRAVEL SPECIFICATIONS ............................. 3 DIMENSIONAL DRAWING ............................. 4 INSPECT AND TEST THE UNIT BEFORE INSTALLING ..................................... 5 Inspect The Unit ...
Page 4 - Model
Instruction Manual Plasma Display Electric Pop-Up Lift 3 3. Determine the inside dimensions available in your furniture/ cabinet (see Table 2, “Adjustable Width ). Table 1: Weight, Size, and Vertical Travel Model Lift Capacity Outside Dimensions Max. Equipment Size HxWxD Vertical Travel PUL4228 230L...
Page 5 - DIMENSIONAL DRAWING; Front View; ADJUSTABLE
4 Instruction Manual Plasma Display Electric Pop-Up Lift DIMENSIONAL DRAWING See Table 1 on page 3 for outside adjustable width, dimension “H” and dimension “W”. Front View Side View Top View DIMENSION "H" ADJUSTABLE WIDTH 44.125 NIM - 56.125 MAX OUTSIDE 11" MAX ADJUSTMENT 4" MIN 1.4...
Page 6 - INSPECT AND TEST THE UNIT BEFORE INSTALLING; Inspect The Unit; To
Instruction Manual Plasma Display Electric Pop-Up Lift 5 INSPECT AND TEST THE UNIT BEFORE INSTALLING Inspect The Unit 1. Carefully inspect the Plasma Display Electric Pop-Up Lift (PUL) for shipping damage. If any damage is apparent, call your carrier claims agent and do not continue with the install...
Page 7 - PREPARE THE FURNITURE/CABINET AND INSTALL THE LIFT; General Guidelines; Furniture Opening Finish Piece Options
6 Instruction Manual Plasma Display Electric Pop-Up Lift PREPARE THE FURNITURE/CABINET AND INSTALL THE LIFT Because of the wide variety of possible mounting situations, Chief Manufacturing can only provide general guidelines for lift installation. Study the following information carefully, and adapt...
Page 10 - Install the PUL into the Cabinet
Instruction Manual Plasma Display Electric Pop-Up Lift 9 Install the PUL into the Cabinet 1. Adjust motor/control box unit (see Figure 9). NOTE: The motor/control box unit is factory set to the nar- rowest horizontal position. a. Loosen the six 5/16”-18X5/8” hex head bolts on the front of each half ...
Page 11 - INSTALL THE DISPLAY ON THE LIFT; Attach Brackets to the Display
10 Instruction Manual Plasma Display Electric Pop-Up Lift INSTALL THE DISPLAY ON THE LIFT Attach Brackets to the Display 1. Follow the instructions accompanying the PSB brackets designed for your display. Mount the Display 1. Remove 4 screws and slide back panel cover up and out (see Figure 11). 2. ...
Page 12 - ADJUSTMENTS; Width Adjustment
Instruction Manual Plasma Display Electric Pop-Up Lift 11 ADJUSTMENTS WARNING: Be aware during the installation that this is a motorized device, and there are pinch points for people and for electrical wiring. Width Adjustment Adjust width as follows (see Figure 14): 1. Loosen the six 5/16”-18X5/8” ...
Page 13 - THIS PAGE INTENTIONALLY BLANK
12 Instruction Manual Plasma Display Electric Pop-Up Lift THIS PAGE INTENTIONALLY BLANK
Page 14 - WIRING EXAMPLES
Instruction Manual Plasma Display Electric Pop-Up Lift 13 WIRING EXAMPLES The information on the following pages cover the most common wiring options: • Pushbutton • Extend and Retract Terminals to be Triggered By Separate Dry Contacts • Remote (RC-10) • 12 Volt out supply • 24 Volt out supply • Two...
Page 16 - Black lead
Instruction Manual Plasma Display Electric Pop-Up Lift 15 Remote (RC-10) Wire for remote (RC-10) operation as follows (see Figure 21): 1. Install a jumper wire between terminals #6 and terminal #2 (see Figure 22). 2. Connect the white wire of the RC-10 controller unit toterminal #1 (see Figure 23). ...
Page 18 - 2 Volt Out Supply
Instruction Manual Plasma Display Electric Pop-Up Lift 17 12 Volt Out Supply This internal power supply can be used to power external devices &/or to initiate specific functions (see Pushbutton operation and Figure 25). 1. Connect one lead to 12 VOLT GROUND (terminal #9). 2. Connect one lead to ...
Page 20 - Suggested Action
Instruction Manual Plasma Display Electric Pop-Up Lift 19 TROUBLESHOOTING If the lift is installed according to these instructions, it should operate trouble-free indefinitely. If you do encounter a problem, and it isn’t covered by the troubleshooting suggestions below, call the Technical Services D...
Page 21 - DESCRIPTION
20 Instruction Manual Plasma Display Electric Pop-Up Lift TERMINAL FUNCTION DEFINITIONS TERMINAL NUMBER FUNCTION DESCRIPTION WIRING OPTIONS NOTES 1 24 VOLT AC 24 volt AC output 2 24 VOLT AC COMMON 24 volt AC common This is an internal power supply forpowering external devices & RemoteControllers...
Page 22 - WIRING A MOMENTARY PUSH BUTTON
Instruction Manual Plasma Display Electric Pop-Up Lift 21 11 EXTEND Extends unit to preset travel limit. Customer within a preset maximum range may adjust travel limits. If using Latching Switch, be sure todisengage Switch prior to initiating anyother function. 12 RETRACT Retracts unit to preset tra...