Page 2 - Have questions or need assistance?; Call our Customer Care Team Toll-Free at:; AN IMPORTANT MESSAGE ABOUT TEMPERATURE:
*We are always working to improve our products. Therefore, the enclosed product may differ slightly from the image on the cover. Have questions or need assistance? Do not return this product to the store ! WE ARE HERE TO HELP! Visit our website: www.championpowerequipment.com for more info: • Produc...
Page 3 - DUAL FUEL GENERATOR; TABLE OF CONTENTS; Electric Start
76555 DUAL FUEL GENERATOR TABLE OF CONTENTS Introduction 1 Introduction 1 Portable Power Generator 1 Accessories 1 This Booklet 1 Manual Conventions 2 Safety Rules 3 Fuel Safety 5 Controls and Features 6 Generator 6 Generator Panel 7 Parts Included 8 Wheel Kit 8 Other 8 Assembly 9 Remove the Generat...
Page 4 - ENGLISH; Introduction; Model Number; INTRODUCTION
1 REV 76555-20140718 ENGLISH 76555 Introduction Congratulations on your purchase of a Champion Power Equipment generator. CPE designs and builds generators to strict specifications. With proper use and maintenance, this generator will bring years of satisfying service. Portable Power Generator This ...
Page 5 - MANUAL CONVENTIONS; CAUTION; DANGER; WARNING
REV 76555-20140718 2 76555 ENGLISH MANUAL CONVENTIONS This manual uses the following symbols to help differentiate between different kinds of information. The safety symbol is used with a key word to alert you to potential hazards in operating and owning power equipment.Follow all safety messages to...
Page 6 - SAFETy RULES; When servicing the generator:
3 REV 76555-20140718 ENGLISH 76555 SAFETy RULES Generator exhaust contains carbon monoxide, a colorless, odorless, poison gas. Breathing carbon monoxide will cause nausea, dizziness, fainting or death. If you start to feel dizzy or weak, get to fresh air immediately. Operate generator outdoors only ...
Page 8 - When adding or removing Gas :
5 REV 76555-20140718 ENGLISH 76555 Gasoline and Gasoline Vapors (Gas) : – GAS IS HIGHLY FLAMMABLE AND EXPLOSIVE. – Gas can cause a fire or explosion if ignited. – Gas is a liquid fuel but it’s vapors can ignite. – Gas is a skin irritant and needs to be cleaned up immediately if spilled on skin or cl...
Page 9 - Generator; CONTROLS AND FEATURES
REV 76555-20140718 6 76555 ENGLISH Read this owner’s manual before operating your generator. Familiarize yourself with the location and function of the controls and features. Save this manual for future reference. (1) Gas Fuel Tank – 3.4 gal. (13 L) capacity fuel tank. (2) Choke – Used to start the ...
Page 10 - Generator Panel
7 REV 76555-20140718 ENGLISH 76555 Generator Panel 1 2 3 4 5 7 6 8 (1) Fuel Selector Switch – Used to select and turn on gas or LPG fuel source. (2) Ignition Switch – Used to start or stop the generator. (3) Intelligauge – Three mode digital meter for displaying running hours, voltage and hertz. (4)...
Page 11 - Parts Included; Wheel Kit
REV 76555-20140718 8 76555 ENGLISH Parts Included Your 76555 Dual Fuel Generator ships with the following parts: Wheel Kit – 8 in. (20.3 cm) Wheel 2 – Support leg w/ Vibration mounts 1 – Bushing 2 – Handle 1 – Flange Bolt (M10x105 for Wheel) 2 – Flange Bolt (M8x16 for support leg) 2 – Flange Bolt (M...
Page 12 - ASSEMBLy; Remove the Generator from the Shipping Carton; Connect the Battery
9 REV 76555-20140718 ENGLISH 76555 ASSEMBLy Your generator requires some assembly. This unit ships from our factory without oil. It must be properly serviced with fuel and oil before operation.If you have any questions regarding the assembly of your generator, call our help line at 1-877-338-0999. P...
Page 13 - Add Engine Oil; NOTE; Add Engine Oil Cont’d.
REV 76555-20140718 10 76555 ENGLISH 1. Place the generator on a flat, level surface. 2. Remove oil fill cap /dipstick to add oil.3. Add 0.6 qt. (0.6 L) of oil and replace oil fill cap/ dipstick. DO NOT OVERFILL. 4. Check engine oil level daily and add as needed. The recommended oil type is 10W-30 au...
Page 15 - Connecting LPG Cylinder Cont’d.; Grounding; Connecting Liquid Petroleum Gas (LPG) Cylinder
REV 76555-20140718 12 76555 ENGLISH ASSEMBLy Do not allow children to tamper or play with the cylinder or hose connections. CAUTION Use approved LPG cylinders equipped with an OPD (overfilling prevention device) valve. Always keep the cylinder in a vertical position with the valve on top and install...
Page 16 - OPERATION; Generator Location; Surge Protection
13 REV 76555-20140718 ENGLISH 76555 OPERATION Generator Location NEVER operate the generator inside any building, including garages, basements, crawlspaces and sheds, enclosure or compartment, including the generator compartment of a recreational vehicle. Please consult your local authority. In some...
Page 17 - Fuel Selector Switch; Gas; LPG
REV 76555-20140718 14 76555 ENGLISH OPERATION The fuel selector switch cover is specifically designed not to slide to either side while a specific fuel has been selected and the valve is in the “ON” position. Only when the fuel valves are in the “OFF” position can the cover slide side to side. NOTE ...
Page 18 - Connecting Electrical Loads; Starting the Engine Cont’d.
15 REV 76555-20140718 ENGLISH 76555 Connecting Electrical Loads 1. Let the engine stabilize and warm up for a few minutes after starting 2. Plug in and turn on the desired 120 Volt AC single phase, 60 Hz electrical loads. – DO NOT connect 3-phase loads to the generator. – DO NOT connect 50 Hz loads ...
Page 19 - Stopping the Engine; Do Not Overload Generator; Capacity
REV 76555-20140718 16 76555 ENGLISH Stopping the Engine 1. Turn off and unplug all electrical loads. Never start or stop the generator with electrical devices plugged in or turned on. 2. Let the generator run at no-load for several minutes to stabilize internal temperatures of the engine and generat...
Page 20 - Air Filter; MAINTENANCE AND STORAGE; Engine Maintenance; Oil
17 REV 76555-20140718 ENGLISH 76555 The owner/operator is responsible for all periodic maintenance. Complete all scheduled maintenance in a timely manner. Correct any issue before operating the generator. Never operate a damaged or defective generator. Tampering with the factory set governor will vo...
Page 21 - Adjustments; Spark Arrester; Generator Maintenance
REV 76555-20140718 18 76555 ENGLISH Adjustments The air-fuel mixture is not adjustable. Tampering with the governor can damage your generator and your electrical devices and will void your warranty. CPE recommends that you contact our service line at1-877-338-0999 for all other service and/or adjust...
Page 22 - Generator Storage; Generator Battery; Disconnect the Battery; Charge the Battery
19 REV 76555-20140718 ENGLISH 76555 MAINTENANCE AND STORAGE Storage The generator should be started at least once every 14 days and allowed to run for at least 20 minutes. For longer term storage, please follow these guidelines. Generator Storage 1. Add a properly formulated fuel stabilizer to the t...
Page 23 - SPECIFICATIONS
REV 76555-20140718 20 76555 ENGLISH Oil Use 10W-30 automotive oil.Oil capacity is up to 0.6 qt. (0.6 L). DO NOT OVERFILL.Please reference the following chart for recommended oil types for use in the generator. Fuel Fuel (Gas) capacity is 3.4 gal. (13 L). – Use regular unleaded gasoline with a minimu...
Page 24 - Parts Diagram
21 REV 76555-20140718 ENGLISH 76555 SPECIFICATIONS Parts Diagram 9 9 1 2 3 4 5 6 7 8 9 1 0 1 1 1 2 1 3 1 4 1 5 1 6 1 7 1 8 1 9 2 0 2 1 1 7 1 8 2 2 2 3 2 4 2 5 2 7 2 8 2 9 3 0 3 1 3 2 3 3 3 4 3 5 3 6 3 7 3 8 3 9 4 0 4 1 4 2 4 3 4 5 4 6 4 7 4 8 4 9 5 0 5 1 5 2 5 3 5 4 5 5 5 6 5 8 5 9 6 0 6 1 6 2 6 3 6...
Page 25 - Parts List
REV 76555-20140718 22 76555 ENGLISH Parts List # Part Number Description Qty 1 26.690 Engine 1 2 122.190005.00 Rubber, Fore- Cover, B 1 3 122.190005.01 Rubber, Fore- Cover, A 1 4 123.191100.21 Rotor Assembly, Al, 120 mm, CSA 1 5 2.08.022 Flange Bolt M8 ×242 1 6 1.96.08 Washer Ø8 1 7 1.7244.08 Lock W...
Page 26 - Engine Parts Diagram
23 REV 76555-20140718 ENGLISH 76555 SPECIFICATIONS Engine Parts Diagram 1 2 3 4 5 6 7 8 9 10 12 13 25 26 27 29 30 32 35 37 38 12 40 41 42 43 44 46 47 21 22 23 24 31 34 36 39 53 52 10 2 51 50 49 55 56 57 58 54 60 62 61 63 65 66 67 68 69 70 71 72 74 25 75 1 93 94 95 92 91 90 97 78 79 80 82 83 84 85 86...
Page 28 - Wiring Diagram
25 REV 76555-20140718 ENGLISH 76555 Wiring Diagram SPECIFICATIONS L W G B Y R YELLO W BLA C K B LU E G RE EN RE D WHI TE B r W H ITE B LU E GREEN YE LL OW W H ITE GREE N BRO W N BLACK W H IT E B/ W W/ L G /Y W /G B Y B /G E N GI N E BLO C K GENERA TO R BLO C K SPARKING P LU G IG N IT IO N C OI L O I...
Page 29 - TROUBLESHOOTING; For further technical support :
REV 76555-20140718 26 76555 ENGLISH TROUBLESHOOTING For further technical support : Technical ServiceMon – Fri 8:30 AM – 5:00 PM (PST/PDT)Toll Free: 1-877-338-0999tech@ championpowerequipment.com Problem Cause Solution Generator will not start No fuel Add fuel Faulty spark plug Replace spark plug Un...
Page 30 - WARRANTy; Installation, Use and Maintenance Cont’d.
27 REV 76555-20140718 ENGLISH 76555 WARRANTy WARRANT y CHAMPION POWER EQUIPMENT 2 YEAR LIMITED WARRANTY Warranty Qualifications Champion Power Equipment (CPE) will register this warranty upon receipt of your Warranty Registration Card and a copy of your sales receipt from one of CPE’s retail locatio...