Page 2 - Have questions or need assistance?; Call our Customer Care Team Toll-Free at:; AN IMPORTANT MESSAGE ABOUT TEMPERATURE:
*We are always working to improve our products. Therefore, the enclosed product may differ slightly from the image on the cover. Have questions or need assistance? Do not return this product to the store ! WE ARE HERE TO HELP! Visit our website: www.championpowerequipment.com for more info: • Produc...
Page 3 - TABLE Of CONTENTS; PORTABLE GENERATOR; Electric Start
100107 TABLE Of CONTENTS Introduction 1 Introduction 1 Portable Power Generator 1 Accessories 1 This Booklet 1 Manual Conventions 2 Safety Rules 3 Controls and Features 5 Generator 5 Power Panel 6 Parts Included 7 Wheel Kit 7 Other 7 Assembly 8 Remove the Generator from the Shipping Carton 8Install ...
Page 4 - ENGLISH; Introduction; Model Number; INTRODUCTION
1 REV 100107-20140923 ENGLISH 100107 Introduction Congratulations on your purchase of a Champion Power Equipment generator. CPE designs and builds generators to strict specifications. With proper use and maintenance, this generator will bring years of satisfying service. Portable Power Generator Thi...
Page 5 - MANUAL CONVENTIONS; CAUTION; DANGER; WARNING
REV 100107-20140923 2 100107 ENGLISH This manual uses the following symbols to help differentiate between different kinds of information. The safety symbol is used with a key word to alert you to potential hazards in operating and owning power equipment.Follow all safety messages to avoid or reduce ...
Page 6 - SAfETy RULES; When servicing the generator:
3 REV 100107-20140923 ENGLISH 100107 SAfETy RULES Generator exhaust contains carbon monoxide, a colorless, odorless, poison gas. Breathing carbon monoxide will cause nausea, dizziness, fainting or death. If you start to feel dizzy or weak, get to fresh air immediately. Operate generator outdoors onl...
Page 7 - When adding or removing fuel :
REV 100107-20140923 4 100107 ENGLISH SAfETy RULES Improper treatment or use of the generator can damage it, shorten its life and void your warranty. Use the generator only for intended uses.Operate only on level surfaces.DO NOT expose generator to excessive moisture, dust, or dirt.DO NOT allow any m...
Page 8 - Generator; CONTROLS AND fEATURES
5 REV 100107-20140923 ENGLISH 100107 Read this owner’s manual before operating your generator. Familiarize yourself with the location and function of the controls and features. Save this manual for future reference. (1) Fuel Tank – 6.1 gallon (23 L) capacity fuel tank. (2) Choke Lever – Used to star...
Page 9 - Power Panel
REV 100107-20140923 6 100107 ENGLISH Power Panel (1) Ignition Switch – Press the switch to the “START” position to start the generator, or to the “ON” position to start the generator manually. Flip to the “OFF” position to turn off the generator. (2) 120V/30A Twist-Lock (NEMA L5-30R) – May be used t...
Page 10 - Parts Included; Wheel Kit
7 REV 100107-20140923 ENGLISH 100107 Parts Included Your 100107 Gasoline Powered Generator ships with the following parts: Wheel Kit – 10 in. (25.4 cm) Wheel 2 – Bushing 2 – Flange Bolt (M10x120 for Wheel) 2 – Flat Washer ø10 2 – Lock Nut (M10) 2 – Support Leg w/vibration mounts 1 – Flange Bolt (M8x...
Page 11 - Remove the Generator from the Shipping Carton; Install the Wheel Kit; ASSEMBLy; Connect the Battery
REV 100107-20140923 8 100107 ENGLISH Your generator requires some assembly. This unit ships from our factory without oil. It must be properly serviced with fuel and oil before operation.If you have any questions regarding the assembly of your generator, call our help line at 1-877-338-0999. Please h...
Page 12 - Add Engine Oil; Add Engine Oil Cont’d.
9 REV 100107-20140923 ENGLISH 100107 ASSEMBLy Add Engine Oil Add Engine Oil Cont’d. 1. Place the generator on a flat, level surface. 2. Remove oil fill cap /dipstick to add oil.3. Add up to 1.2 qt. (1.1 L) of oil and replace oil fill cap/dipstick. DO NOT OVERFILL. 4. Check engine oil level daily and...
Page 13 - Grounding; Add fuel
REV 100107-20140923 10 100107 ENGLISH ASSEMBLy Grounding Your generator must be properly connected to an appropriate ground to help prevent electric shock. A ground terminal connected to the frame of the generator has been provided on the power panel. For remote grounding, connect of a length of hea...
Page 14 - OPERATION; Generator Location
11 REV 100107-20140923 ENGLISH 100107 Grounding The generator system ground connects the frame to the ground terminals on the power panel. Surge Protection Electronic devices, including computers and many programmable appliances use components that are designed to operate within a narrow voltage ran...
Page 15 - Connecting Electrical Loads; Starting the Engine; NOTE
REV 100107-20140923 12 100107 ENGLISH Connecting Electrical Loads 1. Let the engine stabilize and warm up for a few minutes after starting 2. Plug in and turn on the desired 120/240 Volt AC single phase, 60 Hz electrical loads. – DO NOT connect 3-phase loads to the generator. – DO NOT connect 50 Hz ...
Page 16 - Do Not Overload Generator; Capacity; Stopping the Engine
13 REV 100107-20140923 ENGLISH 100107 Do Not Overload Generator Capacity Follow these simple steps to calculate the running and starting watts necessary for your purposes. 1. Select the electrical devices you plan on running at the same time. 2. Total the running watts of these items. This is the am...
Page 17 - Air filter; Engine Maintenance; Oil; MAINTENANCE AND STORAGE
REV 100107-20140923 14 100107 ENGLISH Air filter 1. Remove the snap-on cover holding the air filter to the assembly. 2. Remove the foam element. 3. Wash in liquid detergent and water. Squeeze thoroughly dry in a clean cloth. 4. Saturate in clean engine oil. 5. Squeeze in a clean, absorbent cloth to ...
Page 18 - Adjustments; Maintenance Schedule; Generator Maintenance
15 REV 100107-20140923 ENGLISH 100107 Adjustments The air-fuel mixture is not adjustable. Tampering with the governor can damage your generator and your electrical devices and will void your warranty. CPE recommends that you contact our service line at1-877-338-0999 for all other service and/or adju...
Page 19 - Disconnect the Battery; Storage; Generator Storage; Generator Storage Cont’d.
REV 100107-20140923 16 100107 ENGLISH MAINTENANCE AND STORAGE Disconnect the Battery 1. Remove the protective cover from the black/negative battery lead. 2. Disconnect the black/negative lead from the black/ negative terminal on the battery and store the cap screw (M5x10) and lock washer (M5). 3. Re...
Page 20 - SPECIfICATIONS
17 REV 100107-20140923 ENGLISH 100107 fuel Fuel capacity is 6.1 gallons (23 L). Use regular unleaded gasoline with a minimum octane rating of 85 and an ethanol content of less than 10% by volume. Generator Specifications – Model 100107 – Rated Wattage 6500 Watts – Starting Wattage 7800 Watts – AC Vo...
Page 21 - Wiring Diagram; AVR
REV 100107-20140923 18 100107 ENGLISH Wiring Diagram SPECIfICATIONS AVR L W G B Y R YELL OW BLA C K B LU E G RE EN RE D WHI TE B r W H ITE B LU E GREEN YE LL OW W H ITE G R EE N BRO W N BLACK W H IT E B/ W W/ L G /Y W /G B W R G /Y G /Y Y Y W L L R W + M W 1 FW EX W In IND IGO EN GI NE BL O C K G EN...
Page 22 - Parts Diagram
19 REV 100107-20140923 ENGLISH 100107 Parts Diagram SPECIfICATIONS 16 17 18 19 20 28 29 30 31 32 33 34 30 35 36 37 38 37 39 40 41 42 43 44 45 46 47 48 30 36 49 51 52 53 54 84 73 76 77 78 79 81 82 83 85 55 58 17 59 60 61 62 63 64 65 66 67 68 69 71 72 74 19 80 75 75 86 21 22 23 24 25 56 50 50 57 48 1 ...
Page 23 - Parts List
REV 100107-20140923 20 100107 ENGLISH Parts List # Part Number Description Qty 1 122.070100.07 Fuel Tank Cap 1 2 122.070300.03 Fuel Filter 1 3 24.070800.00 Reversal Valve 1 4 2.06.006 Clamp (Ø7× Ø1) 1 5 24.070030.00 Hole, Breather Tube 1 6 152.070014.06 Pipe, Reversal Valve, 730 mm 1 7 2.05.001 Clam...
Page 24 - Engine Parts Diagram
21 REV 100107-20140923 ENGLISH 100107 Engine Parts Diagram SPECIfICATIONS 4 5 6 4 4 0 10 2 10 3 10 4 10 5 9 1 10 6 10 7 11 0 10 9 10 8 8 5 1 0 1 2 3 4 5 6 7 8 9 1 1 1 2 1 3 1 4 1 5 1 6 1 7 1 8 1 9 2 0 1 6 2 4 2 5 2 6 2 7 2 8 2 9 3 0 3 1 3 3 3 4 3 5 1 2 3 6 3 0 3 7 3 8 2 3 3 9 4 1 4 2 4 3 4 4 4 6 4 7...
Page 26 - TROUBLESHOOTING; for further technical support :
23 REV 100107-20140923 ENGLISH 100107 TROUBLESHOOTING Problem Cause Solution Generator will not start No fuel Add fuel Faulty spark plug Replace spark plug Unit loaded during start up Remove load from unit Generator will not start;Generator starts but runs roughly Low oil level Fill crankcase to the...
Page 27 - Installation, Use and Maintenance Cont’d.; WARRANTy
REV 100107-20140923 24 100107 ENGLISH WARRANT y CHAMPION POWER EQUIPMENT 2 YEAR LIMITED WARRANTY Warranty Qualifications Champion Power Equipment (CPE) will register this warranty upon receipt of your Warranty Registration Card and a copy of your sales receipt from one of CPE’s retail locations as p...