*We are always working to improve our products. Therefore, the enclosed product may differ slightly from the image on the cover. Have questions or need assistance? Do not return this product to the store ! WE ARE HERE TO HELP! Visit our website: www.championpowerequipment.com for more info: s Produc...
Page 3 - TABLE OF CONTENTS; PORTABLE GENERATOR; Electric Start
100102 TABLE OF CONTENTS Introduction 1 Introduction 1 Portable Power Generator 1 Accessories 1 This Booklet 1 Manual Conventions 2 Safety Rules 3 Controls and Features 5 Generator 5 Power Panel 6 Parts Included 7 Wheel Kit 7 Other 7 Assembly 8 Remove the Generator from the Shipping Carton 8Install ...
Page 4 - ENGLISH; Introduction; Model Number; INTRODUCTION
1 ENGLISH 100102 Introduction Congratulations on your purchase of a Champion Power Equipment generator. CPE designs and builds generators to strict specifications. With proper use and maintenance, this generator will bring years of satisfying service. Portable Power Generator This unit is a gasoline...
Page 5 - MANUAL CONVENTIONS; CAUTION; CAUTION; DANGER; WARNING
2 100102 ENGLISH This manual uses the following symbols to help differentiate between different kinds of information. The safety symbol is used with a key word to alert you to potential hazards in operating and owning power equipment.Follow all safety messages to avoid or reduce the risk of serious ...
Page 6 - SAFETY RULES; When servicing the generator:
3 ENGLISH 100102 SAFETY RULES Generator exhaust contains carbon monoxide, a colourless, odourless poison gas. Breathing carbon monoxide will cause nausea, dizziness, fainting or death. If you start to feel dizzy or weak, get to fresh air immediately. Operate generator outdoors only in a well ventila...
Page 7 - When adding or removing fuel :
4 100102 ENGLISH SAFETY RULES Improper treatment or use of the generator can damage it, shorten its life and void your warranty. Use the generator only for intended uses.Operate only on level surfaces.DO NOT expose generator to excessive moisture, dust, or dirt.DO NOT allow any material to block the...
Page 8 - Generator; CONTROLS AND FEATURES
5 ENGLISH 100102 Read this owner’s manual before operating your generator. Familiarize yourself with the location and function of the controls and features. Save this manual for future reference. (1) Fuel Tank – 23 L (6.1 gallon) capacity fuel tank. (2) Choke – Used to start the engine. (3) Fuel Val...
Page 9 - Power Panel
6 100102 ENGLISH Power Panel (1) Engine Switch – Press the switch to the “START” position to start the generator, or to the “ON” position to start the generator manually. Flip to the “OFF” position to turn off the generator. (2) 120/240V, 30A Twist-Lock Receptacle (NEMA L14-30R) – May be used to sup...
Page 10 - Parts Included; Wheel Kit
7 ENGLISH 100102 Parts Included Your 100102 gasoline powered generator ships with the following parts: Wheel Kit – 24.1 cm (9.5 in.) Wheel 2 – Bushing 2 – Flange Bolt (M10x110 for Wheel) 2 – Flat Washer Ø10 2 – Lock Nut (M10) 2 – Support Leg w/vibration mounts 1 – Flange Bolt (M8x16 for Support Leg)...
Page 11 - ASSEMBLY; Remove the Generator from the Shipping Carton; Connect the Battery
8 100102 ENGLISH ASSEMBLY Your generator requires some assembly. This unit ships from our factory without oil. It must be properly serviced with fuel and oil before operation.If you have any questions regarding the assembly of your generator, call our help line at 1-877-338-0999. Please have your se...
Page 12 - Add Engine Oil; Add Engine Oil Cont’d.
9 ENGLISH 100102 ASSEMBLY Add Engine Oil Add Engine Oil Cont’d. 1. Place the generator on a flat, level surface. 2. Remove oil fill cap /dipstick to add oil.3. Add up to 1.1 L (1.2 qt.) of oil and replace oil fill cap/dipstick. DO NOT OVERFILL. 4. Check engine oil level daily and add as needed. The ...
Page 13 - Grounding; Add Fuel
10 100102 ENGLISH ASSEMBLY Grounding Your generator must be properly connected to an appropriate ground to help prevent electric shock. A ground terminal connected to the frame of the generator has been provided on the power panel. For remote grounding, connect of a length of heavy gauge (12 AWG min...
Page 14 - OPERATION; Starting the Engine; Surge Protection; Generator Location
11 ENGLISH 100102 OPERATION Starting the Engine 1. Make certain the generator is on a flat, level surface.2. Disconnect all electrical loads from the generator. Never start or stop the generator with electrical devices plugged in or turned on. 3. Turn the fuel valve to the “ON” position.4. Flip the ...
Page 15 - Connecting Electrical Loads; Stopping the Engine; NOTE; Starting the Enging Cont’d.
12 100102 ENGLISH Connecting Electrical Loads 1. Let the engine stabilize and warm up for a few minutes after starting 2. Plug in and turn on the desired 120/240 Volt AC single phase, 60 Hz electrical loads. – DO NOT connect 3-phase loads to the generator. – DO NOT connect 50 Hz loads to the generat...
Page 16 - Do Not Overload Generator; Capacity; Power Management
13 ENGLISH 100102 Do Not Overload Generator Capacity Follow these simple steps to calculate the running and starting watts necessary for your purposes. 1. Select the electrical devices you plan on running at the same time. 2. Total the running watts of these items. This is the amount of power you ne...
Page 17 - Air Filter; Engine Maintenance; Oil; MAINTENANCE AND STORAGE
14 100102 ENGLISH Air Filter 1. Remove the snap-on cover holding the air filter to the assembly. 2. Remove the foam element. 3. Wash in liquid detergent and water. Squeeze thoroughly dry in a clean cloth. 4. Saturate in clean engine oil. 5. Squeeze in a clean, absorbent cloth to remove all excess oi...
Page 18 - Adjustments; Generator Maintenance; Maintenance Schedule
15 ENGLISH 100102 MAINTENANCE AND STORAGE Adjustments The air-fuel mixture is not adjustable. Tampering with the governor can damage your generator and your electrical devices and will void your warranty. CPE recommends that you contact our service line at 1-877-338-0999 for all other service and/or...
Page 19 - Disconnect the Battery; Storage; Generator Storage; Generator Storage Cont’d.
16 100102 ENGLISH MAINTENANCE AND STORAGE Disconnect the Battery 1. Remove the protective cover from the black/negative battery lead. 2. Disconnect the black/negative lead from the black/ negative terminal on the battery and store the flange bolt (M5x10) and flange nut (M5). 3. Repeat steps 1-2 for ...
Page 20 - SPECIFICATIONS
17 ENGLISH 100102 Fuel Fuel capacity is 23 L (6.1 gallons). Use regular unleaded gasoline with a minimum octane rating of 85 and an ethanol content of less than 10% by volume. Generator Specifications – Rated Wattage 7200 Watts – Starting Wattage 9000 Watts – AC Voltage 120/240 V – Phase Single – Fr...
Page 21 - Wiring Diagram; AVR
18 100102 ENGLISH Wiring Diagram SPECIFICATIONS AVR L W G B Y R YELLO W BLAC K BLUE GREE N RED WHIT E Br WHI T E B LU E GREEN YEL LO W WHI T E G R E E N BROW N BLACK WH IT E B/W W/L G/ Y W/ G B W R G/ Y G/ Y Y Y W L L R W + MW 1 FW EXW ENGINE B LO C K GENERATOR B LO C K EARTH TERMIN A L SPARKING P L...
Page 22 - Parts Diagram
19 ENGLISH 100102 Parts Diagram SPECIFICATIONS 16 17 18 19 20 26 27 28 29 30 31 32 28 33 34 35 36 35 37 38 39 40 41 42 43 44 45 46 28 34 47 49 50 51 52 21 22 25 48 1 2 3 4 5 6 8 9 10 11 12 13 14 15 9 53 54 55 17 56 57 58 59 60 61 62 63 64 65 46 66 67 68 69 70 70 71 72 73 74 75 76 77 78 79 80 81 48 8...
Page 23 - Parts List
20 100102 ENGLISH Parts List # Part Number Description Qty 1 122.070100.07 Fuel Tank Cap 1 2 122.070300.03 Fuel Filter 1 3 24.070800.00 Reversal Valve 1 4 2.06.006 Clamp (Ø7 × Ø1) 1 5 24.070030.00 Hole, Breather Tube 1 6 152.070014.08 Pipe, Reversal Valve, 710 mm 1 7 2.05.001 Clamp (Ø8 × 6.5) 2 8 1....
Page 24 - Engine Parts Diagram
21 ENGLISH 100102 Engine Parts Diagram SPECIFICATIONS 4 5 6 4 4 0 10 2 10 3 10 4 10 5 9 1 10 6 10 7 11 0 10 9 10 8 8 5 1 0 1 2 3 4 5 6 7 8 9 1 1 1 2 1 3 1 4 1 5 1 6 1 7 1 8 1 9 2 0 1 6 2 4 2 5 2 6 2 7 2 8 2 9 3 0 3 1 3 3 3 4 3 5 1 2 3 6 3 0 3 7 3 8 2 3 3 9 4 1 4 2 4 3 4 4 4 6 4 7 4 8 4 9 5 0 5 1 5 2...
Page 26 - TROUBLESHOOTING; For further technical support :
23 ENGLISH 100102 TROUBLESHOOTING For further technical support : Technical Service Mon – Fri 8:30 AM – 5:00 PM (PST/PDT)Toll Free: 1-877-338-0999tech@ championpowerequipment.com Problem Cause Solution Generator will not start No fuel Add fuel Faulty spark plug Replace spark plug Unit loaded during ...
Page 27 - Installation, Use and Maintenance Cont’d.; WARRANTY
24 100102 ENGLISH WARRANT Y CHAMPION POWER EQUIPMENT 2 YEAR LIMITED WARRANTY Warranty Qualifications Champion Power Equipment (CPE) will register this warranty upon receipt of your Warranty Registration Card and a copy of your sales receipt from one of CPE’s retail locations as proof of purchase.Ple...