Page 3 - SP; Table
3 MAXIMUM DESIGN WORKING PRESSURE – 45 PSI; W A TER ONL Y Figure 1 SP ACEMASTER W ALL MOUNTED GAS BOILER – DIMENSIONAL DA T A I. General Installation Requirements ................... 4 II. Installation Instructions ..................................... 7 III. Operating Instructions ....................
Page 4 - I. General Installation Requirements; above; Figure 2
4 I. General Installation Requirements 1 I N S P E C T S H I P M E N T carefully for any signs of damage. All equipment is carefully manufactured, inspected and packed. Our responsibility ceases upon delivery of Boiler to the carrier in good condition. Any claims for damage or shortage in shipment m...
Page 5 - A minimum of 24”; Figure 3
5 Minimum listed clearances from combustible materials for non-closet installation or closet installation. (See Figure 3). Top — 6” *Left Side —1” Rear — 0” Right Side — 1” *Front — 2” Flue — 0” Floor — 6” Since the above dimensions are measured between boiler jacket and combustible walls or ceiling...
Page 6 - TABLE II; il; TABLE III
6 TABLE II *NOTE – For all practical purposes, each 90° elbow can be considered as the following equivalent in length of straight pipe: ½” – 1.6 ft. 1” – 2.6 ft. ¾” – 2.1 ft. f o t e e F c i b u C n i g n i p i P f o y t i c a p a C m u m i x a M r u o H r e P s a G d n a r e t a W " 5 . 0 f o p...
Page 7 - II. Installation Instructions; Standard
7 II. Installation Instructions DETERMINE BEST MOUNTING LOCATION for boiler which meets site requirements outlined in Section I, pages 4 through 6. 1 I N S T A L L I N G B O I L E R M O U N T I N G W A L L B R A C K E T (See Figure 5). a. Locate wall bracket packed in miscellaneous parts carton. b. ...
Page 8 - Figure 4; Figure 5
8 h. Secure boiler to boiler mounting wall bracket with fi ve (5) ¼”-20 x ¾” long machine screws and washers provided. NOTE: Tools required — 7/16” socket, extension bar(s) and drive ratchet i. Secure interior telescoping intake air duct to back plate of boiler. Pull duct forward until duct and weld...
Page 10 - Figure 6
10 e. A hot water boiler installed above radiation level must be provided with a low water cutoff device as part of the installation. If a low water cut-off is required, it must be mounted in the system piping above the boiler. The minimum safe water level of a hot water boiler is just above the hig...
Page 13 - III. Operating Instructions
13 Safe lighting and other performance criteria were met with the gas manifold and control assembly provided on the boiler when the boiler underwent tests specifi ed in ANSI Z21.13. 1 I N S P E C T I N S T A L L A T I O N B E F O R E S T A R T I N G . 2 I N I T I A L S T A R T a. F I L L E N T I R E...
Page 14 - THESE OPERATING INSTRUCTIONS:
14 NOTE: YOUR BOILER IS EQUIPPED WITH A HONEYWELL VR8204 OR VR8304 GAS VALVE. PLEASE FOLLOW THESE OPERATING INSTRUCTIONS:
Page 15 - Figure 1
Page 18 - min. = 20000
18 Use the Trouble Shooting Guide (pages 19 to 21) to assist in locating where a malfunction in the control system is occurring. 4 P R O C E D U R E F O R M E A S U R I N G F A N DIFFERENTIAL PRESSURE (See Figure 13). a. With boiler off, remove black silicone tubing from low side of pressure switch....
Page 25 - Warning; AVOID Breathing Fiber Particulates and Dust; Precautionary Measures; A National Institute for Occupational Safety and Health (NIOSH); First Aid Procedures
25 Warning : This product contains refractory ceramic fi bers (RCF). RCF has been classifi ed as a possible human carcinogen. After this product is fi red, RCF may, when exposed to extremely high temperature (>1800F), change into a known human carcinogen. When disturbed as a result of servicing o...
Page 27 - connection must have a; minimum; diameter to
27 A 24 VAC LWCO is used primarily for gas fi red boilers where a 24 volt control circuit exists within the boiler. However, a 24 VAC LWCO can only be used if the boiler manufacturer has provided piping and wiring connections and instructions to allow for this application. How to Test Shut off fuel ...
Page 28 - Limited Warranty; FOR RESIDENTIAL CAST IRON WATER BOILERS
Boiler Co., Inc. recommendations and hydronics industry standards. These warranties will be inapplicable if the residential grade water boiler is used or operated over its rated capacity, is subjected to unauthorized modifi cation, or is damaged as a result of being otherwise improperly operated or ...