Page 2 - TO ENTER THE CONFIGURATION MODE:; Option 01—Anticipator Adjustment

III. INSTALL THERMOSTAT WARNING: ELECTRICAL SHOCK HAZARD Failure to follow this warning could result in personalinjury or death.Before installing thermostat, turn off all power to unit.There may be more than 1 power disconnect. 1. Turn OFF all power to unit. 2. If an existing thermostat is being rep...

Page 5 - Terminating Installer Test

6. Use up and down buttons to select another Option, or press FAN button to exit configuration mode. M. Option 19 — Equipment Present This selection informs the thermostat of the heat, cool, and fancapabilities of the installed equipment. Select number 2, 3, or 4.Default is 4.For equipment with both...

Page 6 - TABLE 2—NON-PROGRAMMABLE -C THERMOSTAT QUICK REFERENCE; THERMOSTAT OUTPUT; Fig 4—Single-Speed Air Conditioner

TABLE 2—NON-PROGRAMMABLE -C THERMOSTAT QUICK REFERENCE THERMOSTAT OUTPUT TSTAT Model Outdoor Unit Option 5 24v Hot Common Fan Heat Stage 1 Heat Stage 2 Heat Stage 3 Cool Stage 1 Cool Stage 2 Reversing Valve AC01-C AC N/A R C G W/W1 N/A N/A Y/Y2 N/A N/A HP01-C HP OFF R C G Y/Y2 W/W1 N/A Y/Y2 N/A O/W2...