Page 2 - Model number nomenclature; Climate Map for Energy and Heat Recovery Ventilators
2 HRV LHA 1 150 Model number nomenclature Equipment Type:Heat Recovery Ventilator Electrical Supply:1 --- 115 Volts Maximum Capacity: 100 CFM 150 CFM 250 CFM Descriptor (A Series): LHA --- Large Horizontal SVA --- Small Vertical SHA --- Small Horizontal BB Brand:Bryant Climate Map for Energy and Hea...
Page 3 - Controls and accessories part number nomenclature; Kit Number
3 K 01 Controls and accessories part number nomenclature K --- Accessory Kit CONTROL DESCRIPTION BAU --- Bryant Automatic Control BBS --- Bryant Basic Control BST --- Bryant Standard Control ACCESSORY DESCRIPTION 6FM --- 6 in. Flowmeters (2) 7FM --- 7 in. Flowmeters (2) 8FM --- 8 in. Flowmeters (2) ...
Page 4 - Control Features; Offers automatic dehumidistat control and the option to select; Automatic Defrost Cycle Features; All models offer a non--electric defrost cycle feature which
4 Control Description Fan Speed Control Dehumidistat Control Continuous Mode Intermittent Mode OneTouch Yes No Yes Yes Basic Yes No Yes No Standard Yes Yes Yes Yes Control Features Basic Control: Allows the user to manually set fan speed to low or high asrequired to maximize comfort. Standard Contro...
Page 6 - Physical data; Model
6 A05426 Fig. 2 -- HRVBBSHA Unit Dimensions A05425 Fig. 3 -- HRVBBSVA Unit Dimensions Physical data Model HRVBBLHA1150 HRVBBLHA1250 HRVBBSVA1100 HRVBBSHA1100 Port Locations Side Side Top Side Core Type Polypropylene Polypropylene Polypropylene Polypropylene Core Type Polypropylene Cross Flow Polypro...
Page 7 - Methods to Size HRVs; people; Additional heating and cooling load charts; Outside Temp; The heating load chart shows the heating loads in BTUh for a
7 Physical data (continued) Model HRVBBLHA1150 HRVBBLHA1250 HRVBBSVA1100 HRVBBSHA1100 Capacity—CFM @ 0.5-0.3ESP (in. wc) 130 --- 168 191 --- 210 99 --- 107 99 --- 107 Efficiency (Sensible)—Percent 65 65 66 66 Efficiency (Sensible) Percent 32 _ F (0 _ C) -- 13 _ F ( -- 25 _ C) 65 65 65 60 66 66 66 66...
Page 8 - COOLING LOAD BTU; Outside; The cooling load chart shows the loads in BTUh also. To use the
8 COOLING LOAD BTU Outside Cooling Load (BTUh) @ Inside Design Temp 75 ° F and 50% Relative Humidity Outside Enthalpy BTU/lb HRVBBLHA1150 HRVBBLHA1250 30 670 1,071 31 1,090 1,741 32 1,509 2,411 33 1,928 3,080 34 2,347 3,750 35 2,766 4,419 36 3,185 5,089 37 3,604 5,759 38 4,023 6,428 39 4,442 7,098 4...