Page 2 - BOILER ACCESSORIES; MODEL NUMBER NOMENCLATURE
—2— BOILER ACCESSORIES BW1/BW2 DESCRIPTION PART NO. Filtrol Package (Up to 75,000 Btuh Input) KBAFP0101DNK Filtrol Package (Up to 150,000 Btuh Input) KBAFP0201DNK Filtrol Package (Over 150,000 Btuh Input) KBAFP0301DNK High Limit Control KBAHL0101DNK Combustible Floor Base (2 thru 6 section models) K...
Page 4 - WATER BOILER CIRCULATOR CURVE; ama; ASME
—4— CIRCULATOR CURVE ELECTRICAL DATA STANDARD BOILER WARRANTIES (Yrs) ALL MODELS Voltage—Hertz—Phase 115 — 60 — 1 Minimum Branch Circuit Wire Size (AWG) 14 Maximum Fuse Size (Amps) 15 Control Circuit Power Available 40va–@ 24v MODEL BW1 BW2 BW3 BW4 BW5 BW9 BS1 BS2 Circulator Pump 3 3 3 3 3 3 — — Ven...
Page 5 - FEATURES; SPECIFICATIONS; MODELS BW9
—5— The BW9, unlike normal residential atmospheric and induced draftboilers, takes its combustion air directly from the outdoors (sealedcombustion) and does not compete with building occupants forfresh air. Sealed combustion (also known as “direct vent”) is thesafest and best way to obtain plenty of...
Page 6 - DIMENSIONS; MODEL BW9; RATINGS AND CAPACITIES; CLEARANCES
—6— DIMENSIONS MODEL BW9 ALTERNATE SUPPLY& RETURN OPENINGS(1-1/4" NPT (31.75mm) CONNECTIONSPROVIDED INSIDEBOILER CABINET) ACCESS PANEL ALTERNATE OPENINGFOR GAS SUPPLY BOILER WATER TEMPERATURE& PRESSURE GAUGE FRONT PANEL DOOR PULL LEVELING FEET CONDENSATEDRAIN FITTING (1/2" PVC) (12.7...
Page 7 - MODELS BS1 and BS2
—7— SPECIFICATIONS * Factory authorized and listed, field installed. UNIT SIZE 075 112 150 187 225 262 299 GENERAL DATA Sections—Fine Grain Cast Iron No. 3 4 5 6 7 8 9 Burners—Stainless/Titanium Alloy No. 2 3 4 5 6 7 8 Burners—Orifice Drill Size Natural 34 34 34 34 34 34 34 GAS CONTROLS — STANDING P...
Page 9 - MODELS BW1 and BW2
—9— Models BW1 and BW2 Gas-Fired Hot Water Boilers providefast heat quietly and economically to assure the finest inhydronic heating.These boilers provide quality design in a small, compact uniteasily installed in a basement, garage, or utility room. Theycan be installed on a combustible floor when ...
Page 10 - BW1 and BW2 MODELS
—10— DIMENSIONS BW1 and BW2 MODELS 23 1 ⁄ 4 ″ 31 3 ⁄ 8 ″ 5 3 ⁄ 8 ″ 4 3 ⁄ 4 ″ 1 1 ⁄ 4 ″ SUPPLY 26 1 ⁄ 2 ″ 12 1 ⁄ 4 ″ A 8 ″ TEMPERATURE/ PRESSURE GAGE SPILL SWITCH DRAIN VALVE INT. PILOT CONTROL ROLLOUT SWITCH GASVALVE 1 1 ⁄ 4 ″ RETURN 1 1 ⁄ 4 ″ NPT AQUASTAT VENT DAMPER ASME RELIEF VALVE LEFT SIDE RIG...
Page 11 - Each section is hydrostatically tested to; MODEL BW3
—11— SPECIFICATIONS UNIT SIZE 042 075 112 150 187 225 Sections—Fine Grain Cast-Iron No. 2 3 4 5 6 7 GAS CONTROLS — INTERMITTENT PILOT Gas Valve Honeywell Inlet Size In. 1/2 FPT Pilot Assembly Honeywell Spark Generator Honeywell Burners—Stainless/Titanium Alloy No. 1 2 3 4 5 6 Burner Orifice—Drill Si...
Page 12 - BW3 MODELS
—12— DIMENSIONS BW3 MODELS 29 ″ 23 ″ 25 1 ⁄ 4 ″ 23 1 ⁄ 4 ″ 5 5 ⁄ 8 ″ 5 5 ⁄ 8 ″ 1 3 ⁄ 4 ″ 7 ″ A GASVALVE INT. PILOTCONTROL PRESSURESWITCH BLOWER VENTCONNECTOR COMBINATIONLIMIT & RELAYCONTROL 1 1 ⁄ 4 ″ SUPPLY RELIEFVALVE BURNER TEMP PRESSURE GAGE 1 1 ⁄ 4 ″ RETURN CIRCULATOR LEFT SIDE RIGHT SIDE FR...
Page 13 - MODELS BW4 and BW5
—13— The modern design and attractive appearance of the modelsBW4 and BW5 Oil-Fired Water Boilers make them ideal forinstallation in any area. The boilers are shipped fullyassembled and wired, including all controls (except barometricdraft regulator). The compact 22-gage steel cabinet has abaked-on ...
Page 14 - RATINGS AND PERFORMANCE
—14— DIMENSIONS MODELS BW4 and BW5 A 19 5 ⁄ 8 ″ GAGE 36 ″ 1 1 ⁄ 4 ″ RETURN 1 1 ⁄ 4 ″ SUPPLY CONTROL TANKLESSHEATER 1 ⁄ 2 ″ N.P.T. 9 ″ C B 3 ⁄ 4 ″ ASME RELIEF VALVE FRONT SIDE REAR DIMENSIONS (In .) UNIT SIZE A B C 140 17-3/4 6 9-3/4 210 21 6 11-3/8 280 24-1/4 6 13 CLEARANCES (In. ) * Clearance 18 in...