Summary

Page 2 - DIMENSIONS

— 2 — DIMENSIONS A94148 ACCESS PANEL 1 1 / 4 " 1. Allow 30 in. clearance to service end of unit, 48 in. above unit, 6 in. on one side, 12 in. on remaining side, and 24 in. between units for proper airflow. Minimum outdoor operating ambient in cooling mode is 55 ° F (unless low ambient control is...

Page 4 - SPECIFICATIONS

— 4 — SPECIFICATIONS See notes on page 5. UNIT SIZE-SERIES 018-B 024-B 030-B 036-B 042-B Operating Weight (Lb) 198 198 221 211 231 ELECTRICAL Unit Volts-Hertz-Phase 208/230-60-1 Operating Voltage Range 187—253 Unit Ampacity for Wire Sizing 16.1 17.5 18.7 21.0 32.0 Min Wire Size (60 ° C/75 ° C Copper...

Page 5 - SPECIFICATIONS Continued

— 5 — SPECIFICATIONS Continued * If wire is applied at ambient greater than 30 ° C (86 ° F), consult Table 310-16 of the NEC (ANSI/NFPA 70). If other than uncoated (non-plated), 60 ° or 75 ° C (140 ° or 167 ° F) insulation, copper wire (solid wire for 10 AWG and smaller, stranded wire for larger tha...