Page 2 - MODEL NUMBER NOMENCLATURE; A A A D; Low NO; unit; LEGEND; Aluminum; CU –; Copper
2 Low Sound Ratings ensure a quiet indoor and outdoor environ- ment with sound ratings as low as 7.5 bels. (See ARI capacitycharts for individual values.) Easy-to-Service Cabinets provide easy single-panel acces- sibility to serviceable components during maintenance andinstallation. The basepan with...
Page 4 - PHYSICAL DATA
PHYSICAL DATA UNIT SIZE 582A 018040 024040 024060 030040 030060 036060 036090 042060 042090 NOMINAL CAPACITY (ton) 1 1 / 2 2 2 2 1 / 2 2 1 / 2 3 3 3 1 / 2 3 1 / 2 OPERATING WEIGHT (lb) 249 280 280 280 280 314 314 355 355 COMPRESSOR(S) – QUANTITY Reciprocating-1 REFRIGERANT (R-22) Quantity (lb) 2.6 3...
Page 5 - OPTIONS AND ACCESSORIES; FACTORY-INSTALLED OPTIONS; Solid-State Time Guard
OPTIONS AND ACCESSORIES FACTORY-INSTALLED OPTIONS Louvered Grille provides hail guard and vandalism protection.A wire grille is standard on all models. See model number no-menclature for louvered grille options. Coil Options include copper/copper and vinyl-coated construc-tion for refrigerant coils....
Page 9 - ACCESSORY DIMENSIONS; UNIT SIZE; Full Perimeter Curb
ACCESSORY DIMENSIONS UNIT SIZE 582A ODS ORDER NUMBER A in. [mm] B in. [mm] C in. [mm] D in. [mm] FLAT CURB 018-042 CPRFCURB006A00 8 [203] 11 27 / 32 [301] 30 5 / 8 [778] 28 3 / 4 [730] CPRFCURB007A00 14 [356] 11 27 / 32 [301] 30 5 / 8 [778] 28 3 / 4 [730] 048,060 CPRFCURB008A00 8 [203] 15 27 / 32 [4...
Page 11 - See Legends and Notes on page 13.
PERFORMANCE DATA NET COOLING CAPACITIES 582A018 TEMP (F) OUTDOOR-AIR ENTERING CONDENSER EVAPORATOR AIR—CFM/BF 525/0.118 Evaporator Air—Ewb (F) 62 67 72 62 67 72 62 67 72 85 TC 15.7 18.5 20.9 16.5 19.2 21.5 17.2 19.8 21.9 SHC 13.5 11.6 9.5 14.9 12.7 10.2 16.2 13.6 10.7 kW 1.75 1.80 1.83 1.77 1.81 1.8...
Page 14 - DRY COIL AIR DELIVERY*—HORIZONTAL AND DOWNFLOW DISCHARGE
PERFORMANCE DATA (cont) DRY COIL AIR DELIVERY*—HORIZONTAL AND DOWNFLOW DISCHARGE (Deduct 10% for 208 v) 230 AND 460 VOLT Unit 582A Motor Speed External Static Pressure (in. wg) 0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 018 Low Watts 227 212 196 177 165 153 CFM 1082 1016 929 796 668 428 — — — — — —...
Page 15 - * As the height above sea level increases, there is less; HIGH ALTITUDE COMPENSATION; PROPANE GAS ONLY; * As the height above sea level increases, there is less oxygen per
PERFORMANCE DATA (cont) ECONOMIZER/1-IN. FILTER PRESSURE DROP UNIT 582A PRESSURE DROP (in. wg) 018-042 0.12 048, 060 0.24 WET COIL PRESSURE DROP UNIT 582A AIRFLOW (CFM) PRESSURE DROP (in. wg) 018 500 0.049 600 0.070 700 0.095 024 700 0.077 800 0.100 900 0.127 030 900 0.065 1000 0.080 1100 0.097 036 ...
Page 16 - National Electrical Code; Horizontal Discharge
TYPICAL PIPING AND WIRING Vertical Discharge *NEC – National Electrical Code Horizontal Discharge 16 INDOORTHERMOSTAT DISCONNECTPER NEC* FROMPOWERSOURCE RETURNAIR TOP COVER FROMGAS LINE *NEC - NATIONAL ELECTRICAL CODE Horizontal Discharge
Page 17 - APPLICATION DATA
17 APPLICATION DATA 1. CONDENSATE TRAP —A 2-in. condensate trap must be field supplied. 2. DUCTWORK —Secure downflow discharge ductwork to roof curb. For horizontal discharge applications, attachductwork to unit with flanges. 3. TO CONVERT A UNIT TO DOWNFLOW DISCHARGE — Units are equipped with facto...
Page 21 - ELECTRICAL DATA
ELECTRICAL DATA UNIT SIZE 582A V-PH-Hz VOLTAGE RANGE COMPRESSOR COND FAN MOTOR INDOOR FAN MOTOR POWER SUPPLY Min Max RLA LRA FLA FLA MCA MOCP* 018 208/230-1-60 187 253 9.0 45.0 0.8 1.8 13.9 20 024 208/230-1-60 187 253 12.8 61.0 0.8 2.0 18.8 30 030 208/230-1-60 187 253 14.4 73.0 0.8 2.0 20.8 30 036 0...
Page 22 - CONTROLS; OPERATING SEQUENCE
CONTROLS OPERATING SEQUENCE Heating — When the thermostat calls for heating, terminal “W”is energized, starting the induced-draft motor. When the hall-effect sensor on the induced-draft motor senses that it hasreached the required speed, the burner ignition sequence be-gins. The indoor (evaporator) ...
Page 23 - GUIDE SPECIFICATIONS; PART 1 — GENERAL
GUIDE SPECIFICATIONS PACKAGED HEATING/COOLING UNITSCONSTANT VOLUME APPLICATION HVAC GUIDE SPECIFICATIONS SIZE RANGE: 1 1 / 2 TO 5 TONS, NOMINAL COOLING 40,000 TO 130,000 BTUH,NOMINAL HEATING INPUT BRYANT MODEL NUMBER: 582A PART 1 — GENERAL SYSTEM DESCRIPTION Outdoor rooftop mounted or ground level i...
Page 24 - Heating & Cooling Systems
GUIDE SPECIFICATIONS (cont) K. Electrical Requirements: All unit power wiring shall enter the unit cabinet at asingle location. L. Motors: 1. Compressor motors shall be of the refrigerant-cooled type with line-break thermal and current overloadprotection. 2. All fan motors shall have permanently lub...