Page 2 - DIMENSIONS
—2— DIMENSIONS AIR DISCHARGE AIR DISCHARGE AIR IN AIR IN AIR IN 3 / 8 " DIA. TIEDOWN KNOCKOUTS (2) PLACES L K J E D C L NOTES: 1. ALLOW 30" CLEARANCE TO SERVICE SIDE OF UNIT, 48" ABOVE UNIT, 6" ON ONE SIDE, 12" ON REMAINING SIDE, AND 24" BETWEEN UNITS FOR PROPER AIRFLOW. 2. M...
Page 3 - MODEL NUMBER NOMENCLATURE; – 2 ton
—3— RECOMMENDED TUBE DIAMETERS * For tube sets greater than 50 ft and/or 20 ft vertical differential, consult Application Guideline and Service Manual—Air Conditioners and Heat Pumps UsingPuron® Refrigerant. CHECK-FLO-RATER® PISTON * Piston listed is for any approved non-capillary tube coil combina-...
Page 4 - SPECIFICATIONS
—4— SPECIFICATIONS See notes on page 5. UNIT SIZE-SERIES 018-F 024-F/G 030-F 036-F/G Operating Weight (Lb) 168 209 209 212 ELECTRICAL Unit Volts—Hertz—Phase 208/230—60—1 Operating Voltage Range* 187—253 Compressor— Rated Load Amps 10.3 13.5/12.8 14.7 16.7/15.4 Locked Rotor Amps 51.0 61.0/60.0 72.5 8...
Page 5 - SPECIFICATIONS Continued
—5— SPECIFICATIONS Continued * Permissible limits of the voltage range at which the unit will operate satisfactorily. Operation outside these limits may result in unit failure. † If wire is applied at ambient greater than 30°C (86°F), consult Table 310-16 of the NEC (ANSI/NFPA 70). The ampacity of n...
Page 8 - COMBINATION RATINGS
—8— COMBINATION RATINGS UNIT SIZE-SERIES INDOOR UNIT TOT. CAP. BTUH FACTORY-SUPPLIED ENHANCE- MENT SEER EER Standard Rating Bryant Gas Furnace or Accessory TDR† Accessory Puron TXV‡ 018-F *CK5A/CK5BA024 17,500 NONE — 12.00 12.00 10.80 CC5A/CD5AA018 17,200 NONE — 11.50 11.50 10.45 CC5A/CD5AA024 17,50...
Page 9 - COMBINATION RATINGS Continued
—9— 024-F CK5A/CK5BW030 23,200 TDR 13.00 — 13.00 11.20 CK5PA024 23,000 TDR&TXV 12.50 — — 11.10 CK5PA030 23,200 TDR&TXV 13.00 — — 11.20 CK5PW024 23,000 TDR&TXV 12.50 — — 11.10 CK5PW030 23,200 TDR&TXV 13.00 — — 11.20 COILS + 355MAV042040 VARIABLE-SPEED FURNACE CC5A/CD5AW030 23,200 TDR ...
Page 19 - EER; SEER; TDR
—19— * Tested combination. † In most cases, only 1 method should be used to achieve TDR function. Using more than 1 method in a system may cause degradation in performance. Use either the accessory Time-Delay Relay KAATD0101TDR or a furnace equipped with TDR. Most Bryant furnaces are equipped with T...
Page 20 - DETAILED COOLING CAPACITIES*
—20— DETAILED COOLING CAPACITIES* See notes on page 32. EVAP AIR CONDENSER ENTERING AIR TEMPERATURES °F 75 85 95 105 115 125 CFM EWB Capacity MBtuh† Total Sys kW** Capacity MBtuh† Total Sys kW** Capacity MBtuh† Total Sys kW** Capacity MBtuh† Total Sys kW** Capacity MBtuh† Total Sys kW** Capacity MBt...
Page 21 - DETAILED COOLING CAPACITIES* continued
—21— DETAILED COOLING CAPACITIES* continued See notes on page 32. EVAP AIR CONDENSER ENTERING AIR TEMPERATURES °F 75 85 95 105 115 125 CFM EWB Capacity MBtuh† Total Sys kW** Capacity MBtuh† Total Sys kW** Capacity MBtuh† Total Sys kW** Capacity MBtuh† Total Sys kW** Capacity MBtuh† Total Sys kW** Ca...
Page 24 - DETAILED COOLING CAPACITIES* Continued
—24— DETAILED COOLING CAPACITIES* Continued See notes on page 32. EVAP AIR CONDENSER ENTERING AIR TEMPERATURES °F 75 85 95 105 115 125 CFM EWB Capacity MBtuh† Total Sys kW** Capacity MBtuh† Total Sys kW** Capacity MBtuh† Total Sys kW** Capacity MBtuh† Total Sys kW** Capacity MBtuh† Total Sys kW** Ca...
Page 33 - CONDENSER ONLY RATINGS*; SST
—33— CONDENSER ONLY RATINGS* See notes on page 35. SST °F CONDENSER ENTERING AIR TEMPERATURES °F 55 65 75 85 95 105 115 125 552AN018-F 30 TCG 16.0 15.1 14.3 13.4 12.4 11.5 10.5 9.50 SDT 67.7 77.4 87.0 96.7 106.4 116.1 125.8 135.2 KW 0.80 0.92 1.06 1.21 1.38 1.56 1.76 1.97 35 TCG 17.6 16.6 15.7 14.8 ...
Page 34 - CONDENSER ONLY RATINGS* Continued
—34— CONDENSER ONLY RATINGS* Continued See notes on page 35. SST °F CONDENSER ENTERING AIR TEMPERATURES °F 55 65 75 85 95 105 115 125 552AN030-F 30 TCG SDT KW 26.771.21.41 25.380.91.59 23.890.61.80 22.4100.2.04 21.0110.2.30 19.5120.2.59 18.0129.2.91 16.4139.3.26 35 TCG SDT KW 29.372.51.42 27.882.11....
Page 35 - SYSTEM DESIGN SUMMARY; Do not apply capillary tube indoor coils to these units.
—35— SYSTEM DESIGN SUMMARY 1. Intended for outdoor installation with free air inlet and outlet. Outdoor fan external static pressure available is less than 0.01-in. wc.2. Minimum outdoor operating air temperature without low-ambient operation accessory is 55°F (12.8°C).3. Maximum outdoor operating a...
Page 36 - GUIDE SPECIFICATIONS; GENERAL
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE UNIT MUST BE INSTALLED IN ACCORDANCE WITH INSTALLATION INSTRUCTIONS Cancels: PDS 552A.18.2 New: PDS 552A.18.3 © 2003 Bryant Heating & Cooling Systems, 7310 W. Morris St. Indpls, IN 46231 — 36 — PRINTED IN U.S.A. Catalog No. 5255-206 10-03 GUIDE SPE...