Page 2 - FURNACE SIZE

ELECTROSTATIC DISCHARGE (ESD) PRECAUTIONS PROCEDURE CAUTION: Electrostatic discharge can affect electronic components. Take precautions during furnace installationand servicing to protect the furnace electronic control andmotor. Precautions will prevent electrostatic dischargesfrom personnel and han...

Page 3 - FURNACE; Side Return; Fig. 4—Upflow/Horizontal Component Identification

a. Turn off electrical supply before removing blower and control access doors. b. Release filter retainer from clip at front of furnace casing. (See Fig. 4.) For side return, clips may be usedon either or both sides of the furnace. c. Slide filter out. d. Clean filters by spraying tap water through ...

Page 5 - Electrical Controls and Wiring; There may be more than 1 electrical supply to unit.; Troubleshooting

g. Flame-sensing electrode. h. Wiring connectors leading to control. 12. Reconnect vent pipe to relief box. 13. Replace blower door only. 14. Turn power and gas to ON. 15. Set thermostat and check furnace for proper operation. 16. Verify blower airflow and that airflow rate changes between heating a...