Page 2 - MODEL NUMBER NOMENCLATURE; STANDARD FEATURES; Feature
2 MODEL NUMBER NOMENCLATURE 1 2 3 4 5 6 7 8 9 10 11 12 14 N N N A A/N N N N N A/N A/N N A 2 1 3 R N A 0 3 6 0 0 0 0 Prod- uct Family Tier SEER Major Series Voltage Variations Cooling Capacity Open Open Open Series 2=HP 1= Legacy RNC 3=13 SEER R=R --- 22 N= 208/230 --- 1 P=208/230 --- 3 E=460/3 A = S...
Page 3 - PHYSICAL DATA; VAPOR LINE SIZING AND COOLING CAPACITY LOSS
3 PHYSICAL DATA UNIT SIZE --- SERIES 018 --- A 024 --- A 030 --- A 036 --- A 042 --- A 048 --- A 060 --- A Operating Weight (lb) 159 160 208 211 233 269 295 Shipping Weight (lb) 184 185 240 242 262 300 327 Compressor Type Scroll REFRIGERANT Freon ® (R --- 22) Control TXV (R --- 22 Hard Shutoff) Char...
Page 4 - ACCESSORY THERMOSTATS; ACCESSORIES
4 ACCESSORY THERMOSTATS THERMOSTAT / SUBBASE PKG. DESCRIPTION TSTATBBPRH01 --- B* Thermidistat t Control — Non --- Programmable/Programmable Thermostat with Humidity Control (For use in Dual Fuel, AC, HP, and 2S applications. Includes Out- door Air Temperature Sensor.) TSTATBBPHH01 --- B* HybridHeat...
Page 5 - ACCESSORY USAGE GUIDELINE; Accessory Description and Usage (Listed Alphabetically); Compressor Start Assist — PTC Type
5 ACCESSORY USAGE GUIDELINE Accessory REQUIRED FOR LOW --- AMBI- ENT APPLICATIONS (Below 55 ° F) REQUIRED FOR LONG LINE APPLICATIONS* (Over 80 Ft.) REQUIRED FOR SEA COAST APPLICATIONS (Within 2 miles) Crankcase Heater Yes Yes No Evaporator Freeze Thermostat Yes No No Accumulator No No No Compressor ...
Page 7 - ELECTRICAL DATA
7 ELECTRICAL DATA (VOLTAGE) UNIT SIZE --- SERIES V/PH OPER VOLTS* COMPR FAN MCA MIN WIRE SIZE { MIN WIRE SIZE { MAX LENGTH (FT) } MAX LENGTH (FT) } MAX FUSE** or CKT BRK AMPS MAX MIN LRA RLA FLA 60 ° C 75 ° C 60 ° C 75 ° C (N) 018 --- A 208/230/1 253 187 41 9.0 0.5 11.70 14 14 166 158 20 (N) 024 ---...
Page 8 - NOTE
8 DI MENS IO NS NOTE : O pt iona l“ G ” de ns e coi lgua rd show n. 213R
Page 9 - OUTDOOR
9 213RN( A, G) BALANCE POI N T W ORKSHEET 0. 00 10. 00 20. 00 30. 00 40. 00 50. 00 60. 00 70. 00 80. 00 --1 0 0 10 203 04 05 0 607 08 0 OUTDOOR TEMPERA T URE, ºF BUILDI NG HEA TL OSS,UNI TINTEGRA TED HEA TI NG CAP ACI TY ,M BTUH 0. 0 2. 9 5. 9 8. 8 11 .7 14. 6 17. 6 20. 5 23. 4 kW 213R N (A, G )024A...
Page 10 - COMBINATION RATINGS
10 COMBINATION RATINGS Unit Size --- Series Indoor Model Cooling Capacity ARI Standard Ratings Cooling Heating Furnace Model Factory Enhance Standard Rating SEER TDR EER High Temp Low Temp HSPF E Capacity E COP H Capacity H COP 018 --- A *FA4CN(F,C)018 17,100 TDR&TXV 13.00 10.80 18,000 3.52 10,5...
Page 18 - DETAILED COOLING CAPACITIES
18 DETAILED COOLING CAPACITIES EVAPORATOR AIR CONDENSER ENTERING AIR TEMPERATURES deg F 75 85 95 105 115 125 CFM EW B Capacity MBtuh† Total Sys- tem KW** Capacity MBtuh† Total Sys- tem KW** Capacity MBtuh† Total Sys- tem KW** Capacity MBtuh† Total Sys- tem KW** Capacity MBtuh† Total Sys- tem KW** Ca...
Page 25 - HEAT PUMP HEATING PERFORMANCE
25 HEAT PUMP HEATING PERFORMANCE INDOOR AIR OUTDOOR COIL ENTERING AIR TEMPERATURES deg F --- 3 7 17 27 37 47 57 67 EDB CFM Capacity MBtuh Total Sys- tem KW† Capacity MBtuh Total Sys- tem KW† Capacity MBtuh Total Sys- tem KW† Capacity MBtuh Total Sys- tem KW† Capacity MBtuh Total Sys- tem KW† Capacit...
Page 26 - HEAT PUMP HEATING PERFORMANCE -- CONTINUED
26 HEAT PUMP HEATING PERFORMANCE -- CONTINUED INDOOR AIR OUTDOOR COIL ENTERING AIR TEMPERATURES deg F --- 3 7 17 27 37 47 57 67 EDB CFM Capacity MBtuh Total Sys- tem KW† Capacity MBtuh Total Sys- tem KW† Capacity MBtuh Total Sys- tem KW† Capacity MBtuh Total Sys- tem KW† Capacity MBtuh Total Sys- te...