NL917IB e5*72/245*95/54*0110*00 1-800-THE LIFT™ BRAUNLIFT.COM™ The Braun Corporation DOT Public Use Lift MODEL# Max. Lifting Capacity - 800 lbs. PATENT PENDING- 5,261,779-6,065,924-6,238,169-6,46 4,447-6,599,079-6,692,217-6,739,824 MFG DATE 56 14CG PUMP CODE CYLINDER 05-00025 SERIAL NUMBER 06/19/06 ...
Page 3 - Contents
Page 1 Contents Troubleshooting and Maintenance Lift Terminology ............................................................ 2 Switch and Sensor Locations ..................................... 3 Certi fi cation Checklist Diagnostic Procedures ......... 4 Platform Fold Pressure Adjustment .............
Page 4 - Outboard; Platform; Left; Lift Terminology
Page 2 UP DOWN 328 19 FOLD UNF OLD 328 20 ® Hand-Held Pendant Control Top Parallel Arms (2) Adjustable Quiet-Ride Stow Blocks (2) Main Cylinders (2) Vertical Arm Covers (4) Opposite Pump Side Vertical Arm Handrails (2) Outer Barrier Cylinder (not visible -underside of platform) Outer Barrier (Automa...
Page 5 - Switch and Sensor Locations
Page 3 Switch and Sensor Locations * Bridging Microswitch 31010FA Pressure Switch31199 Threshold Strip Switch31221A (Qty. 2) Outer Barrier RaisedMagnetic Sensor 32645NA60 Outer Barrier LatchedMagnetic Sensor 32645NA60 Outer Barrier RaisedMagnet31664 Outer Barrier LatchedMagnet31664 *Note: Mirror ima...
Page 6 - fl; Certification Checklist Diagnostic Procedures
Page 4 The following operations and conditions must be functionally veri fi ed in order for the lift to be FMVSS 403/404 compliant. If an operation does not function as described or a condition is not met, follow the refer-enced procedures to correct the problem or contact a Braun Corporation Produc...
Page 7 - Platform Fold Pressure Adjustment; Secure adjustment
Page 5 1. Lower the platform to the ground level loading position. 2. Remove the pump cover. 3. Turn the adjustment screw (shown below) counter clockwise until the outer barrier does not raise when the Up button is pressed. 4. Turn the adjustment screw clockwise in 1/4 turn increments until the oute...
Page 8 - Platform Angle Adjustment; equals; Figure C; must
Page 6 Platform Angle Adjustment Wedges Angle A equals Angle B . ✓ B Figure C A Approximately 1” Clearance Figure D Millennium “NL” Series Century “NCL” Series Vista “NVL” Series Inboard Outboard Inboard Outboard Wedges Toe must angle down slightly . Barrier must unfold fully . Adjusting the platfor...
Page 9 - Must make full contact; Gap; not permitted; stop blocks; with; Right; ensure both
Page 7 Platform Angle Adjustment Screws Adjustment Screw Allen Head A B Platform Angle Adjustment Adjustment Allen screws are provided on each side of the lift platform for adjusting the platform angle. Adjust platform angle as speci fi ed on previous page. Platform Stop Blocks Must make full contac...
Page 10 - Platform Floor Level Adjustment; LCD Screen; Floor Level Adjustment:
Page 8 Platform Floor Level Adjustment Diagnostics: Diagnostic codes have been established in event the lift platform fl oor position does not set (the lift does not sound three “beeps” - see Step 5 above). The control board located inside the pump hous- 91 – The platform position is out of a prede-...
Page 11 - Bridging Microswitch Adjustment
Page 9 H G Platform Stop Block Inboard Vertical Edge of Vertical Arm Bridging Microswitch Adjustment Screw Bridging Microswitch Adjustment Bridging Microswitch: The bridging microswitch is located at the bottom of the right (front) vertical arm. See Photos A and B. An adjust-ment screw is built into...
Page 12 - LCD Lift Codes
Page 10 To better understand the Braun LCD Trouble shooting display you must fi rst understand the numbers that appear on the screen. There are Flashing Codes, Solid Error Codes, and Solid Normal Operational Codes. Flashing Codes #65-89: About 10 seconds after an operation has stopped there are a se...
Page 13 - Flashing
Page 11 57 – Outer barrier is not up and latched and ground detect switch did not deactivate (Century and Vista only) 58 – Outer barrier is not up and latched and the plat- form is 3” above the ground 59 – Outer barrier is not up after pausing platform travel 60 – The kickout gas springs are worn, r...
Page 14 - Maintenance and Lubrication; Lubrication Diagram
Page 12 UP DO WN 328 19 FOL D UNF OLD 3282 0 ® Speci fi ed (recommended) Available Braun Lubricant Type Lubricant Amount Part No. LO - Light Oil LG - Light Grease Light Grease Lubriplate 14 oz. (Multipurpose) Can Light Penetrating Oil LPS2, General Purpose 11 oz. (30 weight or equivalent) Penetratin...
Page 15 - Maintenance and Lubrication Schedule; ed by an; Cycles; WARNING
Page 13 Maintenance and Lubrication Schedule Maintenance and lubrication procedures must be performed as speci fi ed by an authorized service technician. Failure to do so may result in serious bodily injury and/or property damage. Proper maintenance is necessary to ensure safe, troublefree operation...
Page 16 - Perform all procedures listed in previous section also
Page 14 Inspect lift for wear, damage or any abnormal condition Inspect lift for rattles Correct as needed. Correct as needed. Platform pivot pin bearings (2) Platform fold axles (2) Inner roll stop ( IB ) lever bearings (2) Inner roll stop ( IB ) lever slot (2) Rotating pivot slide arm pivot pins (...
Page 17 - Consecutive
Page 15 Resecure, replace or correct as needed. Remove pump module cover and inspect: • Hydraulic hoses, fi ttings and connections for wear or leaks • Harness cables, wires, terminals and connections for securement or damage • Control board, circuit breaker, power switch and lights for securement or...
Page 18 - NOTES
Page 16 NOTES This page intentionally left blank to provide a place for notes and references.
Page 19 - Lift Electrical Schematic; LIFT SHOWN IN STOWED POSITION; SWITCH BOX
Page 17 Lift Electrical Schematic NL917-05-025.ai BK(6) BK(4) GN(20) BU / WH(20) BU / WH(20) RD / WH(20) RD / WH(20) BU / BK(20) RD / BK(20) GN / WH(20) GN / WH(20) BU(20) GN(20) GN(20) GN(20) PK(20) OR(20) OR(20) GN(20) GN(20) GN(20) GN(20) GN(20) GN(14) BK(20) UP/FOLD SOLENOID IN-LINE FUSE RD (2) ...
Page 20 - Lift Wiring Diagram
Page 18 Unfold for: Lift Electrical Schematic Lift Wiring Diagram Platform Lights (Option) Circuit Sentry (Circuit Breaker) Bat. Aux. Lift Power Cable 205-0712-37 Pump Module Power Feed 26082A-4 Connects to Vehicle Battery (+) Positive Post Lead Wire 13362A GN(20) BK(20) BK(20) BK(20) BK(20) BK(20) ...
Page 21 - Hydraulic Schematic; Description
Page 19 Hydraulic Schematic Outer Barrier Cylinder Orifice Pump Side Cylinder BACKUP PUMP 2500 PSI Secondary Valve Folding Relief Valve Lifting Relief Valve Down Valve 1900 PSI PUMP Opposite Pump Cylinder M Orifice Bridging Valve 800PSI .50 GPM Roll Stop Fold Pressure Switch Fixed Displacement Pump ...
Page 22 - Hydraulics Parts List; * Raw material items ordered and priced per inch (order speci; Item; Part Numbers of Items Dedicated per Lift Model; Part Numbers of Items Identical on all Lift Models; do; with Dextron III or
Page 20 Hydraulics Parts List ✓ Seal Kits: If repairing a cylinder, order Seal Kit #1500-0500 P . * Raw material items ordered and priced per inch (order speci fi ed length). 16 Cartridge #26078 13 “Down and Bridge” Valve (complete) 14 Cartridge #24612 13 “Duel Relief” Valve (complete) 12 Coil #3112...
Page 23 - Hydraulics Diagram; Pump Side Cylinder
Page 21 Hydraulics Diagram Pump Side Cylinder Opposite Pump Side Cylinder Hydraulic Pump Manual Backup Pump 27 1 2 33 20 18 21 27 3 3 26 25 25 23 30 29 22 29 4 5 19 28 29 12 11 24 15 Roll Stop Cylinder 31 6 32 28 17 7 36 10 8 9 34 35 FRONT PUMP FRONT PUMP REAR PUMP Hydraulic Repair For repair of ahy...
Page 24 - Apply red #271 Thread Locker Loctite; only; included with replacement pump
Page 22 Pump Module Parts List * Apply red #271 Thread Locker Loctite ® to the four hex bolts (items 27 and 28) if a blue nylon patch is not present on the bolts when retro fi tting an M268-0113 pump assembly. Loctite ® is available from The Braun Corporation under part number 11522-1. t Indicates i...
Page 25 - Pump Mounting Bolts; Apply red #271 Thread Locker Locktite
Page 23 Pump Module Diagram Pump Mounting Bolts Apply red #271 Thread Locker Locktite ® to the three pump mounting bolts (items 27 and 28) if a blue nylon patch is not present on the bolts when retro fi tting an M268 pump assembly. Loctite ® is available from The Braun Corporation under part number ...
Page 26 - 2” Floor-to-Ground Lift Repair Parts List; Part Numbers of Items Identical on All Lift Models
Page 24 42” Floor-to-Ground Lift Repair Parts List 1 1 Base Weldment 915R5142NW30 915F5142NW30 918R5142NW33 918F5142NW33 2 1 Cover, Pump, 2-Piece, Back-Bottom 915-0513RNPT 915-0513FNPT 915-0513RNPT 915-0513FNPT 3 1 Cover, Pump, 2-Piece, Top-Front Assy. 915-0519RNPT 915-0519FNPT 915-0519RNPT 915-0519...
Page 29 - 8” Floor-to-Ground Lift Repair Parts List
Page 27 48” Floor-to-Ground Lift Repair Parts List Part Numbers of Items Identical on All Lift Models 1 1 Base Weldment 985R5148NW30 985F5148NW30 985R5148NW33 985F5148NW33 985R5148NW34 985F5148NW34 2 1 Cover, Pump, 2-Piece, Back-Bottom 915-0513RNPT 915-0513FNPT 915-0513RNPT 915-0513FNPT 915-0513RNPT...
Page 31 - Dealers Worldwide
Over 300 Braun Dealers Worldwide "Providing Access to the World" ® "Providing Access to the World" International Corporate Hdqrs: P.O. Box 310 Winamac, IN 46996 USA 1-800-THE LIFT ® (574) 946-6153 FAX: (574) 946-4670 ®
Page 32 - Millennium; Braun Corporation Product Support Department. Call 1-800-THE LIFT; Return Authorization Procedure; Series; Braun
HZg^Zh HZg^Zh Millennium CA CA Public UseWheelchair Lifts Patent #5,261,779 Patent #6,065,924 Patent #6,238,169 Patent #5,261,779 Patent #6,065,924 Patent #6,238,169 Patent #6,464,447 Patent #6,599,079 Patent #6,692,217 Patent #6,464,447 Patent #6,599,079 Patent #6,692,217 Patent #6,739,824 Patents ...