Page 3 - Table of Contents; Hazard; Information To Be Used Only By Qualifi ed Service Technicians; General
RWB 6104 BAFII R01 Page 3 Table of Contents General Information Hazard Defi nitions ........................................................................................................................................ 4 Owner’s Responsibility .........................................................
Page 4 - Within the boundaries of the hazard warning,; NOTICE; immediately contact; Owner’s Responsibility; carbon monoxide poisoning, soot or explosion.; Hazard Defi nitions; Indicates an imminently haz-; DANGER; Indicates a potentially; WARNING; CAUTION; Professional Service; WARNING
Page 4 RWB 6104 BAFII R01 General Information General Information Within the boundaries of the hazard warning, there will be information presented describing consequences if the warning is not heeded and instructions on how to avoid the hazard. NOTICE Intended to bring special attention to informati...
Page 5 - Notice Special Requirements; For recommended installation practice in Canada,; Inspect/Prepare Installation Site; Clearances to Burner and Appliance; Provide space around burner and appliance for; General Information; HB 6 slot
RWB 6104 BAFII R01 Page 5 General Specifi cation Table 1 – Burner Specifi cations Capacity ‘HLX’ HeadsFiring rate: - 0.40 – 1.50 GPH Input: Min./Max - 56,000 /210,000 Btu/h ‘FBX’ HeadsFiring rate: - 0.40 – 1.35 GPH Input: Min./Max. - 56,000/189,000 Btu/h Certifi cation/Approvals UL certifi ed to com...
Page 6 - Inspect Chimney or Direct Vent System; Appliances located in confi ned spaces:; Direct/Sidewall Venting Application; Failure to provide adequate air supply could se-; Adequate Combustion; Figure 2. Outside Air Connection; Figure 1. Burner label location
Page 6 RWB 6104 BAFII R01 Inspect/Prepare Installation Site Inspect Chimney or Direct Vent System Inspect the chimney or vent. Make sure it is properly sized and in good working condition. Follow the in-structions supplied by the appliance manufacturer. Combustion Air Supply Information • • See NFPA...
Page 7 - Damage to the pump could cause impaired burn-; Figure 3. – Mounting Burner in Appliance; Prepare the Burner
RWB 6104 BAFII R01 Page 7 Never use Tefl on tape on fuel oil fi ttings. Tape fragments can lodge in fuel line components and fuel unit, damaging the equipment and pre-venting proper operation.Use oil-resistant pipe sealant compounds. •• • Damage to the pump could cause impaired burn- er operation, o...
Page 8 - Connect Fuel Lines; Failure to follow these instructions; Explosion and Fire Hazard; Start the Burner and Set Combustion; Startup burner; cannot; Damage to the fi lter or pump seals could cause; Failure to comply could cause immediate pump; Do Not Install By-pass Plug; Wiring Connections Diagram
Page 8 RWB 6104 BAFII R01 The burner is supplied with either a one-stage pump or a two-stage pump based on the oil supply system requirements. Consult the instructions pro-vided with the pump for installation specifi cations. Connect Fuel Lines • Start the Burner and Set Combustion Do not attempt to...
Page 9 - Figure 4. – Typical Wiring, R7184 Primary Control; Control System Features
RWB 6104 BAFII R01 Page 9 Start the Burner and Set Combustion Figure 4. – Typical Wiring, R7184 Primary Control SK9359 7. RECYCLE. If the fl ame is lost while the burner is fi ring, the control shuts down the burner, enters a 60 second recycle delay, and then repeats the above ignition sequence. If ...
Page 10 - Set combustion with instruments; Natural Draft Applications; Trained Service Technician’s Regular; Tampering with or making incorrect; Annual Professional Ser-; Trained Service Technician’s Regular Maintenance
Page 10 RWB 6104 BAFII R01 If the burner locks out on safety during bleed-ing, reset the safety switch and complete the bleeding procedure. Note — Electronic safety switches can be reset immediately; others may require a three- to fi ve-minute wait.If burner stops after fl ame is established, addi-t...
Page 11 - Perform the following steps when replacing a noz-; Incorrect nozzles and fl ow rates; Correct Nozzle and Flow; and potential fi re or asphyxiation hazards.; Nozzle Flow Rate by Size
RWB 6104 BAFII R01 Page 11 If motor is not permanently lubricated, oil motor with a few drops of SAE 20 nondetergent oil at each oil hole. DO NOT over oil motor. Exces-sive oiling can cause motor failure.Check motor current. The amp draw should not exceed the nameplate rating by more than 10%.Check ...
Page 12 - To install a new nozzle, place a; Check/Adjust Electrodes; Check the electrode tip settings, as shown in Figure; Figure 5a. HLX Air Tube; placement; For installation or re-; binations
Page 12 RWB 6104 BAFII R01 Inspect the nozzle adapter before installing the new nozzle. If it is grooved or scratched on the sealing surface, replace the nozzle line assem-bly. If the surface is damaged, oil could leak at the nozzle to adapter joint, causing serious com-bustion problems. Protect the...
Page 13 - HLX Firing Rate; HLX Air Dial Setting; FBX Firing Rate
RWB 6104 BAFII R01 Page 13 Stop Screw AFII 85 AFII 100 AFII 150 0 0.40-0.65 0.5-0.65 0.75-1.00 1 - 0.6-0.75 0.85-1.10 2 - 0.65-0.80 0.95-1.15 3 0.60-0.75 0.65-0.90 0.95-1.20 4 - 0.75-0.95 1.10-1.25 5 0.70-0.85 0.85-1.00 1.15-1.35 6 - 0.95-1.10 1.15-1.40 7 - - 1.25-1.50 8 - - 1.30-1.50 HLX Firing Rat...
Page 14 - For best performance specify genuine; replacement parts; Replacement Parts Diagram
Page 14 RWB 6104 BAFII R01 For best performance specify genuine Beckett replacement parts Replacement Parts Diagram Beckett 10 8 21 11 16 17 6 18 14 7 4 20 22 9 5 15 2 13 23 3 19 12 1 SK8265B
Page 15 - Replacement Parts List
RWB 6104 BAFII R01 Page 15 Item Description Kit No. 1 Air tube combination Specify 2 Blower Wheel: AFII 85 (4-1/4”) AFII 100 (4-1/2”) AFII 150 (4-1/2”) 21439U 21438U 21438U 3 Electrical box 30613BK 4 Connector tube, 8” Copper 5394U 5 Coupling, Motor to Pump 21437U 6 Electrodes: HLX Heads FBX Heads 5...
Page 16 - Limited; WARRANTY; For Residential, Commercial and Specialty Burners; BECKETT; CORPORATION; Limited Warranty Information
Page 16 RWB 6104 BAFII R01 Limited WARRANTY For Residential, Commercial and Specialty Burners The R. W. BECKETT CORPORATION (“Beckett”) warrants to persons who purchase its Beckett burners from Beckett for resale or for incorporation into a product for resale (“Customers”) that its equipment is free...