Page 2 - Bryan Steam; DR
Bryan Steam DR Series Boiler Boiler Burner Chassis Spec. Air Tube Combination High Fire Rate Nozzle Head Setting Blue - Low Fire Air or Shutter Red - High Fire Air or Band Low Fire Pump Press. High Fire Pump Press. Pressure Firing Flange Insertion 250 CF375 BCF3907 CF56KZ 1.79 1.50x60ES 1 10 1/2 N/A...
Page 3 - Buderus; Buderus
Buderus G215 Series Boiler Boiler Burner Chassis Spec. Air Tube Combination High Fire Rate Nozzle Head Setting Blue - Low Fire Air or Shutter Red - High Fire Air or Band Low Fire Pump Press. High Fire Pump Press. Pressure Firing Flange Insertion 3 AFG B2007 AFG50ML 1.10 0.90x45ES 0 8 1 N/A 170 51311...
Page 5 - Burnham Corporation; FD
Burnham Corporation E Series Boiler Boiler Burner Chassis Spec. Air Tube Combination High Fire Rate Nozzle Head Setting Blue - Low Fire Air or Shutter Red - High Fire Air or Band Low Fire Pump Press. High Fire Pump Press. Pressure Firing Flange Insertion E20 CF800 BCF403 CF80KJ 6.00 5.00x60SS 2 10 5...
Page 6 - FDO
Burnham Corporation FDO Series Boiler Boiler Burner Chassis Spec. Air Tube Combination High Fire Rate Nozzle Head Setting Blue - Low Fire Air or Shutter Red - High Fire Air or Band Low Fire Pump Press. High Fire Pump Press. Pressure Firing Flange Insertion FDO-7 CF500 BCF809 CF60KK 2.25 2.00x45P 1 3...
Page 7 - MPC
Burnham Corporation MPC Series Boiler Boiler Burner Chassis Spec. Air Tube Combination High Fire Rate Nozzle Head Setting Blue - Low Fire Air or Shutter Red - High Fire Air or Band Low Fire Pump Press. High Fire Pump Press. Pressure Firing Flange Insertion MPC-4 CF500 BCF809 CF66KK 3.55 02.75x70B D ...
Page 11 - CT; Columbia Boiler; CWH
Columbia Boiler CT Series Boiler Boiler Burner Chassis Spec. Air Tube Combination High Fire Rate Nozzle Head Setting Blue - Low Fire Air or Shutter Red - High Fire Air or Band Low Fire Pump Press. High Fire Pump Press. Pressure Firing Flange Insertion CT-20 CF800 BCF403 CF100KJ 6.00 5.00x60P 3 7 0 N...
Page 12 - HRT; WL
Columbia Boiler HRT Series Boiler Boiler Burner Chassis Spec. Air Tube Combination High Fire Rate Nozzle Head Setting Blue - Low Fire Air or Shutter Red - High Fire Air or Band Low Fire Pump Press. High Fire Pump Press. Pressure Firing Flange Insertion HRT-20 CF800 BCF403 CF100KJ 6.00 5.00x60P 3 7 0...
Page 13 - Crown Boiler; Crown Boiler; FW
Crown Boiler CT Series Boiler Boiler Burner Chassis Spec. Air Tube Combination High Fire Rate Nozzle Head Setting Blue - Low Fire Air or Shutter Red - High Fire Air or Band Low Fire Pump Press. High Fire Pump Press. Pressure Firing Flange Insertion CT6 SMG B1403 SMG45NR 1.65 1.35x45ES 0 7 1 N/A 150 ...
Page 14 - VH
Crown Boiler VH Series Boiler Boiler Burner Chassis Spec. Air Tube Combination High Fire Rate Nozzle Head Setting Blue - Low Fire Air or Shutter Red - High Fire Air or Band Low Fire Pump Press. High Fire Pump Press. Pressure Firing Flange Insertion VH8 CF2300A BCF304 CF66KG 10.20 6.00x45P 0 16 30 12...
Page 15 - DeDietrich; Dunkirk; DPFO
DeDietrich GT210 Series Boiler Boiler Burner Chassis Spec. Air Tube Combination High Fire Rate Nozzle Head Setting Blue - Low Fire Air or Shutter Red - High Fire Air or Band Low Fire Pump Press. High Fire Pump Press. Pressure Firing Flange Insertion 214A AFG B2007 AFG50MLSS 1.20 1.00x60B 1 10 1 N/A ...
Page 16 - ESP; Easco Boiler; FST
Easco Boiler ESP Series Boiler Boiler Burner Chassis Spec. Air Tube Combination High Fire Rate Nozzle Head Setting Blue - Low Fire Air or Shutter Red - High Fire Air or Band Low Fire Pump Press. High Fire Pump Press. Pressure Firing Flange Insertion 70 CF2500 BCF1801 CF102KP 21.00 6.00x45P (2) 5 10 ...
Page 17 - PLW
Easco Boiler PLW Series Boiler Boiler Burner Chassis Spec. Air Tube Combination High Fire Rate Nozzle Head Setting Blue - Low Fire Air or Shutter Red - High Fire Air or Band Low Fire Pump Press. High Fire Pump Press. Pressure Firing Flange Insertion 53 CF2300A BCF304 CF102KG 16.00 9.50x45P 5 30 60 1...
Page 19 - Hurst; Cyclone
Hurst Cyclone Series Boiler Boiler Burner Chassis Spec. Air Tube Combination High Fire Rate Nozzle Head Setting Blue - Low Fire Air or Shutter Red - High Fire Air or Band Low Fire Pump Press. High Fire Pump Press. Pressure Firing Flange Insertion 6HP CF500 BCF809 CF100KK 2.00 1.75x60B (D) 0 2 0 N/A ...
Page 20 - National Combustion
National Combustion CO-XC Series Boiler Boiler Burner Chassis Spec. Air Tube Combination High Fire Rate Nozzle Head Setting Blue - Low Fire Air or Shutter Red - High Fire Air or Band Low Fire Pump Press. High Fire Pump Press. Pressure Firing Flange Insertion 58 CF800 BCF403 CF60KH 4.50 4.00x45P 3 10...
Page 21 - Peerless Boiler
Peerless Boiler 7FDA Series Boiler Boiler Burner Chassis Spec. Air Tube Combination High Fire Rate Nozzle Head Setting Blue - Low Fire Air or Shutter Red - High Fire Air or Band Low Fire Pump Press. High Fire Pump Press. Pressure Firing Flange Insertion 704 CF800 BCF403 CF60KH 3.95 3.50x70B 0 40 10 ...
Page 23 - LC; LCE
Peerless Boiler LC Series Boiler Boiler Burner Chassis Spec. Air Tube Combination High Fire Rate Nozzle Head Setting Blue - Low Fire Air or Shutter Red - High Fire Air or Band Low Fire Pump Press. High Fire Pump Press. Pressure Firing Flange Insertion LC04 CF800 BCF403 CF60KH 4.75 4.00x45P 2 0 9 N/A...
Page 24 - SC; TC
Peerless Boiler SC Series Boiler Boiler Burner Chassis Spec. Air Tube Combination High Fire Rate Nozzle Head Setting Blue - Low Fire Air or Shutter Red - High Fire Air or Band Low Fire Pump Press. High Fire Pump Press. Pressure Firing Flange Insertion SC05 CF500 BCF809 CF60KK 3.00 2.50x60B 2 7 1 N/A...
Page 25 - Liberty
Slant/Fin Liberty Series Boiler Boiler Burner Chassis Spec. Air Tube Combination High Fire Rate Nozzle Head Setting Blue - Low Fire Air or Shutter Red - High Fire Air or Band Low Fire Pump Press. High Fire Pump Press. Pressure Firing Flange Insertion LD-60 CF375 BCF3907 CF56KZ 2.60 2.25x45P 1 10 3 N...
Page 26 - Smith Cast Iron Boilers
Smith Cast Iron Boilers 18 Series Boiler Boiler Burner Chassis Spec. Air Tube Combination High Fire Rate Nozzle Head Setting Blue - Low Fire Air or Shutter Red - High Fire Air or Band Low Fire Pump Press. High Fire Pump Press. Pressure Firing Flange Insertion 18-4 CF500 BCF809 CF60KK 2.55 2.25x60PLP...
Page 29 - Utica Boiler; Starfire II
Smith Cast Iron Boilers HE28 Series Boiler Boiler Burner Chassis Spec. Air Tube Combination High Fire Rate Nozzle Head Setting Blue - Low Fire Air or Shutter Red - High Fire Air or Band Low Fire Pump Press. High Fire Pump Press. Pressure Firing Flange Insertion HE28-4 CF1400 BCF205 CF66KF 7.80 4.50x...
Page 30 - Vaillant Corporation
Vaillant Corporation F200 Series Boiler Boiler Burner Chassis Spec. Air Tube Combination High Fire Rate Nozzle Head Setting Blue - Low Fire Air or Shutter Red - High Fire Air or Band Low Fire Pump Press. High Fire Pump Press. Pressure Firing Flange Insertion F200-5 CF500 BCF809 CF80KK 2.25 2.00x45AS...
Page 31 - Weil McLain
Weil McLain 76 Series Boiler Boiler Burner Chassis Spec. Air Tube Combination High Fire Rate Nozzle Head Setting Blue - Low Fire Air or Shutter Red - High Fire Air or Band Low Fire Pump Press. High Fire Pump Press. Pressure Firing Flange Insertion 476 CF500 BCF809 CF60KK 2.35 2.00x45B 1 4 0 N/A 140 ...