Page 2 - Instruction Manual; – Model CF2300A Oil Burner
Instruction Manual – Model CF2300A Oil Burner 2 Form 6104 BCF-23-R0399 Please . . . read this page first D e n o t e s p r e s e n c e o f a h a z a r d w h i c h , i fignored, could result in minor personal injuryor property damage. Hazard definitions The following will be used throughout this manu...
Page 3 - Contents; Specifications; Cast aluminum; Agency approvals; Appliance manufacturer’s instructions
Instruction Manual – Model CF2300A Oil Burner 3 Form 6104 BCF-23-R0399 Warranty Beckett warrants its equipment to those whohave purchased it for resale, including yourdealer. If you have any problems with yourequipment or its installation, you shouldcontact your dealer for assistance. Refer to warra...
Page 4 - Pre-installation checklist; Table 1 – Nozzle capacities at various pressures; loop required for one-pipe fuel supply installations. See; When fuel supply is below the burner fuel unit —; Burner box; Pressure - pounds per square inch
Instruction Manual – Model CF2300A Oil Burner 4 Form 6104 BCF-23-R0399 Pre-installation checklist Table 1 – Nozzle capacities at various pressures ❏ Combustion air supply • The burner requires combustion air and ventilation air for reliable operation. Assure that the building and/or com-bustion air ...
Page 5 - Table 2 – Air tube capacity vs. firebox pressure; Figure 1 – Min. combustion chamber dimensions; Verify firing rate; Verify air tube
Instruction Manual – Model CF2300A Oil Burner 5 Form 6104 BCF-23-R0399 Table 2 – Air tube capacity vs. firebox pressure Figure 2 – Air tube mounting dimensions 2304 E D G T 2° 1 F E Insertion depth G Air tube to inside of chamber– 0.25" ± 0.125" T Air tube length D Tube diameter Figure 1 – M...
Page 6 - Mount the burner; Install nozzle line assembly; Figure 4 – Nozzle and nozzle line assembly
Instruction Manual – Model CF2300A Oil Burner 6 Form 6104 BCF-23-R0399 Mount the burner ❏ Mount flange(s) on air tube • This section does not apply to burners with welded flanges.• Do not install air tube on burner.• For non-pressure firing flange, refer to Figure 3 : Install gasket (item a ) and fl...
Page 7 - Figure 5 – Nozzle line assembly in burner; Set dimension Z; Figure 6 – Adjusting plate assy.; once again. Loosen acorn nut; do not loosen acorn nut; Insert burner; inches less than dimension; Figure 7 – Burner installed in appliance front; Legend
Instruction Manual – Model CF2300A Oil Burner 7 Form 6104 BCF-23-R0399 Figure 5 – Nozzle line assembly in burner ❏ ❏ ❏ ❏ ❏ Set dimension Z • Replace the rear access door on the burner, making sure that the adjust-ing plate assembly is now securelyheld in place. • Loosen acorn nut d in Figure 5 . Sli...
Page 8 - Do not remove the by-pass plug; ” pump; Oil supply/return lines
Instruction Manual – Model CF2300A Oil Burner 8 Form 6104 BCF-23-R0399 Connect fuel line(s) ❏ Fuel unit by-pass plug • The CF2300A burner is shipped with a by-pass plug in- stalled in the fuel unit. For low/high operation, the by- pass plug must be left in the fuel unit , regardless of the fuel syst...
Page 9 - Burner fuel flow; fuel units, the by-passing is done inside the; Figure 9c – Two-pipe oil flow with “; Gearset capacity
Instruction Manual – Model CF2300A Oil Burner 9 Form 6104 BCF-23-R0399 Figure 9a – Two-pipe oil flow, low fire, “ H ” pump • Use continuous lengths of heavy-wall copper tubing, routed under the floor where possible. Do not attach fuellines to the appliance or to floor joists if possible. Thisreduces...
Page 10 - Wire the burner; NOTE: The wiring in; Figure 10 – Typical wiring; PR
Instruction Manual – Model CF2300A Oil Burner 10 Form 6104 BCF-23-R0399 Legend FD Fused disconnect, by others L M Limit controls, by others O P Operating controls, by others P R Oil primary control, R8184 typical CC Flame sensor, cad cell typical TM Optional delay timer TR Ignition transformer M1 Bu...
Page 11 - Sequence of operation — typical; the damper has reached full open
Instruction Manual – Model CF2300A Oil Burner 11 Form 6104 BCF-23-R0399 Sequence of operation — typical NOTE: The following sequence is based on using a type B fuel unit, with pump-mounted by-pass valve. The by-pass valveoperation is reversed for a type H fuel unit. That is, the by- pass valve is po...
Page 12 - Prepare the burner for start-up; IN; Figure 11 – Adjusting plate initial setting, typical; Approximate
Instruction Manual – Model CF2300A Oil Burner 12 Form 6104 BCF-23-R0399 Prepare the burner for start-up - continued ❏ Z dimension • Should be set per these instructions (see page 7). The top acorn nut ( Figure 11 , item d ) should never be loosened once the Z dimension is initially set. ❏ Adjusting ...
Page 13 - Table 5 – Initial air adjusting plate settings; Figure 12 – Air damper and damper motor assembly
Instruction Manual – Model CF2300A Oil Burner 13 Form 6104 BCF-23-R0399 Table 5 – Initial air adjusting plate settings (damper position) CLOSE OPEN 2309-1 a b d e f g Figure 12 – Air damper and damper motor assembly CLOSE 12 0 1 2 3 4 5 6 7 8 9 10 11 2309-2 a h b d c k m Legend (Figure 12) a Damper ...
Page 14 - Start the burner; Start burner and vent air from oil line; fire in; OUT
Instruction Manual – Model CF2300A Oil Burner 14 Form 6104 BCF-23-R0399 Start the burner Do not proceed unless all prior steps in thismanual have been completed. Failure tocomply could result in severe personal injury,death or substantial property damage. Do not attempt to start the burner when exce...
Page 15 - Maintenance and service; Annual service; Monthly maintenance
Instruction Manual – Model CF2300A Oil Burner 15 Form 6104 BCF-23-R0399 Maintenance and service Annual service — by qualified service technician Have the burner inspected, tested and started at least annuallyby a qualified service technician. This annual test/inspectionshould include at least the fo...
Page 16 - Replacement parts; Figure 13 – Adjustable mounting plates for CF2300A
Instruction Manual – Model CF2300A Oil Burner Form 6104 BCF-23-R0399 U.S.A.: P. O. Box 1289 • Elyria, Ohio 44036 • 800-645-2876 • 440-327-1060 • FAX 440-327-1064 Canada: R. W. Beckett Canada, Ltd. • 430 Laird Road • Guelph, Ontario, N1G 3X7 • 800-665-6972 • FAX 519-763-5656 SUNTEC 1 2 3 4 5 12 13 14...