Page 4 - TABLE OF CONTENTS; CHAPTER 1
50-Port Dual Web Rack Switch ii TABLE OF CONTENTS CHAPTER 1 ............................................... 1 1.1 A BOUT T HIS G UIDE ........................................................................................................................ 1 1.2 T ERMS /U SAGE ...........................
Page 5 - APPENDIX A; APPENDIX B; APPENDIX C
50-Port Dual Web Rack Switch iii Reset Settings ................................................................................................................................. 23 Logout ...................................................................................................................
Page 7 - Chapter 1; Introduction; About This Guide; Gigabit Ethernet Technology
50-Port Dual Web Rack Switch 1 Chapter 1 Introduction 1.1 About This Guide Congratulations on your purchase of the 48+4G-Port 10/100/1000Mbps Gigabit Ethernet Web Smart Switch. This device integrates 1000Mbps Gigabit Ethernet, 100Mbps Fast Ethernet and 10Mbps Ethernet network capabilities in a highl...
Page 8 - Fast Ethernet Technology
50-Port Dual Web Rack Switch 2 internetworking technologies. And with expected advances in the coming years in silicon technology and digital signal processing that will enable Gigabit Ethernet to eventually operate over unshielded twisted-pair (UTP) cabling, outfitting your network with a powerful ...
Page 9 - QoS
50-Port Dual Web Rack Switch 3 QoS QoS gives you full control over which types of outgoing data traffic should be given priority by the Switch, ensuring important data like gaming packets move through the Switch at lightning speed, even under heavy load. 1.4 Features Dual Web Rack Switch provides th...
Page 10 - Chapter 2; Installation; Package Contents
50-Port Dual Web Rack Switch 4 Chapter 2 Installation This chapter provides unpacking and installation information for the Switch. 2.1 Package Contents Open the shipping cartons of the Switch and carefully unpacks its contents. The carton should contain the following items: • 50-Port Dual Web Rack S...
Page 11 - Connecting Network Cable
50-Port Dual Web Rack Switch 5 Combine the Switch with the provided screws Then, use screws provided with the equipment rack to mount each switch in the rack. Mount the Switch in the rack 2.4 Connecting Network Cable The Switch supports 10Mbps Ethernet or 100Mbps Fast Ethernet and it runs both in ha...
Page 12 - Identifying External Components; Front Panel
50-Port Dual Web Rack Switch 6 2.5 AC Power The Switch used the AC power supply 100-240V AC, 50-60 Hz. The power switch is located at the rear of the unit adjacent to the AC power connector and the system fan. The switch’s power supply will adjust to the local power source automatically and may be t...
Page 13 - Rear Panel
50-Port Dual Web Rack Switch 7 The Switch is equipped with two Gigabit twisted pair ports, supported auto negotiable 10/100/1000Mbps and auto MDI/MDIX crossover detection function. These two ports can operate in half-duplex mode for 10/100Mbps and full- duplex mode for 10/100/1000Mbps. When the port...
Page 15 - Chapter 3; Configuration; Installing the Web Management Utility; Web Management Utility
50-Port Dual Web Rack Switch 9 Chapter 3 Configuration Through the Web Browser you can configure the Switch such as VLAN, Trunking, QoS… etc. With the attached Web Management Utility, you can easily discover all the Web Management Switch, assign the IP Address, changing the password and upgrading th...
Page 16 - Discovery List
50-Port Dual Web Rack Switch 10 Discovery List This is the list where you can discover all the Web management devices in the entire network. By pressing the “ Discovery ” button, you can list all the Web Management devices in the discovery list. Double click or press the “ Add to monitor list ” butt...
Page 17 - Monitor List
50-Port Dual Web Rack Switch 11 Monitor List All the Web Smart Device in the Monitor List can be monitored; you can also receive the trap and show the status of the device. System word definitions in the Monitor List: • S: Shows the system symbol of the Web-Smart device, represent for device system ...
Page 18 - Device Setting
50-Port Dual Web Rack Switch 12 In order to receive Trap information, switch has to be configured with Trap IP and Trap Events in Web browser, which are available in the Trap Setting Menu Add Item: To add a device to the Monitor List manually, enter the IP Address of the device that you want to moni...
Page 19 - Toolbar
50-Port Dual Web Rack Switch 13 Do NOT upgrade firmware on any Atlantis Land product over a wireless connection. Failure of the device may result. Use only hard-wired network connections. Web Access: Double click the device in the Monitor List or select a device in the Monitor List and press this “ ...
Page 20 - Chapter 4; WEB Configuration
50-Port Dual Web Rack Switch 14 Chapter 4 WEB Configuration The 48+4G-Port 10/100/1000Mbps Gigabit Ethernet Web Smart Switch has a Web GUI interface for smart switch configuration. The Switch can be configured through the Web Browser. A network administrator can manage, control and monitor the switc...
Page 21 - Port Settings
50-Port Dual Web Rack Switch 15 4.2 Setup Menu When the main page appears, find the Setup menu in the left side of the screen. Click on the setup item that you want to configure. There are 3 options: Port Settings, VLAN Settings, Trunk Setting. Port Settings In Port Settings menu, this page will sho...
Page 23 - VLAN Settings (Virtual Local Area Network)
50-Port Dual Web Rack Switch 17 QoS: In some ports that need to have a high priority to manage the data transfer, QoS should be change. Set the port’s QoS to high to determine the port will always transfer their data first. QoS function can be working in any port either from port 1 to port 24 or fro...
Page 24 - Trunk Setting
50-Port Dual Web Rack Switch 18 Once you want to modify the VLAN Group, check on the ID parameter, the ID VLAN configuration window will pop out. Group 1 and Group 2 can not be managed at the same time When add a new Vlan, the members of default Vlan 1 are removed automatically. Therefore, packets c...
Page 25 - Statistics
50-Port Dual Web Rack Switch 19 4.3 Maintenence Status Click on the “ Status ” to present the device status on this screen, it will show the System Status, Port Status, VLAN Status and Trunk Status . Press “ Refresh ” when you need to renew the posted information. Statistics The Statistic Menu scree...
Page 26 - System Settings
50-Port Dual Web Rack Switch 20 System Settings The System Setting includes the System name, Location name, Login Timeout, IP Address, Subnet Mask and Gateway. Through the Web Management Utility, you can easily recognize the device by using the System Name and the Location Name. The Login Timeout is...
Page 27 - TRAP
50-Port Dual Web Rack Switch 21 TRAP The Trap Setting enables the device to monitor the Trap through the Web Management Utility, set the Trap IP Address of the manager where the trap to be sent. System Events : Monitoring the system’s trap. • Device Bootup: a trap when booting up the system. • Illeg...
Page 28 - Set Password
50-Port Dual Web Rack Switch 22 • Abnormal* Transmit Error: a trap when there are transmit data error in copper port. • Abnormal*: 50 error packet count within 10 seconds. Abnormal*: 50 error packet count within 10 seconds. Set Password Password is the invaluable tool for the manager to secure Web M...
Page 29 - Reset Settings
50-Port Dual Web Rack Switch 23 Reset Settings The Factory Reset button helps you to reset the device back to the default setting from the factory. Be aware that the entire configuration will be reset, the IP address of the device will be set to default setting 192.168.0.1 [password= admin] . Logout...
Page 30 - RJ-45 Pin Specification
50-Port Dual Web Rack Switch 24 APPENDIX A RJ-45 Pin Specification The following diagram and tables show the standard RJ-45 receptacle/connector and their pin RJ-45 Connector pin assignment Contact Media Direct Interface Signal 1 TX + (tx) 2 TX - (tx) 3 Rx + (rx) 4 Not used 5 Not used 6 Rx - (rx) 7 ...
Page 31 - Technical Specifications
50-Port Dual Web Rack Switch 25 APPENDIX B Technical Specifications Standard IEEE 802.3 10BASE-T Ethernet IEEE 802.3u 100BASE-TX Fast Ethernet IEEE 802.3z 1000BASE-SX/LX Gigabit Ethernet IEEE 802.3ab 1000BASE-T Gigabit Ethernet IEEE 802.3x Full Duplex Flow Control Protocol CSMA/CD Data Transfer Rate...
Page 32 - Support
50-Port Dual Web Rack Switch 26 APPENDIX C Support If you have any problems with theSwitch , please consult this manual. If you continue to have problems you should contact the dealer where you bought this Switch. If you have any other questions you can contact the Atlantis Land company directly at ...