i Delivery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1Unpacking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1Safety Procedures and Precautions . . . . . . . . . . . . . 2 Installation Site Installation . . . . . . . . . . . . . . . . . . . . . . . . . . ...
Page 3 - d e l i v e r y; c a u t i o n; TO PREVENT PERSONAL INJURY,
CT ExpRESS INSTALLATION MANUAL • 1 . d e l i v e r y This alto-shaam appliance has been thoroughly tested and inspected to ensure only the highest quality unit is provided. upon receipt, check for any possible shipping damage and report it at once to the delivering carrier. see transportation damage...
Page 4 - This appliance is intended to cook, hold; n o t e
CT ExpRESS INSTALLATION MANUAL • 2 . c a u t i o n Used to indicate the presence of a hazard that can or will cause minor personal injury, property damage, or a potential unsafe practice if the warning included with this symbol is ignored. c a u t i o n Used to indicate the presence of a hazard that...
Page 5 - s i t e i n s t a l l a t i o n; i n s t a l l a t i o n; d a n g e r; v e n t i l a t i o n r e q u i r e m e n t s; s o u n d p r e s s u r e m e a s u r e m e n t
CT ExpRESS INSTALLATION MANUAL • 3 . s i t e i n s t a l l a t i o n i n s t a l l a t i o n d a n g e r IMPROPER INSTALLATION, ALTERATION, ADJUSTMENT, SERVICE, OR MAINTENANCE COULD RESULT IN SEVERE INJURY, DEATH, OR CAUSE PROPERTY DAMAGE.READ THE INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS...
Page 6 - positioning on site; Air supply vents are located; minimum clearance requirements; Additional clearance is needed for; To avoid equipment damage, observe
CT ExpRESS INSTALLATION MANUAL • 4 . n o t e : note dimensions required for doorways and aisles for access of the oven and pallet to the installation site. Transport the oven in an upright and level position only. do not tilt the oven. ® s i t e i n s t a l l a t i o n i n s t a l l a t i o n positi...
Page 7 - l i f t i n g i n s t r u c t i o n s
CT ExpRESS INSTALLATION MANUAL • 5 . l i f t i n g i n s t r u c t i o n s i n s t a l l a t i o n remove banding before lifting. lift the unit from either side of the unit, n e v e r f r o m t h e f r o n t o r b a c k . adjust the forks so that they do not damage any of the components under the un...
Page 8 - positioning requirements; Air supply vents are located at the bottom
CT ExpRESS INSTALLATION MANUAL • 6 . s i t e i n s t a l l a t i o n i n s t a l l a t i o n EXHAUST VENT 18" (46cm) 4" (102mm) 4" (102mm) 20" (50cm) MINIMUM 20" (50cm) positioning requirements q in order to ensure proper ventilation, a minimum distance of at least 4-inches (101m...
Page 9 - a c c e s s o r i e s
CT ExpRESS INSTALLATION MANUAL • 7 . a c c e s s o r i e s combiclean® Tablets — ce-28892 sPEcially FOrMulatEd FOr cOMbitHErM OvENs ➥ twO (2) cONtaiNErs / bOX , 90 PackEts EacH cONtaiNEr combitherm cleaning liquid — ce-24750 sPEcially FOrMulatEd FOr cOMbitHErM OvENs ➥ twElvE (12) cONtaiNErs / casE ,...
Page 10 - e s
CT ExpRESS INSTALLATION MANUAL • 8 . water requirements water quality minimum standards ONE (1) COLD WATER INLETS - DRINKING QUALITY ONE (1) WATER INLET: 3/4" g*LINE PRESSURE: 30 to 90 psi 2.8 to 6.2 bar WATER DRAIN: 1-1/2" connecTion wiTh a 2" MiniMuM air gap insTalled as close To The o...
Page 11 - iVH
CT ExpRESS INSTALLATION MANUAL • 9 . water requirements water quality minimum standards ONE (1) COLD WATER INLETS - DRINKING QUALITY ONE (1) WATER INLET: 3/4" g*LINE PRESSURE: 30 to 90 psi 2.8 to 6.2 bar WATER DRAIN: 1-1/2" connecTion wiTh a 2" MiniMuM air gap insTalled as close To The o...
Page 12 - e l e c t r i c a l c o n n e c t i o n; an electrical wiring diagram is located behind
CT ExpRESS INSTALLATION MANUAL • 10. e l e c t r i c a l c o n n e c t i o n i n s t a l l a t i o n d a n g e r ENSURE POWER SOURCE MATCHES VOLTAGE IDENTIFIED ON APPLIANCE RATING TAG. d a n g e r To avoid electrical shock, this appliance MUST be adequately grounded in accordance with local electric...
Page 13 - note
CT ExpRESS INSTALLATION MANUAL • 11 . e l e c t r i c a l c o n n e c t i o n i n s t a l l a t i o n d a n g e r ELECTRICAL CONNECTIONS MUST BE MADE BY A QUALIFIED SERVICE TECHNICIAN IN ACCORDANCE WITH APPLICABLE ELECTRICAL CODES. INTERNAL GROUND STUD CUSTOMER MUST SUPPLY CORD INCOMING ELECTRICAL T...
Page 14 - m o B i l e e q u i p m e n t r e s t r a i n t; Two of the casters must be the locking type.; w a r n i n g; risk of electric shock.; Appliance must be secured
CT ExpRESS INSTALLATION MANUAL • 12 . m o B i l e e q u i p m e n t r e s t r a i n t i n s t a l l a t i o n any appliance that is not furnished with a power supply cord but includes a set of casters, stand with casters, or a stacked configuration must be installed with a tether. adequate means mus...
Page 15 - w a t e r q u a l i t y r e q u i r e m e n t; warning; use a drinking quality, cold water supply only; ALTO-SHAAM COMBITHERM WATER QUALITY MINIMUM STANDARDS; USE A DRINKING QUALITY, COLD WATER SUPPLY ONLY
CT ExpRESS INSTALLATION MANUAL • 13 . i n s t a l l a t i o n w a t e r q u a l i t y r e q u i r e m e n t warning to pREVENt WAtER pIpES FRoM buRStING, INCoMING WAtER SuppLy SHouLd bE tuRNEd oFF WHEN tHE AppLIANCE IS Not IN uSE. warning WAtER SuppLy MuSt bE opEN WHEN CLEANING pRoGRAM IS ACtIVAtEd....
Page 16 - w a t e r c o n n e c t i o n s; water supply & installation; one suggested
CT ExpRESS INSTALLATION MANUAL • 14 . i n s t a l l a t i o n w a t e r c o n n e c t i o n s water supply & installation water requirements one (1) cold water inlet - drinking quality one (1) treated water inlet: 3/4" g line pressure: 30 to 90 psi 2.8 to 6.2 bar REFER TO PUBLISHED SPECIFIC ...
Page 17 - o p t i o n a l h a n d h e l d s p r a y h o s e; Valve bracket; continue to connect an incoming water supply line to the valve.
CT ExpRESS INSTALLATION MANUAL • 15 . i n s t a l l a t i o n o p t i o n a l h a n d h e l d s p r a y h o s e Valve bracket i n s t a l l a t i o n 1 using the valve bracket as a template for placement, and a #28 drill bit (0.14" diameter), drill two holes at the lower rear side of the unit (s...
Page 18 - w a t e r v a l v e
CT ExpRESS INSTALLATION MANUAL • 16 . i n s t a l l a t i o n w a t e r v a l v e w a t e r d r a i n a g e note: the shut-oFF valve must be in the oPen Positionwhen the oven is being used. The oven must discharge through an indirect waste pipe by means of an air gap. The drain fitting is supplied w...
Page 19 - indicator light; v e n t l e s s h o o d m o d e l; filter door latch; o p e r a t i o n; Timed Latching Mechanism: in
CT ExpRESS INSTALLATION MANUAL • 17 . indicator light if the indicator light does not illuminate, the filters may be missing or not properly aligned. check them for proper positioning. Ventless hood and oven will not operate unless the hood is closed properly. i n s t a l l a t i o n v e n t l e s s...
Page 20 - t o p e x h a u s t v e n t
CT ExpRESS INSTALLATION MANUAL • 18 . i n s t a l l a t i o n v e n t l e s s h o o d m o d e l t o p e x h a u s t v e n t 1 Charcoal Filter: The charcoal filter should be inspected for contaminant's on a regular basis. replacement must be made at a minimum of three month intervals — more often if ...
Page 21 - c t e x p r e s s TM c h e c k l i s t; Use this list as a final check of oven installation conformance.; C L E A R A N C E S :; p H y S I C A L C o N d I t I o N : *
CT ExpRESS INSTALLATION MANUAL • 19 . i n s t a l l a t i o n c t e x p r e s s ™ c h e c k l i s t Use this list as a final check of oven installation conformance. Damage directly attributed to improper set up, installation, or cleaning can invalidate warranty claims. C L E A R A N C E S : left: 4&...
Page 22 - error codes; unit is not operating properly, check the; PRESS THE START ICON TO ACKNOWLEDGE THE ERROR.; error call out in display; control error codes
CT ExpRESS INSTALLATION MANUAL • 20. continued on next page error codes this section is provided for the assistance of qualified technicians only and is not intended for use by untrained or unauthorized service personnel. if your alto-shaam ® unit is not operating properly, check the following befor...
Page 24 - see motor control error code list
CT ExpRESS INSTALLATION MANUAL • 22 . error codes error code error call out in display description of error possible cause e34 Steam Generator Drain pump Fault Water level in steam generator does not drop during cleaning program — Scale build up inside the steam generator drain pump . — Scale build ...
Page 27 - o r i g i n a l e q u i p m e n t l i m i t e d w a r r a n t y; THIS WARRANTY DOES NOT APPLY TO:
CT ExpRESS INSTALLATION MANUAL • 25 . o r i g i n a l e q u i p m e n t l i m i t e d w a r r a n t y Alto-Shaam, Inc. warrants to the original purchaser that any original part that is found to be defective in material or workmanship will, at Alto-Shaam’s option, subject to provisions hereinafter st...
Page 28 - t r a n s p o r t a t i o n d a m a g e a n d c l a i m s
t r a n s p o r t a t i o n d a m a g e a n d c l a i m s all alto-shaam equipment is sold F.o.B. shipping point, and when accepted by the carrier, such shipments become the property of the consignee. should damage occur in shipment, it is a matter between the carrier and the consignee. in such case...