Page 3 - D E L I V E R Y; Additional; C A U T I O N; TO PREVENT PERSONAL INJURY,
COMBITOUCH ® ESG SERIES • GAS INSTALLATION MANUAL • MN-29246 • 1. THE INFORMATION CONTAINED IN THIS MANUAL IS IMPORTANT FOR THE PROPER INSTALLATION OF THIS OVEN. PLEASE READ CAREFULLY AND RETAIN FOR FUTURE REFERENCE. IMPROPER CONNECTION OF THIS APPLIANCE WILL NULLIFY ALL WARRANTIES. LES INFORMATIONS...
Page 4 - This appliance is intended to cook, hold; CAUTION
COMBITOUCH ® ESG SERIES • GAS INSTALLATION MANUAL • MN-29246 • 2. C A U T I O N Used to indicate the presence of a hazard that can or will cause minor personal injury, property damage, or a potential unsafe practice if the warning included with this symbol is ignored. C A U T I O N Used to indicate ...
Page 5 - I N S T A L L A T I O N; S I T E I N S T A L L A T I O N; D A N G E R; VENTILATION REQUIREMENTS; See the section titled Gas Exhaust.
COMBITOUCH ® ESG SERIES • GAS INSTALLATION MANUAL • MN-29246 • 3. I N S T A L L A T I O N S I T E I N S T A L L A T I O N INSTALLATION CODES & STANDARDS The following codes and standards are required for installation of this oven: AIR SUPPLY, ELECTRICAL CONNECTIONS, WATER CONNECTIONS, AND WASTE ...
Page 6 - Additional clearance is needed for; To avoid equipment damage, observe
COMBITOUCH ® ESG SERIES • GAS INSTALLATION MANUAL • MN-29246 • 4. I N S T A L L A T I O N S I T E I N S T A L L A T I O N N O T E : Note dimensions required for doorways and aisles for access of the oven and pallet to the installation site. Transport the oven in an upright and level position only. D...
Page 8 - Lifting Instructions; Do not lift in
COMBITOUCH ® ESG SERIES • GAS INSTALLATION MANUAL • MN-29246 • 6. S I T E I N S T A L L A T I O N Lifting Instructions Do not lift in this area! Damage to the components will result. Center of Gravity Front View Top View (Front) Leg 24” Spacer Board Remove banding before lifting. Place a spacer boar...
Page 9 - COMMON SPECIFICATIONS
COMBITOUCH ® ESG SERIES • GAS INSTALLATION MANUAL • MN-29246 • 7. I N S T A L L A T I O N COMMON SPECIFICATIONS q CombiGuard™ BWS Blended Water System FI-28727 (INCLUDES 50 GALLON TANK, 1 MEMBRANE & 3 FILTERS) q CombiGuard™ BWS Replacement Filter Cartridge AMS-QT FI-29316 q CombiGuard™ BWS Repla...
Page 16 - E L E C T R I C A L; Directives; NOTE
COMBITOUCH ® ESG SERIES • GAS INSTALLATION MANUAL • MN-29246 • 14. I N S T A L L A T I O N E L E C T R I C A L An electrical wiring diagram is located behind the control panel on the left side of the oven. This appliance must be branch circuit protected with proper ampacities, in accordance with the...
Page 17 - M O B I L E E Q U I P M E N T R E S T R A I N T; The Standard for Connectors for; W A R N I N G; RISk OF ELECTRIC SHOCk.; Appliance must be secured
COMBITOUCH ® ESG SERIES • GAS INSTALLATION MANUAL • MN-29246 • 15. I N S T A L L A T I O N M O B I L E E Q U I P M E N T R E S T R A I N T The gas Combitherm must use a connector that complies with The Standard for Connectors for Movable Gas Appliances , ANSI Z21.69 CSA 6.16 and addenda Z21.69a-1989...
Page 18 - for an adequate flow of fresh air for gas combustion; flow required to support combustion.; DO NOT; of any obstructions which might retard the flow of
COMBITOUCH ® ESG SERIES • GAS INSTALLATION MANUAL • MN-29246 • 16. I N S T A L L A T I O N VENTILATION REQUIREMENTS An adequate ventilation system is required for commercial cooking equipment. Information may be obtained by writing to the National Fire Protection Association, Batterymarch Park, Quin...
Page 19 - GAS SUPPLY & INSTALLATION; Always remember; GAS SPECIFICATIONS; NATURAL GAS; GAS PRESSURE CHART; TECHNICAL SPECIFICATIONS; Natural Gas; Propane Gas; Min. Connected Pressure
COMBITOUCH ® ESG SERIES • GAS INSTALLATION MANUAL • MN-29246 • 17. I N S T A L L A T I O N GAS SUPPLY & INSTALLATION The Alto-Shaam gas Combitherm has been set to operate with either natural gas or propane as indicated on the identification name plate. Make certain the gas supply matches the nam...
Page 20 - G A S S U P P L Y & I N S T A L L A T I O N; Use
COMBITOUCH ® ESG SERIES • GAS INSTALLATION MANUAL • MN-29246 • 18. I N S T A L L A T I O N G A S S U P P L Y & I N S T A L L A T I O N Remove any tape or compound residue on all external thread connections before proceeding. Use an approved gas pipe sealant at all external threaded connections, ...
Page 22 - NEVER USE AN OPEN; • If unable to contact your gas supplier,
COMBITOUCH ® ESG SERIES • GAS INSTALLATION MANUAL • MN-29246 • 20. I N S T A L L A T I O N GAS SUPPLY & INSTALLATION LEAk TESTING If a pressure leak test above 1/ 2 psi is to be performed on the building supply gas piping, the shut-off gas valve and oven inlet gas supply line must be disconnecte...
Page 23 - WATER SUPPLY & INSTALLATION; WARNINg; high temperature; CONTAMINANT; ALTO-SHAAM COMBITHERM WATER QUALITY MINIMUM STANDARDS; USE A DRINKING QUALITY, COLD WATER SUPPLY ONLY
COMBITOUCH ® ESG SERIES • GAS INSTALLATION MANUAL • MN-29246 • 21. I N S T A L L A T I O N WATER SUPPLY & INSTALLATION WARNINg TO PREVENT WATER PIPES FROM BURSTING, INCOMING WATER SUPPLY SHOULD BE TURNED OFF WHEN THE APPLIANCE IS NOT IN USE. WARNINg WATER SUPPLY MUST BE OPEN WHEN CLEANING PROGRA...
Page 24 - Backflow Prevention —; The use of a pipe; ONE SUggESTEd; CombiGuardTM
COMBITOUCH ® ESG SERIES • GAS INSTALLATION MANUAL • MN-29246 • 22. I N S T A L L A T I O N WATER SUPPLY & INSTALLATION WATER REQUIREMENTS WATER QUALITY MINIMUM STANdARdS TWO (2) COLD WATER INLETS - DRINKING QUALITY ONE (1) TREATED WATER INLET: 3/4" NPT* ONE (1) UNTREATED WATER INLET: 3/4"...
Page 25 - W A T E R V A L V E; Note: Failure to connect
COMBITOUCH ® ESG SERIES • GAS INSTALLATION MANUAL • MN-29246 • 23. I N S T A L L A T I O N W A T E R V A L V E W A T E R d R A I N A g E s h u t - o f f v a l v e s h o w n i n t h e o f f p o s i t i o n NOTE: The shuT-off valve musT be in The oPen PosiTionwhen The oven is being used. A union is re...
Page 26 - W A T E R d R A I N A g E - S T A c k E d
COMBITOUCH ® ESG SERIES • GAS INSTALLATION MANUAL • MN-29246 • 24. Stand Pipe, 1-1/2" NPT (38mm) diameter To Drain - Floor Sink - Air Gap to be within the first 12" (305mm) of the oven drain Drain Connection 1-1/2" NPT (38mm) Air Gap to be within the first 12" (305mm) of the oven dra...
Page 27 - g R E A S E c O L L E c T I O N H O O k - U P; ON; When grease collection is not in use, turn
COMBITOUCH ® ESG SERIES • GAS INSTALLATION MANUAL • MN-29246 • 25. I N S T A L L A T I O N g R E A S E c O L L E c T I O N H O O k - U P ( i f e Q u i p p e D w i t h t h i s f e a t u R e ) • Grease Collection Hose Assembly is attached to the oven in the back. • Place Grease Collection Containers i...
Page 28 - cOMBITOUcH® cHEckLIST; Use this list as a final check of oven installation conformance.; ARE ALL CLEARANCE; WATER SUPPLY AND DRAINS:; ARE BOTH WATER SUPPLY LINES; press the Set-Up Key
COMBITOUCH ® ESG SERIES • GAS INSTALLATION MANUAL • MN-29246 • 26. cOMBITOUcH® cHEckLIST Use this list as a final check of oven installation conformance. Damage directly attributed to improper set up, installation, or cleaning can invalidate warranty claims. CLEARANCES: ARE ALL CLEARANCE REQUIREMENT...
Page 29 - unit is not operating properly, check the; PRESS THE START ICON TO ACKNOWLEDGE THE ERROR.; Error call Out in display; E R R O R c O d E S
COMBITOUCH ® ESG SERIES • GAS INSTALLATION MANUAL • MN-29246 • 27. I N S T A L L A T I O N This section is provided for the assistance of qualified technicians only and is not intended for use by untrained or unauthorized service personnel. If your Alto-Shaam ® unit is not operating properly, check ...
Page 31 - ERROR cOdES; No Water In Boiler; 0•20 lower fan motor too hot; See Motor control Error code list; Vent Not Open
COMBITOUCH ® ESG SERIES • GAS INSTALLATION MANUAL • MN-29246 • 29. I N S T A L L A T I O N ERROR cOdES Error code Error call Out in display description of Error Possible cause E34 Steam Generator Drain Pump Fault Water level in steam generator does not drop during cleaning program — Scale build up i...
Page 32 - No Rinse Water
COMBITOUCH ® ESG SERIES • GAS INSTALLATION MANUAL • MN-29246 • 30. see motor control error chart on next page I N S T A L L A T I O N ERROR cOdES Error code Error call Out in display description of Error Possible cause E57 No Rinse Water During rinse no water fl ow is detected through solenoid valve...
Page 33 - Type of Error; combiTouch MOTOR cONTROL ERROR cOdES
COMBITOUCH ® ESG SERIES • GAS INSTALLATION MANUAL • MN-29246 • 31. I N S T A L L A T I O N Type of Error Indication Release of Error Undervoltage LED fl ashing sequence, with 1 fl ash per period. Voltage of intermediate circuit is less than 250V Overvoltage LED fl ashing sequence, with 2 fl ashes pe...
Page 35 - O R I g I N A L E Q U I P M E N T L I M I T E d W A R R A N T Y; THIS WARRANTY DOES NOT APPLY TO:
COMBITOUCH ® ESG SERIES • GAS INSTALLATION MANUAL • MN-29246 • 33. O R I g I N A L E Q U I P M E N T L I M I T E d W A R R A N T Y Alto-Shaam, Inc. warrants to the original purchaser that any original part that is found to be defective in material or workmanship will, at Alto-Shaam’s option, subject...
Page 36 - T R A N S P O R T A T I O N d A M A g E A N d c L A I M S
COMBITOUCH ® ESG SERIES • GAS INSTALLATION MANUAL • MN-29246 • 34. W164 N9221 Water Street • P.O. Box 450 • Menomonee Falls , Wisconsin 53052-0450 • U.S.A. PHONE: 262.251.3800 • 800.558-8744 USA/CANADA FAX: 262.251.7067 • 800.329.8744 U.S.A. ONLY www.alto-shaam.com All Alto-Shaam equipment is sold F...